21.1-0102. - Amendment to International Residential Code.
The International Residential Code as adopted in Section 21.1-0101 is hereby changed and amended as follows:
Section R101.1 is hereby amended to read as follows:
R101.1 Title. These provisions shall be known as the Residential Code for One- and Two-Family Dwellings of the City of Fargo, and shall be cited as such and will be referred to herein as "this code."
Section R103.1 is hereby amended to read as follows:
R103.1 Creation of agency. The Inspections Department of the city of Fargo is hereby created and the official in charge thereof shall be known as the building official. The function of the agency shall be the implementation, administration and enforcement of the provisions of this code.
Section R104.8 is hereby amended to read as follows:
R104.8. Liability. The building official, member of the board of appeals or employee charged with the enforcement of this code, while acting for the jurisdiction in good faith and without malice in the discharge of the duties required by this code or other pertinent law or ordinance, shall not thereby be personally liable, either civilly or criminally, and is hereby relieved from personal liability for any damage accruing to persons or property as a result of any act or by reason of an act or omission in the discharge of official duties. This code shall not be construed to relieve from or lessen the responsibility of any person owning, operating, or controlling any building or structure for any damages to persons or property caused by defects, nor shall the code enforcement agency or the city be held as assuming any such liability by reason of the inspection authorized by this code or any permits or certificates issued under this code.
Section R105.2 is hereby amended to read as follows:
R105.2 Work exempt from permit. * * * *
Building:
1. Other than storm shelters, one-story detached accessory structures, provided the floor area does not exceed 120 square feet.
2. Fences not over 8.5 feet high.
* * * *
7. Swimming pools that are less than 24 inches (610 mm) deep.
* * * *
10. Decks not exceeding 120 square feet in area, that are not more than 7 inches above grade at any point, are not attached to a dwelling and do not serve the exit door required by Section R318.4.
Section R108.3 is hereby amended to read as follows:
R108.3 Building permit valuations. Building permit valuation shall include total value of the work for which a permit is being issued, such as electrical, gas, mechanical, plumbing equipment and other permanent systems, including materials and labor. If, in the opinion of the building official, the valuation is underestimated on the application, the permit shall be denied, unless the applicant can show detailed estimates to meet the approval of the building official. Final building permit valuation shall be set by the building official.
Section R201.3 is hereby amended to read as follows:
R201.3 Terms defined in other codes. Where terms are not defined in this code such terms shall have the meanings ascribed in other code publications of the International Code Council. Wherever the term 'International Plumbing Code' or 'International Private Sewage Disposal Code' is used in the International Residential Code, it shall mean the North Dakota State Plumbing Code. Wherever the term 'ICC Electrical Code' is used in the International Residential Code, it shall mean the National Electrical Code together with the North Dakota State Wiring Standards. Wherever reference is made to flood plain requirements, it shall mean the Fargo Flood Plain Management Ordinance together with the Fargo Flood Proofing Code (Fargo Municipal Code Article 21-06).
Section R202 is hereby amended to add a new definition as follows:
LANDING. A constructed platform at the top or bottom of a staircase or between one flight of stairs and another. A landing may not consist of soil, gravel, or sand.
Table R301.2 is hereby amended to read as follows:
[image omitted; see the official code]
Section R301.2.4 is hereby deleted in its entirety.
Section R301.2.4.1 is hereby deleted in its entirety.
Table R302.1(1) Exterior Walls. The fourth column is hereby amended as follows:
0 feet
≥ 3 feet
< 2 feet
≥ 2 feet to < 3 feet
≥ 3 feet
< 3 feet
3 feet
5 feet
< 3 feet
3 feet
Section R302.5.1 is hereby amended to read as follows:
R302.5.1 Opening protection. Openings from a private garage directly into a room used for sleeping purposes shall not be permitted. Other openings between the garage and dwelling unit shall be equipped with solid wood doors not less than 1⅜ inches (35 mm) in thickness, solid or honeycomb-core steel doors not less than 1⅜ inches (35 mm) thick, or 20-minute fire rated doors.
Section R306 is hereby deleted in its entirety.
Section R307.2 Construction. Storm shelters shall be constructed in accordance with this code and ICC 500.
Section R309.1 Townhouse automatic sprinkler systems. Is hereby amended to read as follows:
R309.1 Townhouse automatic sprinkler systems. An automatic residential sprinkler system shall be installed in townhouses which are located on a private street or private fire department access road that is required to be greater than 150 feet in length as required by Section 503 of the International Fire Code.
Section R309.2 One- and two-family dwelling automatic sprinkler systems. Is hereby deleted in its entirety.
