§ 9.4 — Standards by Frontage Type
Santa Clara City Code (Title 18, Zoning, July 2025 edition; partial) · Santa Clara City Code ch. 18.26, Downtown Form-Based Code § 9.4
Corpus is an independent public-information project, not the official City of Santa Clara website. Stable reference: corpuslaw.us/code/6940ad56-85d9-4803-9a96-9392ed682543
The following pages provide standards for the 6 allowed private frontage types in Downtown. The standards specific to each frontage type apply wherever such type occurs. 9.4.A. SHOPFRONT Shopfronts are characterized by large ground floor openings, including windows and entries, which provide transparency and connection between the public realm and ground floor uses such as shops and restaurants. The primary entrance is typically at sidewalk grade, unless ADA accessibility is accomplished by other means, and provides direct access to the ground-floor use. The basic architectural elements comprising the storefront are large clear windows, doors with glass, and transom windows. If shopfronts have a setback, the setback is typically treated as an extension of the sidewalk. Design Standards 1. Shopfront openings shall be organized into bays, with upper floor windows stacked above, per the standards in Section 8.A.2. 2. If a shopfront is recessed or otherwise setback, and is not designed in combination with a Dooryard, Terrace, or Porch (as allowed in Section 10), the resulting setback shall be designed as a seamless continuation of the sidewalk, not as a landscaped area or buffer. Where permitted, this area may be used for outdoor dining, merchandising and potted plants. 3. Shopfronts shall provide for commercial kitchen infrastructure, regardless of the initial planned use of the Shopfront. New development shall provide— or demonstrate on submitted plans that adequate space is provided—for a commercial grease trap and chase(s) for kitchen venting adequate to support a standard full-size restaurant. 4. A shopfront may accommodate small-format automobile showrooms, provided they function as would any other retail shopfront. FIGURE 9-2 | SHOPFRONT Design Guidelines 5. Where permitted, shopfronts may be used in combination with Galleries or Arcades, or where the setback is sufficient and context is appropriate, in combination with a Dooryard, Terrace, or Porch (see Section 10 for Architectural Projections). 6. Ground floor windows should have a minimum transparency of 80% and an external reflectance of less than 15%. 7. All shade should be provided on the exterior of the building; the majority of the interior space should be visible from the right of way. 8. With minor exceptions, all shopfront openings should provide visibility into the interior space, and not be visually obstructed by signage, merchandising racks, storage shelves, etc. 9. Window sills of non-entry bays shall be no higher than 2 feet from adjacent sidewalk grade. TABLE 9-3 | SHOPFRONT
| Design Standards | MIN | MAX | |---|---|---|
A B
| Height to top of transom | 12’ | - | |---|---|---| | Height of shopfront base | 1' | 2' | | Depth of commercial space | 50’ 1 |
Notes 1 Exception: Spaces for local non-formula retail and restaurant establishments shall have a minimum depth of 30'. 9.4.B. COMMON ENTRANCE Common entrances, like shopfronts, should have a strong connection to the public realm. While not always open to the wider public, they are spaces that are shared by all tenants which rely on them for building access. Access to individual units (ground and upper floors) is provided via a shared hall/corridor within the building. Design Guidelines 1. Common entrances should be conspicuous and designed as a focal-point of the ground-floor facade. Designs that engage multiple floors and/ or help modulate the facade of the main building are encouraged (See also Sections 7 and 8 for Building Massing and Facade Design). 2. Entry spaces within common entrances should be visible from the public right of way. Ground floor windows shall have a transparency higher than eighty percent and an external reflectance of less than fifteen percent. Window sills may be no higher than 2 feet from adjacent grade. All shade should be provided on the exterior of the building. See Section 8.2.C for more fenestration requirements. 3. In some cases, a Common Entrance may include or be combined with a semi-private yard or open space to provide a comfortable, attractive outdoor public transitional space that allows congregation off of the sidewalk, standards for which are provided in Section 13 Site Standards. 4. Common entrances may also be used with a Porch, Dooryard, Terrace, Arcade, or Gallery where allowed (See Section 10 Architectural Projections). FIGURE 9-3 | COMMERCIAL COMMON ENTRANCE FIGURE 9-4 | RESIDENTIAL COMMON ENTRANCE TABLE 9-4 COMMON ENTRY
| Design Standards | MIN | MAX | |---|---|---|
