§ 260 — Flood resistant development; buildings and structures
Land Development Code, City of Coral Springs, Florida (Supp. No. 76, Update 2: codified through Ordinance No. 2025-119, enacted December 3, 2025) · Coral Springs Land Development Code § 260
Corpus is an independent public-information project, not the official City of Coral Springs website. Stable reference: corpuslaw.us/code/6b1bb670-4c34-4299-a970-bc0c4708bfce
Sec. 260. - Flood resistant development; buildings and structures.
(1) Design and construction of buildings, structures and facilities exempt from the Florida Building Code. Pursuant to section 255(3) of this article, buildings, structures, and facilities that are exempt from the Florida Building Code, including substantial improvement or repair of substantial damage of such buildings, structures and facilities, shall be designed and constructed in accordance with the flood load and flood resistant construction requirements of ASCE 24. Structures exempt from the Florida Building Code that are not walled and roofed buildings shall comply with the requirements of section 266 of this article. (2) Specific methods of construction and requirements. Pursuant to Broward County Administrative Provisions for the Florida Building Code, the specific methods of construction and requirements in section 260(3) and 260(4) apply. (3) Building and structure elevation requirements. Within the City of Coral Springs, stormwater/drainage management facilities and services are provided by the city and five (5) water control/improvement districts: the Coral Springs Improvement District (CSID), the Sunshine Water Control District (SWCD), the North Springs Improvement District (NSID), the Pine Tree Water Control District (PTWCD), and the Turtle Run Community Development District (TRCDD). Before any project may be approved by the city, an applicant must obtain certification from the appropriate water control/improvement district that the proposed improvements meet all of the district's applicable design and construction standards. The South Florida Water Management District (SFWMD) has established the minimum finished floor elevations for drainage basins that comprise the water control improvement districts. The SFWMD elevations are potentially more restrictive than FEMA elevations. The elevation of the lowest floor, or elevation of dry floodproofing, shall be established by the higher and more restrictive of the following: (a) For all building and structures, the elevations required by the Florida Building Code, Building or the Florida Building Code, Residential. (b) For one- and two-family dwellings, townhouses, and manufactured homes, eighteen (18) inches above the crown of the street or road abutting the property. (c) For buildings and structures other than one- and two-family dwellings, townhouses, and manufactured homes, six (6) inches above the crown of the street or road abutting the property. (d) The elevations specified by the water control districts, adjusted to the datum shown on the FIRM. The following table is presented for informational purposes to summarize the elevations (based on National Geodetic Vertical Datum of 1929) specified by the water management districts. West Basin | East Basin | Basin within City NSID | 12.2 | 13.0 | N/A SWCD | 11.5 | 12.5 | N/A CSID | 11.5 | 12.0 | N/A PTWCD | N/A | N/A | 16.2 TRCDD | N/A | N/A | 16.2 (4) Limitations on enclosed areas below elevated buildings. For buildings and structures in special flood hazard areas, the following limitations apply to enclosed areas below elevated buildings: (a) Access shall be the minimum necessary to allow for only parking of vehicles (garage door), limited storage of maintenance equipment in connection with the premises (standard exterior door), or entry to the living area (stairway or elevator). (b) The interior portion shall not be temperature controlled, partitioned, or finished into separate rooms. (5) Accessory structures. Accessory structures are permitted below the base flood elevation provided the accessary structures are used only for parking or storage; and (a) Are one story and not larger than six hundred (600) square feet. (b) Have flood openings in accordance with Section R322.2 of the Florida Building Code, Residential. (c) Are anchored to resist flotation, collapse or lateral movement resulting from flood loads. (d) Have flood damage-resistant materials used below the base flood elevation plus one (1) foot. (e) Have mechanical, plumbing and electrical systems, including plumbing fixtures, elevated to or above the base flood elevation plus one (1) foot.
(Ord. No. 2014-113, § 3, eff. 6-18-14; Ord. No. 2021-106, § 2, 4-21-21)
Ask a question about Coral Springs law
Corpus searches the Coral Springs sections it holds and shows the ones that match, with their citations. Free, no sign-in.