Section R318.3.2 is hereby amended to read as follows:
R318.3.2 Floor elevations at other exterior doors. Exterior doors other than the required egress door shall be provided with landings or floors not more than 8 inches below the top of the threshold.
Exception: An exterior landing or floor is not required at the exterior doorway where a stairway with a total rise of less than 30 inches (762 mm) is located on the exterior side of the door, provided that the door does not swing over the stairway.
Section R318.7.5.1 is hereby amended to read as follows:
R318.7.5.1 Risers. The riser height shall be not more than 8 inches.
* * * *
Section R318.7.5.2 is hereby amended to add the following exception:
Exception: Where a landing is not provided or required by Sections R318.3, R318.3.2, or R318.7.6, the top tread of a stair serving exterior doors other than the required exit door, and in-swinging doors opening into an attached garage, shall be permitted to exceed the smallest tread by more than 3/8 inch (9.5 mm). Such a tread shall be at least 18 inches (457 mm) measured in the direction of travel.
Section R318.7.5.2.1 is hereby amended to read as follows:
R318.7.5.2.1 Winder treads. Winder treads shall have a tread depth of not less than 9 inches measured between the vertical planes of the foremost projection of adjacent treads at the intersections with the walkline. * * * *
Section R318.7.6 exceptions are hereby amended to read as follows:
Exceptions:
1. The top landing of an interior stairway, including those in an enclosed garage, shall be permitted to be on the other side of a door located at the top of the stairway provided that the door does not swing over the stairs.
2. At an enclosed garage, the top landing at the stair shall be permitted to be not more than 8 inches below the top of the threshold.
3. At exterior doors, a top landing is not required for an exterior stairway with a total rise of less than 30 inches , provided that the door does not swing over the stairway.
Section R319.2.3 is hereby amended to add the following exception:
Exception: Below grade emergency escape and rescue windows shall have a maximum sill height of 48 inches.
Section R319.4.2 is hereby amended to read as follows:
R319.4.2 Ladder and steps. Area wells with a vertical depth greater than 44 inches (1118 mm) shall be equipped with an approved, permanently affixed ladder or steps, usable with the window in the fully open position or shall be equipped with a permanently attached platform at least 30 inches by 16 inches. The maximum distance between the top of the window well and a platform shall be 42 inches and shall not impede the operation of the window. The ladder or steps shall not be obstructed by the emergency escape and rescue opening where the window or door is in the open position. Ladders and steps required by this section shall not be required to comply with Section R318.7.
Section R319.4.2.1 is hereby amended to add the following exception:
Exception: Terraced window wells with a maximum of 24 inches per vertical rise and minimum of 12 inches per horizontal projection on each level shall also be allowed.
Section R321.1.1 is hereby amended to read as follows:
R321.1.1 Where required. Guards shall be provided for those portions of open-sided walking surfaces, including floors, stairs, ramps and landings that are located more than 30 inches (762 mm) measured vertically to the floor or grade below or to the bottom of any window well within 36 inches (914 mm) horizontally to the edge of the open side. Insect screening shall not be considered as a guard.
Section R327.1 is hereby amended to read as follows:
R327.1 Space required. Fixtures shall be spaced in accordance with the requirements of the North Dakota State Plumbing Code and Figure R327.1, except for the clearance in front of the water closets and bidets, which shall be at least 24 inches.
Section R328 is hereby deleted in its entirety.
Section R401.1 is hereby amended to read as follows:
R401.1 Application. The provisions of this chapter shall control the design and construction of the foundation and foundation spaces for buildings. In addition to the provisions of this chapter, the design and construction of foundations in flood hazard areas and established by Table R301.2 shall meet the provisions of the Fargo Floodproofing Code (Article 21-06) and any other applicable requirements of the city of Fargo. Wood foundations shall be designed and installed in accordance with AWC PWF.
Section R401.3 exception is hereby deleted in its entirety.
Section R403.1.4.1 exceptions are hereby amended to read as follows:
Exceptions:
1. Protection of free-standing accessory structures of light-frame construction shall not be required.
2. Protection of free-standing accessory structures with an area of 400 square feet (37 m 2 ) or less, of other than light-frame construction shall not be required.
