§ 14.04.420 — Section R606.12.2.2.3 of the 2025 Edition of the California Residential Code is amended to read as follows
Pasadena Municipal Code, California (Supp. No. 79: codified through Ordinance No. 7469, enacted May 18, 2026) · Pasadena Municipal Code § 14.04.420
Corpus is an independent public-information project, not the official City of Pasadena website. Stable reference: corpuslaw.us/code/69cca653-a2fb-498f-bcde-2cd1c65a2231
14.04.420 - Section R606.12.2.2.3 of the 2025 Edition of the California Residential Code is amended to read as follows.
R606.12.2.2.3 Reinforcement requirements for masonry elements. Masonry elements listed in Section R606.12.2.2.2 shall be reinforced in either the horizontal or vertical direction as shown in Figure R606.11(2) and in accordance with the following: 1. Horizontal reinforcement. Horizontal joint reinforcement shall consist of not less than one No. 4 bar spaced not more than 48 inches (1219 mm). Horizontal reinforcement shall be provided within 16 inches (406 mm) of the top and bottom of these masonry elements. 2. Vertical reinforcement. Vertical reinforcement shall consist of not less than one No. 4 bar spaced not more than 48 inches (1219 mm). Vertical reinforcement shall be within 8 inches (406 mm) of the ends of masonry walls.
(Ord. No. 7461, § 5, 11-10-2025)