New construction and substantial improvements.
Richmond, Va., City Code § 14-88
in effectSec. 14-88. - New construction and substantial improvements.
(a) All substantial improvements to existing structures or new construction within any floodplain district shall conform to the applicable sections of the Virginia Uniform Statewide Building Code.
(b) New construction or substantial improvement of any existing commercial, industrial, or nonresidential building (or manufactured home) shall have the lowest floor, including basement, elevated to no lower than one foot above the base flood elevation. A registered professional engineer or architect shall certify that the standards of this subsection are satisfied.
(c) For historic structures as defined in this article, where elevation is not preferable, floodproofing may be allowed instead of elevation one foot above the base flood elevation. A registered professional engineer or architect shall certify on the certificate plans and floodproofing certificate that the construction design and methods meet the applicable requirements and shall submit such certificate to the Director.
(d) Fully enclosed areas below the lowest floor shall be used solely for parking of vehicles, building access or storage and shall have permanent openings designed to allow the entry and exit of floodwaters in accordance with specifications as set forth at 44 CFR 60.3(c)(5).
(Code 1993, § 13-67; Code 2004, § 50-97; Code 2015, § 14-88; Code 2020, § 14-88; Ord. No. 2009-12-31, § 1, 2-23-2009; Ord. No. 2014-95-66, § 3, 4-28-2014)
Source: City of Richmond, Virginia, Code (2026 recodification) and Charter (Municode Library, library.municode.com)URL: https://library.municode.com/va/richmond/codes/code_of_ordinances?nodeId=PTIICICO_CH14FLMAERSECODR_ARTIIFLMA_DIV3DIRE_S14-88NECOSUIMFetched: 11/8/2026