3. Uncovered decks need not be provided with footings that extend below the front line.
Section R404.1.3.2 is hereby amended to read as follows:
Section R404.1.3.2 Reinforcement for foundation walls. Concrete foundation walls shall be laterally supported at the top and bottom. Horizontal reinforcement shall be provided in accordance with Table R404.1.3.2(1). Vertical reinforcement shall be provided in accordance with Table R404.1.3.2(2), R404.1.3.2(3), R404.1.3.2(4), R404.1.3.2(5), R404.1.3.2(6), R404.1.3.2(7), R404.1.3.2(8), or Table R404.1.2(10) and Figure R404.1.2(1) or Table R404.1.2(11) and R404.1.2 (2). Vertical reinforcement for flat basement walls retaining 4 feet (1219 mm) or more of unbalanced backfill is permitted to be determined in accordance with Table R404.1.3.2(9). For basement walls supporting above-grade concrete walls, vertical reinforcement shall be the greater of that required by Tables R404.1.3.2(2) through R404.1.3.2(8) or by Section R608.6 for the above-grade wall. In buildings assigned to Seismic Design Category D0, D1 or D2, concrete foundation walls shall also comply with Section R404.1.4.2.
Table R404.1.3.2(10) is hereby enacted to read as follows:
Table R404.1.3.2(10)
Foundation Wall Reinforcing
Active Pressure = 45pd
Minimum Reinforcement for Concrete Foundation Walls
Wall Height (h) feet | Wall Thickness (t) inches | Vertical Reinforcing
8 | 8 | #4 @ 24" o.c. #5 (ii), 40" o.c.
10 | #4 @ 30" o.c. #5 Cii2 50" o.c.
9 | 8 | #4 @ 18" o.c. #5 (ii), 28" o.c.
10 | #4 @ 24" o.c. #5 (ii), 36" o.c.
10 | 10 | #4 @ 16" o.c. #5 (ii) 26" o.c.
Notes:
1. Chart is based on an active soil pressure of 45 pounds per cubic foot (pct).
2. Reinforcing steel shall be ASTM A615 Fy - 60,000 pounds per square inch (psi).
3. The vertical reinforcing bars are to be located on the inside face.
4. Minimum concrete strength Fc 1 = 3,000 pounds per square inch (psi).
5. Backfill shall not be placed until first floor framing and sheathing is installed and fastened or adequately braced and the concrete floor slab is in place, or the wall is adequately braced.
Table R404.1.3.2(11) is hereby enacted to read as follows:
Table R404.1.3.2(11)
Foundation Wall Reinforcing
Active Pressure = 65 pcf
Minimum Reinforcement for Concrete Foundation Walls
Wall Height (h) Feet | Wall Thickness (t) inches | Vertical Reinforcin
8 | 8 | #4 @ 18" o.c. #5 @ 26" o.c. #6 (ti), 40" o.c.
10 | #4 @ 24" o.c. #5 @ 36" o.c. #6 (ti), 52" o.c.
9 | 8 | #4@ 12" o.c. #5 @ 18" o.c. #6 (ti), 26" o.c.
10 | #4 @ 16" o.c. #5 @ 24" o.c. #6 (ti), 36" o.c.
10 | 10 | #4@ 12" o.c. #5 @ 18" o.c. #6 Cii2 24" o.c.
Notes:
1. Chart is based on an active soil pressure of 65 pounds per cubic foot (pct).
2. Reinforcing steel shall be ASTM A615 Fy - 60,000 pounds per square inch (psi).
3. The vertical reinforcing bars are to be located on the inside face.
4. Minimum concrete strength Fc 1 = 3,000 pounds per square inch (psi).
5. Backfill shall not be placed until first floor framing and sheathing is installed and fastened or adequately braced and the concrete floor slab is in place or the wall is adequately braced.
Figures R404.1.3.2(1) and R404.1.3.2(2) are hereby enacted as shown:
FIGURE R404.1.3.2(1)
[image omitted; see the official code]
FIGURE R404.1.3.2(2)
[image omitted; see the official code]
Section R507.3 is hereby deleted in its entirety.
Table R507.3.1 is hereby deleted in its entirety.
Section R602.7.2 is hereby amended to read as follows:
R602.7.2 Rim board headers. Rim board header size, material and span shall be in accordance with Table R602.7(1). Rim board headers shall be constructed in accordance with Figure R602.7.2 and shall be supported at each end by full-height studs. Rim board headers supporting concentrated loads shall be designed in accordance with accepted engineering practice.
Section R602.7.5 is hereby amended to read as follows:
R602.7.5 Supports for headers. Headers shall be supported on each end with one or more jack studs or with approved framing anchors in accordance with Table R602.7(1) or R602.7(2). The full-height stud adjacent to each end of the header shall be end nailed to each end of the header in accordance with Table R602.3(1).
Table R602.7.5 is hereby deleted in its entirety.
