§ 7-414 — Means of egress

Code of Ordinances of the City of Huntsville, Alabama (Supp. No. 30 (codified through Ord. No. 26-196, adopted March 12, 2026) with enacted ordinances through Ord. No. 26-837 (September 24, 2026) applied from official council minutes and ordinance copies) · Huntsville Code of Ordinances § 7-414

Corpus is an independent public-information project, not the official City of Huntsville website. Stable reference: corpuslaw.us/code/6c7cfe5d-990a-4f21-9477-25a38809cba9

Sec. 7-414. - Means of egress.

Every dwelling unit shall have safe, unobstructed means of egress with minimum ceiling height of seven feet leading to safe and open space at ground level. Stairs shall have a minimum headroom of six feet eight inches. In a multi-family building or structure a safe, continuous and unobstructed path of travel to a safe and open space or public way shall be provided. All means of egress doors shall be readily openable from the side from which egress is made without the use of keys or tools, and shall be equipped with the proper hardware.

(Ord. No. 90-174, § 305.4, 4-26-1990; Ord. No. 04-947, 12-9-2004)