§ 17.85.420 — Improvement pathways: Properties requiring additional energy or water efficiency
San José Municipal Code (Supp. No. 5: codified through Ordinance No. 31341, enacted August 25, 2026) · San José Municipal Code § 17.85.420
Corpus is an independent public-information project, not the official City of San Jose website. Stable reference: corpuslaw.us/code/6bda298e-e648-4eb2-95cb-079acd5e9fd7
17.85.420 - Improvement pathways: Properties requiring additional energy or water efficiency.
If a Property does not meet performance standards set forth in Section 17.85.400 above, an Owner shall meet the requirements of this Chapter through one (1) of three (3) alternative means: (1) Conducting an Audit; (2) Performing Retro-Commissioning; or (3) Adopting Efficiency Improvement Measures. A. Improvement Pathway 1: Audit An Owner may comply with the requirements of this Chapter by conducting an Audit by a Qualified Auditor for any unmet Energy or water standard and submitting an Audit Report within the time set forth in Part 5. 1. Audit Requirements: An Owner may comply with the requirements of this Chapter by performing an Audit by a Qualified Auditor as verified in an Audit Report. Such Audit shall comply with the following: a. Energy Audit: The Energy Audit required by this Chapter shall meet or exceed the following: i. Level 2 Audit standards in conformance with the American Society of Heating Refrigerating and Air-Conditioning Engineers ("ASHRAE") Standard 211-2018: Standard for Commercial Building Energy Audits (latest edition at the time the Audit is initiated); or ii. An Energy assessment or Audit offered by the utilities serving the Property, provided that the potential savings opportunities related to all Energy sources are evaluated. b. Water Audit: The Water Audit required by this Chapter shall be performed in accordance with industry standard practices. Until such time as a third party verifiable water auditing process is developed and endorsed by a professional building association, governmental entity, or academic institution, and as approved by the Director of the Department, Water Audit of the Base Building Systems shall include, at a minimum, the following: i. Potable water distribution systems; ii. Landscape irrigation systems; iii. Water reuse systems; and iv. Water features. 2. Audit Report: A report of the Audit, completed and signed by Qualified Auditor, shall be submitted to the City and maintained by the Owner as required in Section 17.85.500. The report shall meet the requirements of Section 17.85.410 and shall include, at a minimum, the following: a. The date(s) that the Audit was performed; b. Identifying information on the auditor; c. Information on the Base Building Systems and equipment; d. A list of all Retrofit Measures that can reduce Energy or Water use, or cost of operating the Property, costs of each measure, and an estimate of the Energy and/or Water savings associated with each measure; e. Acknowledgment that an ASHRAE Level 2, or alternate approved assessment or audit was conducted; and f. Identification of existing electric vehicle charging stations, equipment, and infrastructure, as defined in Article 625 of the California Electric Code, including: i. Number of existing electrical charging stations; and ii. Number of "EV Capable" parking spaces as defined in California Green Building Standards (CalGreen) Sections 5.106.5.3.3 (Non-residential) and 4.106.4.2 (Residential) or as thereafter amended; or if no "EV Capable" parking spaces are present, number of 40-ampere minimum branch circuit capacity within the nearest circuit panel to existing parking spaces. B. Improvement Pathway 2: Retro-Commissioning An Owner may comply with the requirements of this Chapter by performing Retro-Commissioning under the direct supervision of a Qualified Retro-Commissioning Professional for any unmet Energy or water standard and submitting a Retro-Commissioning Report within the time set forth in Part 5. Such Retro-Commissioning shall comply with the following: 1. Energy Retro-Commissioning. Energy Retro-Commissioning shall be performed in accordance with industry standard practices, including ASHRAE Guideline 0.2, Commissioning Process for Existing Systems and Assemblies, and other standards as may be defined by the Director of the Department. a. The Retro-Commissioning of the Base Building Systems shall ensure that all systems are maintained, cleaned and repaired, HVAC temperature and humidity set points and setbacks are appropriate, operating schedules reflect major space occupancy patterns and the current facility requirements, and that all operating parameters are adjusted to achieve efficient operations; and b. The Retro-Commissioning shall include, at minimum, the following: i. Heating, ventilation, air conditioning (HVAC) systems and controls; ii. Indoor lighting systems and controls; iii. Water heating systems; and iv. Renewable Energy system. 