| Height to top of transom | 10’ | 20’ | |---|---|---| | Height to bottom of canopy/awning | 8’ | - | | Distance to back of sidewalk | - | 20’ | | Area of outdoor space1 | 80 sf | - | | Awning/Canopy Depth | See §10.4.G |
A B C Notes 1 Does not include public R.O.W. 9.4.C. RETAIL/HOUSING FLEX Retail/Housing Flex frontage is a versatile type that can host residential uses in the near-term and be easily converted into shopfronts in the future if the market improves for commercial uses. Design Standards 1. This type is only allowed in the General Overlay (see Fig. 4-2), as residential is not allowed in the Shopfront and Retail-Ready Overlays. Design Guidelines 2. The ground floor fenestration amount should be between 65% and 95%. 3. The setback should be designed and landscaped to provide privacy when the frontage hosts uses which require privacy, such as residences or offices. 4. When in residential use, ground floor bedroom and bathrooms windows are prohibited along the front facade. 5. When in retail use, if a dooryard or terrace is not used and the entry is at ground level, the setback is typically treated as an extension of the sidewalk. 6. When in retail use, the ground floor fenestration should be transparent and provide visibility to the interior spaces per Section 9.4.A Shopfronts. FIGURE 9-5 | FLEX DOORYARD FIGURE 9-6 FLEX TERRACE 9.4.D. GROUND FLOOR OFFICE The private frontages of ground floor offices, where allowed in Downtown, must be carefully designed to ensure that they appropriately contribute to the active public realm environment of downtown. Like ground floor residential, they typically require some level of privacy, but they still have the opportunity to give life to the street. Design Standards 1. Ground-floor office uses in the Retail-Ready Overlay shall be designed as Shopfront frontages. 2. Fenestration shall be calibrated according to overlay. See Section 8.2.C for more information. Design Guidelines 3. In general, the most public-friendly office functions such as reception and waiting area or office amenity space should be located closest to the primary facade. Areas for private functions, such as examination rooms, should not be located on the primary facade. 4. Ground floor offices may take access directly from the sidewalk and/or from a Common Entrance or Lobby (See Section 9.4.B). 5. The setbacks of ground floor offices at or near the level of the sidewalk may feature a dooryard or simple landscaping, or they may be designed as extensions of the sidewalk if privacy is not desired. Raised ground floor offices may use a Terrace, Porch, or Stoop. See Section 10 Architectural Projections. FIGURE 9-7 | OFFICE WITH COMMON ENTRANCE / MULTIPLE FLOOR LOBBY FIGURE 9-8 | OFFICE WITH COMMON ENTRANCE TABLE 9-5 | COMMON ENTRANCE / LOBBY
| Design Standards | MIN | MAX | |---|---|---| | A | Height to top of transom | 10’ | 20’ | | B | Height to bottom of canopy/awning | 8’ | - | | | Distance to back of sidewalk | - | 20’ | | | Area of outdoor space1 | 80 sf | - | | C | Awning/Canopy Depth | See §10.4.G |
Notes 1 Does not include public R.O.W. 9.4.E. GROUND FLOOR RESIDENTIAL Ground Floor Residential frontages provide a transition from the public sidewalk to semi-private or private space. These frontages moderate the privacy needs of the residential unit with the need to provide eyes on the street to ensure a safe and activated public realm environment. Accordingly, the closer the ground floor facade is to the street, the more carefully designed the frontage must be. Ground floor units are either entered through a common entry (such as an entry lobby or shared private court) or directly from the public sidewalk, typically through a transitional entry element such as a dooryard, porch, terrace, or stoop. Design Standards 1. If the setback is less than 10 feet, residential ground floors shall have a first floor level that is 3' to 4' above the level of the sidewalk, unless the unit is designed to be ADA accessible or Retail-Ready. If the setback is 10 feet or greater, residential ground floors should have a first floor level that is 1.5' to 4' above the level of the sidewalk, but may have a first floor level at or near the level of the sidewalk. 2. For required residential setback requirements see Section 5 and Table 5-1 Building Placement. 3. See Section 8.2.C and Table 8-1. Fenestration for residential fenestration standards. 4. Ground floor bedroom windows are prohibited along the primary facade. 5. Ground floor and second floor bathroom windows are prohibited along the primary facade. Bathrooms along the primary facade above the second floor are permitted, provided that their windows match the appearance, sill height, and lintel height of the other windows on the facade and meet the general fenestration standards of Section 8.2.C. FIGURE 9-9 | GROUND FLOOR FRONTAGES AND ENTRY TYPE VARIATIONS DIRECT ENTRY TYPES—Dooryards (left) and Terraces (right) COMMON ENTRY—Shared access into a lobby 6. If access to ground floor units is directly from the public sidewalk, entry may be provided via a Dooryard, Terrace, Porch, or Stoop. See Section 10 Architectural Projections. 