For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 16.16.230 — Amendments to gas/mechanical sections of the 2024 International Residential Code for One- and Two-Family Dwellings

The Code of the Metropolitan Government of Nashville and Davidson County (Supp. No. 53: codified through Ordinance No. BL2025-1141, approved December 17, 2025) · Metropolitan Code of Nashville and Davidson County § 16.16.230

Corpus is an independent public-information project, not the official City of Metropolitan Government of Nashville and Davidson County website. Stable reference: corpuslaw.us/code/6dbe085d-dd48-40cb-beff-c76a9998f81d

16.16.230 - Amendments to gas/mechanical sections of the 2024 International Residential Code for One- and Two-Family Dwellings.

The following amendments, deletions or additions to the 2024 Edition of the International Residential Code for One- and Two-Family Dwellings are hereby adopted by reference as fully as though copied into said Dwelling Code and thereby made a part of the Dwelling Code. A. Chapter 12 of the 2024 Edition of the International Residential code for One- and Two-Family Dwellings is hereby amended by adding the following new Section M1203: SECTION M1203 AUTHORITY TO DISCONNECT UTILITIES IN EMERGENCIES M1203 Authority. The building official shall have the authority to order disconnected a fuel supply or appliance that does not conform to this code; the building official shall also have the authority to order disconnected a gas utility service, or energy supplies to a building, structure, premises or equipment in case of emergency when necessary to eliminate an immediate hazard to life or property. A notice shall be attached to the energy supply or appliances stating the reason for disconnection. Such notices shall not be removed, nor shall the system or appliance be reconnected until authorized by the building official. B. Section M1601.1.1 of the 2024 Edition of the International Residential Code for One- and Two-Family Dwellings is hereby amended by adding the following new Section M1601.1.1(9): M1601.1.1(9) All ductwork installed in non-conditioned and not completely conditioned areas such as, but not limited to, crawl, attic and floor/ceiling assemblies shall be insulated. C. Section M1601.3 of the 2024 Edition of the International Residential Code for One- and Two-Family Dwellings is hereby amended by adding the following new Section M1601.3(1): M1601.3(1) Duct Coverings and linings, including adhesives where used, shall have a flame spread index not higher than 25, and a smoke-developed index of not over 50 when tested in accordance with ASTM E84 or UL 723, using the specimen preparation and mounting procedures of ASTM E2231. The spray application of polyurethane foam to exterior ducts to insulate or seal the duct is prohibited. D. Section M1601.4.1: Exception 1 of the 2024 Edition of the International Residential Code for One- and Two-Family Dwellings are hereby amended by deleting Section M1601.4.1: Exception 1, and replacing with the following: Exception 1. Using the specimen preparation and mounting procedures of ASTM E2231. The spray application of polyurethane foam to exterior ducts to insulate or seal the duct is prohibited. E. Chapter 19 of the 2024 Edition of the International Residential code for One- and Two-Family Dwellings is hereby amended by adding the following new Section M1901.3: M1901.3 Prohibited Location. Cooking appliances designed, tested, listed, or labeled for use in commercial occupancies shall not be installed within dwelling units or within any area where domestic cooking operations occur. F. Section G2407.6.2 and Figure G2407.6.2 of the 2024 Edition of the International Residential Code for One- and Two-Family Dwellings are hereby amended by deleting Sections G2407.6.2 and Figure G2407.6.2. G. Section G2415.6 of the 2024 Edition of the International Residential Code for One- and Two-Family Dwellings is hereby amended by adding a new Section G2415.6.1: G2415.6.1 Buried building piping. Piping shall not be installed in such a way as to be in contact with the ground or fill under a building or building floor slab. When the administrative authority determines that it is not practical to avoid the installation of building piping that is buried or laid under a floor slab, the gas piping shall be encased in wrought iron, plastic schedule 40 pipe or steel pipe. The casing shall extend into a normally usable and accessible portion of the building. At the point where the casing terminates in the building, the space between the casing and the gas piping shall be tightly and permanently sealed with materials such as commercial casing seals, plastic, foams, cement, tars or asphalt materials. The casing shall extend at least 4 inches (102 mm) outside the building and be vented and installed in a way as to prohibit the entrance of water. The entire installation shall be such that the gas piping can be readily replaced without damage to the building. H. Section G2417.1.1 of the 2024 Edition of the International Residential Code for One- and Two-Family Dwellings is hereby amended by deleting Section G2417.1.1 and substituting