Sec. 5.11.15. - Alternative Energy.
A. Wind Energy Systems. For the purposes of this Section, an "On Site Use Wind Energy System" is intended to primarily serve the needs of the consumer, but may be connected to the utility grid under certain circumstances. "Utility Grid Wind Energy Systems" are intended to serve the needs of the community and are connected to the utility grid. Applicable screening and buffering requirements shall apply. Wind energy systems are permitted as an accessory use in all districts, subject to the requirements of Table 5.11.15.A.
Table 5.11.15.A. Wind Energy Systems
Zone Districts | System Type/Height | Review Process | Setback and Tower Height
Counter Review 5.12.09 | Director Review 5.12.10.
All | On site use wind energy system tower | Under 60 ft. | Required | — | See Sections 5.11.15.A.1 and 11.15.A.2. for the maximum height permitted for the Zone District; bonus heights may be included. No height limit on properties larger than 3 acres, subject to FAA regulations
60 ft. or more | — | Required
Anemometer Tower | Under 60 ft. | Required | —
60 ft. or more | — | Required
SD-OS; SD-IT; SD-IC | Utility Grid Wind Energy System | — | Required
1. Setbacks. No part of the wind system structure, including guy wire anchors, shall extend closer than ten (10) feet to the lot lines of the installation site. Where property is located on both sides of a public right-of-way, a wind energy system may be placed no closer than one (1) rotor radius from the closest edge of the right-of-way.
2. Tower Height.
a. Tower height shall be defined as the total height from grade to the highest extent of any equipment, including roof-mounted systems. For roof-mounted systems, the height shall be measured from the connection point on the roof.
b. The height of tower-mounted systems is limited by the size of the property upon which they are constructed. A circular fall zone with a radius of one and two-tenths (1.2) times the total height of the system must be completely contained within the property. For roof-mounted systems, a circular fall zone with a radius of one and one-half (1.5) times the system height must be completely contained within the property.
c. For the purposes of cooperative wind energy sharing, two (2) or more properties may combine to allow greater system height.
i. This arrangement shall be subject to Director Review of Section 5.12.16., or may be subject to Special Land Use procedures, at the discretion of the Director.
ii. Properties entering into a cooperative arrangement must record a permanent cross-access easement with the Kent County Register of Deeds and provided a recorded copy to the Planning Department, describing the terms of the arrangement, and a survey of all properties showing the proposed location of the wind tower(s) and associated fall zones. The easement language must also be included with the title and property survey of all properties entered into the cooperative.
iii. Any sharing of energy produced by a wind energy system operated under the terms of a cooperative agreement as described in this Section may be subject to state utility regulations.
3. Historic Districts. Wind energy systems in a designated Historic District or Historic Landmark shall be subject to the review and approval of the Historic Preservation Commission.
4. SCADA (Supervisory Control and Data Acquisition) or Met (Meteorological) Towers. SCADA and Met towers shall comply with the setback requirements of this Section. An operations and maintenance office building, sub-station, or related equipment or structures shall comply with any applicable requirements of the Zone District.
5. Construction Codes, Towers, and Interconnection Standards. Utility systems including towers shall comply with all applicable state construction and electrical codes and local building permit requirements, Federal Aviation Administration requirements, the Michigan Airport Zoning Act (Public Act 23 of 1950, MCL 259.431 et seq.), the Michigan Tall Structures Act (Public Act 259 of 1959, MCL 259.481 et seq.), applicable utility, Michigan Public Service Commission, and Federal Energy Regulatory Commission interconnection standards. The minimum FAA lighting standards shall not be exceeded. All tower lighting required by the FAA shall be shielded to the extent possible to reduce glare and visibility from the ground.
6. Safety.
a. An On-Site Use Wind Energy System shall have an automatic braking, governing, or feathering system to prevent uncontrolled rotation or over speeding. All wind towers shall have lightning protection. If a tower is supported by guy wires, the wires shall be clearly visible to a height of at least six (6) feet above the guy wire ground anchors.
b. All Utility Grid Wind Energy Systems shall be designed to prevent unauthorized access to electrical and mechanical components and shall have access doors that are kept securely locked at all times when service personnel are not present. All waste lubricants and cooling fluids shall be properly and safely removed in a timely manner from the site of the wind energy system.
c. Safety Signs. A sign shall be posted near the tower or operations and maintenance office building that shall contain emergency contact information. Signs shall be placed at the street access to warn visitors about the potential danger of falling ice. These signs shall be in addition to any signs allowed in Article 15.
d. The minimum vertical blade tip clearance from grade shall be twenty (20) feet for a wind energy system employing a horizontal axis rotor.
