§ 18.50.180 — SPACE AND OCCUPANCY STANDARDS
City Code of Salt Lake City, Utah (2026 S-21: current through Ord. 49-26, passed September 15, 2026) · Salt Lake City Code § 18.50.180
Corpus is an independent public-information project, not the official City of Salt Lake City website. Stable reference: corpuslaw.us/code/6d724fb6-f605-4b3a-a9b1-228fa8bffee1
18.50.180: SPACE AND OCCUPANCY STANDARDS:
A. Ceiling Heights: 1. Habitable Rooms: The minimum ceiling height for all habitable rooms shall be as set forth in the construction codes adopted in Section 18.04.040. This height may be 6 feet 4 inches when the requirements of this chapter for emergency egress, light and ventilation are met and a smoke detector and carbon monoxide detector are installed pursuant to the construction codes adopted in Section 18.04.040. The only exception is that a smoke detector is not required in a kitchen. Obstructions shall be allowed to 5 feet 10 inches when the obstruction is not in the pattern of circulation and obstructions are not greater than 20% of the floor area of the room. 2. Nonhabitable Rooms Except Bathrooms: All nonhabitable rooms, except bathrooms, shall have no minimum ceiling height requirement. 3. Bathrooms and Toilet Rooms: Bathrooms and toilet rooms shall have a minimum ceiling height of 6 feet 0 inches. Obstructions shall be allowed to 5 feet 10 inches. The bathroom ceiling height at the back of a sink, toilet or tub without shower may be sloped to a minimum height of 5 feet 0 inches at the wall when the ceiling height is no less than 6 feet 0 inches at a point 2 feet 0 inches from the wall adjacent to the bathroom plumbing fixture. 4. Sloping Ceilings: In any room with a sloping ceiling, at least one-half (1/2) the floor area shall have a minimum ceiling height as required by this section. No portion of the room with a ceiling height below 5 feet 0 inches may be used in the floor area computation. 5. Corridors: A minimum ceiling height of 6 feet 4 inches shall be required in corridors so long as there are a smoke detector and carbon monoxide detector installed pursuant to the construction codes adopted in Section 18.04.040. Obstructions shall be allowed to 5 feet 10 inches when the obstruction is not in the pattern of circulation and obstructions are not greater than 20% of the floor area of the corridor. B. Room and Corridor Size: 1. Floor Area and Room Dimensions: Floor area and room dimensions shall be as set forth in the construction codes adopted in Section 18.04.040. 2. Sleeping Room Dimensions: Every room used for sleeping shall have floor area equal to the amounts required by the construction codes adopted pursuant to Section 18.04.040. Where more than 2 persons occupy a room used for sleeping, the required floor area shall be increased at the rate of 50 square feet for each occupant in excess of 2. 3. Corridors: The minimum width of corridors shall be 36 inches. In dwelling units constructed prior to 1983, a minimum corridor width of 28 inches shall be permitted. C. Special Dwellings: 1. Efficiency Dwelling Units: An efficiency dwelling unit shall: a. Have a living room floor area equal to the amounts required by the construction codes adopted pursuant to Section 18.04.040. An additional 100 square feet of floor area shall be provided for each occupant in excess of two; b. Have a closet; c. Have a kitchen sink and cooking and refrigeration facilities, each having a clear working space of at least 30 inches in front of the fixture or appliance; d. Have a bathroom containing a toilet, sink and bathtub or shower. 2. Congregate Housing: Except for Shared Housing as defined in Title 21A, individual units in congregate housing shall have at least one room with not less than 70 square feet of floor area per occupant. When individual rooms are less than 120 square feet, a separate common room shall be provided of at least 120 square feet for each 10 units, with a minimum of one common room per floor. When separate rooms are not provided with cooking facilities, the common room may be a common kitchen with a floor area as defined by the floor area computation. D. Cooking Facilities: 1. Cooking Facilities in Dwelling Units: Each dwelling unit shall have a kitchen that supplies: a. A range with stove top and oven, or in the alternative, a nonportable cooktop and oven. Hot plates, pans, and similar units shall not be considered as cooking facilities. All cooking appliances shall be maintained in good working condition. b. An approved sink, with a minimum dimension of 12 inches by 12 inches by 4 inches deep. c. A minimum of 4 square feet of counter space. d. A refrigerator. 2. Cooking Facilities for Individual Units in Congregate Housing: As long as such cooking facilities do not encroach into the required floor area, required cooking facilities may be supplied in individual units, provided all of the following items are supplied: a. A range with stove top and oven, or in the alternative, a nonportable cooktop and oven. Hot plates, pans, and similar units shall not be considered as cooking facilities and are not allowed. Portable cooking devices are not allowed in individual rooms; b. An approved sink, with a minimum dimension of 12 inches by 12 inches by 4 inches deep; c. A minimum of 4 square feet of counter space; d. A refrigerator. 3. Common Kitchens in Congregate Housing: When cooking facilities are not provided within individual units, congregate housing shall have a common kitchen area which shall contain the following minimum facilities: a sink for each 20 tenants or portion thereof, a range for each 20 tenants or portion thereof, and a refrigerator for each 10 tenants or portion thereof. The minimum kitchen area shall be 120 square feet based on the floor area computation for the first 10 occupants or portion thereof, and an additional 30 square feet for each additional 10 persons or portion thereof. (Ord. 91-24, 2024: Ord. 74-98 §§ 11-13, 1998: Ord. 68-96 § 1, 1996: Ord. 55-95 § 4 (Exh. A), 1995)
Ask a question about Salt Lake City law
Corpus searches the Salt Lake City sections it holds and shows the ones that match, with their citations. Free, no sign-in.