the following: G2417.1.1 Inspections. On completion of the installation, alteration, repair or replacement of gas piping, and prior to the use thereof, the building official shall be notified that the gas piping is ready for inspection. G2417.1.1.1 Accessibility for inspection. Excavations required for the installation of underground piping shall be kept open until such time as the piping has been inspected and approved. If piping is covered or concealed before approval, it shall be exposed on the direction of the building official. G2417.1.1.2 Required inspections. The building Official shall make the following inspections and shall either approve that portion of the work as completed or shall notify the permit holder wherein the same fails to comply with this code. G2417.1.1.3 Rough fuel-gas piping inspection. This inspection shall be made after gas piping authorized by the permit has been installed and before such piping has been covered or concealed or a fixture or appliance has been attached thereto. This inspection shall include a determination that the gas piping size, material and installation meet the requirements of this chapter. It shall also include an air pressure test, at which time the gas piping shall stand a pressure of not less than 10 pounds per square inch gauge (68.9 kPa gauge) and shall hold this pressure for a length of time of not less than twenty (20) minutes, with no perceptible drop in pressure. The test shall be made using air pressure only and be verified in writing by the gas/mechanical contractor on forms authorized by the Department of Codes Administration witnessed and signed. Retest or additional certification, in special situations may be required by the Director of Codes Administration or by his/her duly authorized representative. Necessary apparatus for conducting test shall be furnished by the permit holder. G2417.1.1.4 Final inspection. This inspection shall be made after piping authorized by the permit has been installed and after all portions thereof which are to be covered or concealed are so concealed and after all fixtures, appliances and shutoff valves have been attached thereto. G2417.1.1.5 Other inspections. In cases where the work authorized by the permit consists of a minor installation of additional piping to piping already connected to a gas meter, the foregoing inspection may be waived at the discretion of the building official. The building official shall make such inspections as deemed advisable in order to assure that the work has been performed in accordance with the intent of this code. I. Section G2417.4.1 of the 2024 Edition of the International Residential Code for One- and Two-Family Dwellings is hereby amended by deleting Section G2417.4.1 and substituting the following: G2417.4.1 Air Pressure Test. This inspection shall include an air pressure test, at which time the gas piping shall stand a pressure of not less than ten (10) pounds, per square inch gauge pressure and shall hold this pressure for a length of time of not less than twenty (20) minutes, with no perceptible drop in pressure. The test shall be made using air pressure only and verified in writing by the gas/mechanical contractor on forms authorized by the Department of Codes Administration witnessed and signed. Retest or additional certification, in special situations may be required by the Director of Codes Administration or by his/her duly authorized representative. The necessary apparatus for conducting the test shall be furnished by the permit holder. J. Section G2417.4.2 of the 2024 Edition of the International Residential Code for One- and Two-Family Dwellings is hereby amended by deleting Section G2417.4.2 and substituting the following: G2416.4.2 Air Pressure Test 2 psi and greater. Gas piping 2 psi or higher pressure must stand a pressure of a least 20 psi, but never less than ten (10) times the maximum pressure to which the piping will be subjected in operation, for a period of not less than twenty (20) minutes without showing any drop in pressure. K. Section G2427.4.1 of the 2024 Edition of the International Residential Code for One- and Two-Family Dwellings is hereby amended by deleting Section G2427.4.1 and substituting the following: G2427.4.1 Plastic Piping. Where plastic piping is used to vent an appliance, the material shall be listed and labeled in accordance with UL 1738. L. Section G2427.4.1.1 of the 2024 Edition of the International Residential Code for One- and Two-Family Dwellings is hereby amended by deleting Section G2427.4.1.1 and substituting the following: G2427.4.1.1 Plastic Vent Joints. Plastic pipe venting materials listed and labeled in accordance with UL 1738 shall be installed in accordance with the vent manufacturer's instructions. Where primer is required, it shall be of contrasting color.

(Ord. BL2025-898 § 3, 2025; Ord. BL2020-458 § 3, 2020; Ord. BL2015-1145 § 15, 2015; Ord. BL2010-679 § 1, 2010; Ord. BL2007-1373 § 4, 2007; Ord. BL 2001-703 § 4, 2001; Ord. 98-1445 §§ 52—57, 1998; Ord. 96-562 §§ 29—33, 1996; Ord. 95-1487 §§ 54—58, 1995; Ord. 92-118 § 14, 1992; Ord. 90-1253 § 1 (part), 1990; prior code § 19-1-41.2)