7. Visual Effect. A Utility Grid Wind Energy System project shall use tubular towers and all systems shall be finished in a single, non-reflective matte finish of similar design, size, operation, and appearance and, to the extent possible, shall be integrated into the architectural character of the main building. The applicant shall avoid state or federal scenic areas and significant visual resources listed in the Master Plan or in local, state or federal historic registers.
8. Environmental Impact.
a. The applicant shall have a third party, qualified professional conduct an analysis to identify and assess any potential effects on the natural environment including, but not limited to, wetlands and other fragile ecosystems, historical sites and birds and wildlife. The applicant shall take appropriate measures to minimize, eliminate or mitigate adverse effects identified in the analysis.
b. The applicant shall identify and evaluate the significance of any net effects or concerns that shall remain after mitigation efforts. The applicant shall comply with applicable parts of the Michigan Natural Resources and Environmental Protection Act (Act 451 of 1994, MCL 324.101 et seq.).
9. Noise. Small wind energy systems shall not exceed sixty (60) decibels, measured at the closest residential dwelling. This level may be exceeded during short-term events such as utility outages or storms.
10. Electromagnetic Interference.
a. A Utility Grid Wind Energy System shall not be installed in any location where its proximity to existing fixed broadcast, retransmission, or reception antennas for radio, television, or wireless phone or other personal communication systems would produce electromagnetic interference with signal transmission or reception unless the applicant provides a replacement signal to the affected party that shall restore reception to at least the level present before the operation of the wind energy system.
b. A Utility Grid Wind Energy System shall not be installed in any location within the line of sight of an existing microwave communications link where operation of the wind energy system is likely to produce electromagnetic interference in the link's operation, unless the interference is insignificant.
11. Shadow Flicker. The applicant shall conduct an analysis on potential shadow flicker at occupied structures. The analysis shall identify the locations of shadow flicker that may be caused by the project and the expected durations of the flicker at these locations from sunrise to sunset over the course of a year. The analysis shall identify problem areas where shadow flicker may affect the occupants of the structures and describe measures that shall be taken to eliminate or mitigate the effects.
12. Signs shall meet the requirements of Article 15.
B. Solar Energy Systems.
1. Accessory Use. Solar energy systems are permitted as an accessory use in all Zone Districts.
2. General Requirements.
a. Solar energy equipment shall be repaired, replaced, or removed within three months of becoming nonfunctional.
b. All panels shall have tempered, non-reflective surfaces.
c. Each system shall conform to applicable industry standards including those of the American National Standards Institute (ANSI).
d. Solar energy collectors shall be installed, maintained, and used only in accordance with the manufacturer's specifications.
3. Placement.
a. Solar collection systems shall be placed so as not to adversely affect the pleasure and enjoyment of nearby residential uses.
b. Ground-mounted equipment. Ground mounted equipment for the collection of solar energy is permitted to the side or rear of the main building, but not within five (5) feet of a side or rear property line, shall be otherwise sited to minimize view from the public right-of-way and adjacent properties, and shall be camouflaged to the extent that the equipment can function normally.
c. Rooftop equipment. Rooftop equipment for the collection of solar energy may be installed on the roof of a main or accessory structure, including carports or similar structures, when:
i. The panels do not extend more than two (2) feet above the height of the structure upon which it is placed.
ii. The panels do not project beyond the eaves of the roof.
iii. The panels are integrated, to the extent possible, with the architectural character of the building or structure on which the equipment is affixed. No unfinished lumber is permitted.
4. Administrative Departure. An Administrative Departure may be approved for a location not meeting the requirements of this Section after considering the following:
a. Potential on-street glare from the solar energy system;
b. Alternative on-site locations, and;
c. The extent to which neighborhood character may be compromised.
5. Connection to the Power Grid. Any and all of the energy generated by solar energy systems may be transferred directly into the utility grid. Any connections shall comply with all other applicable City ordinances and policies and all applicable State or Federal laws.
(Ord. No. 2019-70, § 1, 11-12-19; Ord. No. 2025-07, § 3, 3-25-25)