§ 23-6-3(E) — Perimeter Buffers
Code of Ordinances, City of Biloxi, Mississippi (Supp. No. 63, Update 1: codified through Ordinance No. 2607, enacted July 28, 2026) · Biloxi Land Development Ordinance § 23-6-3(E)
Corpus is an independent public-information project, not the official City of Biloxi website. Stable reference: corpuslaw.us/code/6c940e56-ff17-4202-947a-c33fc1166494
(E) - Perimeter Buffers
(1) Purpose and Intent Perimeter landscape buffers are intended to mitigate potential negative effects of contiguous uses in different zoning districts. (2) Applicability Except for single-family detached dwellings and uses in the Downtown (DT) district, all development shall provide a perimeter landscape buffer to separate it from a different existing use on abutting land, or from vacant abutting land in a different zoning district, in accordance with Table 23-6-3(E)(3), Buffer Types, and Table 23-6-3(E)(4), Buffer Type Application. (3) Types of Buffers Table 23-6-3(E)(3), Buffer Types, describes four different types of perimeter buffer in terms of their function, opacity, width, and planting requirements. Where a particular buffer type is required in Table 26-6-3(E)(4), Buffer Type Application, the requirement may be met with the combination of minimum buffer width and minimum screening requirements specified under either Option 1 or Option 2. The option used shall be designated on the site plan for the development. Where an option utilizing a berm or fence is selected, the berm or fence shall comply with the standards of Section 23-6-3(C)(6), Berms, or Section 23-6-7, Fences and Walls, as appropriate. TABLE 23-6-3(E)(3): BUFFER TYPES ACI = AGGREGATE CALIPER INCHES co;normal;normal BUFFER TYPE AND CONFIGURATIONco;normal;normal | MINIMUM SCREENING REQUIREMENTS WITHIN PERIMETER BUFFER 1,2,3,4 co;normal;normal OPTION 1: MINIMUM WIDTH 20 FEETco;normal;normal | OPTION 2: MINIMUM WIDTH 10 FEET 5 co;normal;normal TYPE A - BASIC This perimeter buffer functions as basic edge demarcating individual properties with a slight visual obstruction from the ground to a height of ten feet. | 2 ACI of canopy trees + 10 ACI of understory trees + 15 shrubs per 100 linear feet TYPE B - AESTHETIC This perimeter buffer functions as an intermittent visual obstruction from the ground to a height of at least 20 feet, and creates the impression of spatial separation without eliminating visual contact between uses. | 8 ACI of canopy trees + 10 ACI of understory trees + 15 shrubs per 100 linear feet | 2 ACI of canopy trees +14 ACI understory trees + 35 shrubs per 100 linear feet TYPE C - SEMI-OPAQUE This perimeter buffer functions as a semi-opaque screen from the ground to at least a height of six feet. | 12 ACI of canopy trees + 14 ACI of understory trees + 25 shrubs per 100 linear feet | One 4-foot-high berm or one 4-foot-high solid fence + 2 ACI of canopy trees + 16 ACI understory trees per 100 linear feet TYPE D - OPAQUE This perimeter buffer functions as an opaque screen from the ground to a height of at least six feet. This type of buffer prevents visual contact between uses and creates a strong impression of total separation. | 18 ACI of canopy trees + 20 ACI of understory trees + 55 shrubs per 100 linear feet | One 6-foot-high solid fence + 12 ACI of canopy trees per 100 linear feet NOTES: 1. Any required perimeter buffer width can be reduced to five feet with the provision of a solid masonry wall at least five feet in height, along with ten large shrubs per every 100 linear feet. 2. Perimeter buffer widths (but not vegetation amounts) may be reduced in accordance with Section 23-2-4(Q), Administrative Adjustment. 3. Where an adjacent use is designed for solar access, understory trees can be substituted for canopy trees. 4. Berms shall comply with the standards in Section 23-6-3(C)(6), Berms, and fences and walls shall comply with the standards in Section 23-6-7, Fences and Walls. [image omitted; see the official code] Table 23-6-3(E)(3): Buffer Types (4) Buffer Type Application Table 23-6-3(E)(4), Buffer Type Application, specifies the type of perimeter landscape buffer that new development shall provide between it and adjacent property, based on the proposed use type on the development site and the existing use type on the abutting property or the zoning district in which abutting vacant property is located. The buffer type is indicated by a letter corresponding to one of the four buffer types depicted in Table 23-6-3(E)(3), Buffer Types. TABLE 23-6-3(E)(4): BUFFER TYPE APPLICATION 1 A = TYPE A BUFFER B = TYPE B BUFFER C = TYPE C BUFFER D = TYPE D BUFFER n/a = NOT APPLICABLE (no buffer required) co;normal;normal EXISTING USE TYPE ON ABUTTING LAND co;normal;normal | ZONING OF ABUTTING VACANT LAND co;normal;normal | PROPOSED USE TYPE 2,3 co;normal;normal SINGLE-FAMILY DETACHED RESIDENTIAL co;normal;normal | ALL OTHER RESIDENTIAL co;normal;normal | MIXED-USE & PUBLIC AND INSTITUTIONAL co;normal;normal | COMMERCIAL co;normal;normal | INDUSTRIAL co;normal;normal Single-Family Detached Dwelling | A, RE, RER, RS-10, RS-7.5, RS-5 | n/a | A | B | C | D All Other Residential 4 | RM-10, RM-20, RM-30, RMH | n/a | n/a | A | B | D Mixed-Use & Public and Institutional | LB, NB | n/a | n/a | n/a | A | D Commercial | CB, RB, DT, WF | n/a | n/a | n/a | n/a | C Industrial | I | n/a | n/a | n/a | n/a | n/a NOTES: 1. Letters in cells correspond to the buffer types depicted in Table 23-6-3(E)(3), Buffer Types. 2. Development in PD Districts is subject to perimeter buffer requirements in the PD District standards. Where development is proposed next to an existing PD District having no perimeter buffer, the proposed development shall provide a perimeter buffer that is consistent with the type of buffer required for an abutting use comparable to the use type of the PD District as a whole. 3. Multifamily, single-family attached or townhouse, multi-building campus, or shopping center developments shall provide buffers around the perimeter of the development instead of around individual buildings. 4. Manufactured home parks shall provide a perimeter buffer around the park in accordance with the standards in Section 23-4-3(B)(1)i., Manufactured Home Park. (5) Development Abutting Existing Buffer Where a developing parcel abuts an existing use and application of a perimeter buffer is required by Table 23-6-3(E)(4), Buffer Type Application, the developing parcel shall provide the entire minimum perimeter buffer width and screening required by Table 23-6-3(E)(3), Buffer Types, unless a portion or all of a perimeter buffer that complies with the standards of this section already exists between the parcels. Where such an existing buffer does not fully comply with the width and screening standards for the required buffer type, the developing parcel shall be responsible for providing all the additional buffer width and planting material necessary to meet the standards of this section. (6) Location of Buffers Perimeter buffers required by this section shall be located along the outer perimeter of the parcel and shall extend to the parcel boundary line or right-of-way line; however, the perimeter buffer may be located along shared access easements between parcels in nonresidential developments. (7) Development within Required Buffers a. The required buffer shall not contain any development, impervious surfaces, or site features (except fences or walls) that do not function to meet the standards of this section or that require removal of existing vegetation, unless otherwise permitted in this Ordinance. b. Sidewalks, trails, and other elements associated with passive recreation may be placed in perimeter buffers if all required landscaping is provided and damage to existing vegetation is minimized to the maximum extent practicable. c. Overhead and underground utilities required or allowed by the city are permitted in buffers, but shall minimize the impact to vegetation, to the maximum extent practicable. Where required landscaping material is damaged or removed due to utility activity within a required buffer, the landowner shall be responsible for replanting all damaged or removed vegetation as necessary to ensure the buffer meets the standards in this Ordinance. (8) Sight Triangles No fencing, berms, walls, or other landscaping features may exceed a height of three feet above grade within required sight triangles for streets, alleys, or driveways. (9) Credit for Existing Vegetation Existing vegetation located within the perimeter buffer area that meets the size standards of Section 23-6-3(C)(3), New Planting Standards, may be preserved and credited toward the perimeter buffer standards. (10) Credit for Required Landscaping Required landscaping associated with perimeter landscaping around a vehicular use area or stormwater pond, or with required screening located within ten feet of the perimeter buffer, may be credited towards the perimeter buffer requirements of this subsection.
Ask a question about Biloxi law
Corpus searches the Biloxi sections it holds and shows the ones that match, with their citations. Free, no sign-in.