7. If direct access is not provided, entry may be via a Common Entry with shared passageways. Design Guidelines 8. Windows on ground floor residential are typically similar to those found on upper floors of the facade. 9. Privacy Modulation. The distance from the sidewalk to the facade and first floor windows is used to maintain a balance between resident comfort level and neighborhood security and activity. The closer a residential unit is to the sidewalk, the higher the ground RAISED GROUND FLOORS—The raised elevation of the ground floor from sidewalk level, and taller ground floor sill heights (generally above eye-level), allow residents to overlook the street outside, while preventing passers-by from seeing into private interior spaces. floor elevation should be to maintain a sense of privacy. See Table 6-2 for ground floor height standards. However, this height is affected by ground floor fenestration standards. See Section 8-1 for more information. PRIVACY MODULATION EXAMPLES SHALLOW SETBACK (VERY URBAN CONDITION)—The facade is close to the sidewalk (less than 5ft), so the unit's ground floor is raised high enough that pedestrians must look up to see into the interior. The opaque front door and the landscaping is used to ensure privacy. However, the lower bushes and ground cover soften the wall in a nod to the neighborhood context. COMFORTABLE SETBACK/ELEVATION (TYPICAL URBAN CONDITION)—The combination of modest setbacks and ground floor elevation - in the form of semi-private dooryard/terraces - provides sufficient privacy and a comfortable buffer between the sidewalk and large glass openings of the living room, with more private bedrooms on the second floor. NO SETBACK (ATYPICAL URBAN CONDITION)—The facade is immediately at the back of walk, but window sill height is above eye level of the passerby, maintaining privacy within the unit while allowing the tenant to overlook the street. GENEROUS SETBACK (LESS URBAN CONDITION)— These ground-floor units are at-grade with the sidewalk, with low sill-height. In this case, generous landscape setbacks (15ft) provide a sufficient privacy buffer from the street allowing residents to look out onto the public realm. 9.4.F. VEHICULAR ACCESS Vehicular Access frontages typically provide access to parking garages or through a building to rear service areas or surface parking. Because of their utilitarian nature, their design is often neglected. However, they require particular care in their design as their sheer size and presence along the street wall can make them one of the most disruptive elements to the quality of the pedestrian environment. Design Standards 1. For standards related to parking structure facades, see Section 8.2.D. 2. Vehicular Access frontage on a street is only allowed when no alley provides access to the lot. The provision of alleys makes higher quality frontages possible and are highly encouraged. 3. Vehicular entries shall be organized into openings that are proportioned and detailed to look appear similar to Shopfronts (Section 9.4.A). These openings shall be organized into vertical bays in coordination with the overall facade per Standard 8.2.A.2. 4. Vehicular Access openings shall be no more than 13 feet wide. Where adjacent openings are necessary to provide entry and exit, they shall be separated by a pier (a portion of wall) of at least 2 feet in width. 5. Vehicular Access frontage may comprise no more than 40% of a building's required buildout (per Table 5–1 in Section 5.3), and a single project may have no more than 2 Vehicular Access openings on any one street. FIGURE 9-11 | VEHICULAR ACCESS: DESIRABLE DESIGNS
Shopfronts
VEHICULAR ACCESS can be organized into attractive, well-proportioned bays, just like shopfronts. 6. Gates which open to allow cars to enter (excluding security doors that are shut when the garage is not accessible) shall be inset from the facade by a minimum of 20 feet, to allow cars to await entry without blocking the sidewalk. FIGURE 9–12 | VEHICULAR ACCESS
| Design Standards | MIN | MAX | |---|---|---| | A | Width of Opening | - | 13’ | | B | Width of pier/wall between openings | 2’ | - | | C D | Percentage of building's required frontage (C divided by D) | - | 40% | | E | Gate inset into building | 20’ | - |
7. Entries should be at least 50 feet from the corner of a block. 8. Gates or doors which secure vehicular entries should be designed as attractive urban elements, just like pedestrian entry doors. 9. Parking counters are recommended in all parking garages with public access.
Ask a question about Santa Clara law
Corpus searches the Santa Clara sections it holds and shows the ones that match, with their citations. Free, no sign-in.