2. Water Retro-Commissioning: Water Retro-Commissioning shall be performed in accordance with industry standard practices, such as ASHRAE Guideline 0.2, Commissioning Process for Existing Systems and Assemblies, or other standards as may be defined by the Director of the Department. The Retro-Commissioning of the Base Building Systems shall include, at minimum, the following: a. Potable water distribution systems; b. Landscape Irrigation Systems; c. Water Reuse Systems; and d. Water Features. 3. Retro-Commissioning Report: A Retro-Commissioning Report, completed and signed by a Qualified Retro-Commissioning Professional, shall be submitted to the Department and maintained by the Owner as required in Section 17.85.500. The report shall meet the requirements of this Chapter, and shall include, at a minimum, the following: a. The date(s) that the Retro-Commissioning was performed; b. Identifying information for the Retro-Commissioning provider; c. Information on the Base Building Systems and equipment both before and after the Retro-Commissioning; and d. All the Retro-Commissioning process activities undertaken, and Retro-Commissioning Measures completed. C. Improvement Pathway 3: Efficiency Improvement Measures An Owner of a Property which does not have a central cooling system may comply with the requirements of this Chapter for any unmet standard by demonstrating two (2) of the following corresponding efficiency improvement measures listed below were completed and submitting an Efficiency Improvement Measures Report within the time set forth in Part 5. 1. Energy Efficiency Improvement Measures: a. Installation of common area and exterior lighting fixtures in accordance with California Building Standards Code (California Code of Regulations, Title 24) requirements in effect at the time of the compliance cycle; b. Installation of domestic hot water heater in accordance with California Building Standards Code (California Code of Regulations, Title 24) requirements in effect at the time of the compliance cycle; c. Replacement of all refrigerators on the Property to ENERGY STAR® Certified models; d. Replacement of all gas stoves on the Property to electric induction stoves; e. Replacement of all gas water heaters on the Property to electric heat pump or tankless water heaters; f. Installation of a smart thermostat; g. Installation of a solar thermal heating/cooling system; h. Enrollment in a Department-approved utility demand response program; i. Installation of insulation on all hot water pipes in accessible Property locations; or j. Participation in a Department-approved Energy utility retrofit program (e.g., taken advantage of rebate or incentive programs for upgrades). 2. Water Efficiency Improvement Measures a. Installation of plumbing such that all systems on the Property are in compliance with California Building Standards Code (California Code of Regulations, Title 24) requirements in effect at the time of the compliance cycle; b. Installation of outdoor landscaping and irrigation such that all systems on the Property are in compliance with San José Municipal Code Chapter 15.11, Water Efficient Landscape Standards for New and Rehabilitated Landscaping in effect at the time of the compliance cycle; c. Installation of a greywater system in accordance with California Code of Regulations, Title 24, Sections 1502.6, 1502.10.3, or as amended; d. Installation of insulation on all hot water pipes in accessible Property locations; or e. Participation in approved water utility retrofit program (e.g., taken advantage of rebate or incentive programs for upgrades). 3. Efficiency Improvement Measures Report: A report of the Efficiency Improvement Measures implemented shall be submitted to the City and maintained by the Owner as required in Section 17.85.500. The report shall be submitted with sufficient supporting data including receipts or other proof of compliance and shall include, at a minimum, the following: a. Descriptions of the measures including the date(s) that the Efficiency Improvement Measures were implemented; b. Identifying information on the person implementing the Efficiency Improvement Measures; c. Information on the Base Building Systems and equipment; and d. A list of all Efficiency Improvement Measures that can reduce Energy or Water use and the cost of operating the Property, and the costs of each measure.
(Ords. 30197, 30550, 31187.)
Ask a question about San Jose law
Corpus searches the San Jose sections it holds and shows the ones that match, with their citations. Free, no sign-in.