Table N1102.1.2 (R402.1.2) is hereby amended to read as follows:
TABLE N1102.1.2 (R402.1.2)
MAXIMUM ASSEMBLY U -FACTORS AND FENESTRATION REQUIREMENTS
Maximum Assembly U-Factors and Fenestration Requirements
Climate Zone | * * * * | 6 | * * * *
Vertical Fenestration U-Factor | * * * * | 0.32 | * * * *
* * * * | * * * * | * * * * | * * * *
Wood-Framed Wall U-Factor | * * * * | 0.057 | * * * *
* * * * | * * * * | * * * * | * * * *
Basement Wall U-Factor | * * * * | 0.059 | * * * *
* * * * | * * * *
(balance of table remains unchanged)
Table N1102.1.3 (R402.1.3) is hereby amended to read as follows:
TABLE N1102.1.3 (R402.1.3)
INSULATION MINIMUM R-VALUES AND FENESTRATION REQUIREMENTS BY COMPONENT
Insulation Minimum R-Values and Fenestration Requirements by Component
Climate Zone | * * * * | 6 | * * * *
Vertical Fenestration U-Factor | * * * * | 0.32 | * * * *
* * * * | * * * * | * * * * | * * * *
Wood-Framed Wall R-Value e, h | * * * * | 21 or 13 & 5 ci | * * * *
* * * * | * * * * | * * * * | * * * *
Basement Wall R-Value b, e | * * * * | 15 or 10 ci | * * * *
* * * * | * * * *
(balance of table remains unchanged)
Table N1102.5.1.1 (R402.5.2.2) is hereby amended to read as follows:
TABLE N1102.5.1.1 (R402.5.1.1)
AIR BARRIER, AIR SEALING AND INSULATION INSTALLATION
Air Barrier, Air Sealing and Insulation Installation
Component | Air Barrier Criteria | Insulation Installation Criteria
Basement, Crawl Space and Slab Foundations | * * * * | * * * * Exterior foundation insulation shall be covered and flashed to protect it from exposure to light and weather to a minimum of 6 inches (152 mm) below grade and be covered by a minimum 6-mil polyethylene slip sheet over the entire surface.
(balance of table remains unchanged)
Section N1104.2 is hereby deleted in its entirety.
Section N1104.3 is hereby deleted in its entirety.
Section N1103.6.3 (R403.6.3) is hereby deleted in its entirety.
Table N1106.5 (R406.5) is hereby amended to read as follows:
TABLE N1106.5 (R406.5)
MAXIMUM ENERGY RATING SYSTEM
Maximum Energy Rating Index
Climate Zone | Energy Rating Index Not Including OPP | Energy Rating Index Including OPP
* * * * | * * * * | * * * *
6 | 58 | 48
(balance of table remains unchanged)
Section M1502.4.2 is hereby amended to read as follows:
M1502.4.2 Duct installation. Exhaust ducts shall be supported at intervals not to exceed 4 feet and shall be secured in place. The insert end of the duct shall extend into the adjoining duct or fitting in the direction of airflow. Exhaust duct joints may be mechanically fastened. Ducts shall not be joined with screws. Where dryer exhaust ducts are enclosed in wall or ceiling cavities, such cavities shall allow the installation of the duct without deformation.
Section M1503.6 exception is hereby deleted in its entirety.
Section M1601.4.1 exceptions are hereby amended to read as follows:
Exceptions:
* * * *
3. For ducts having a static pressure classification of less than 2 inches of water column (500 Pa), additional closure systems shall not be required for continuously welded joints and seams and locking-type joints and seams.
Section M2005.1 is hereby amended to read as follows:
M2005.1 General. Water heaters shall be installed in accordance with the North Dakota State Plumbing Code, the manufacturer's instructions and the requirements of this code. * * * *
Section M2101.3 is hereby amended to read as follows:
M2101.3 Protection of potable water. The potable water system shall be protected from backflow in accordance with the provisions listed in the North Dakota State Plumbing Code.
Section M2101.10 is hereby amended to read as follows:
M2101.10 Tests. New hydronic piping systems shall be tested hydrostatically at a pressure of not less than 100 pounds per square inch (689 kPa). The duration of each test shall be not less than 15 minutes. Hydronic piping to be embedded in concrete shall be pressure tested and inspected prior to pouring concrete.
Section M2103.3 is hereby amended to read as follows:
M2103.3 Piping joints. * * * *
2. Copper tubing shall be joined by brazing complying with the North Dakota State Plumbing Code.
Figure G2407.6.1(1) [304.6.1(1)] is hereby deleted in its entirety.
Figure G2407.6.6(2) [304.6.1(2)] is hereby deleted in its entirety.
Section G2407.11 (304.11) is hereby amended to read as follows:
G2407.11 (304.11) Combustion air ducts. Combustion air ducts shall comply with all of the following:
* * * *
5. Ducts shall not terminate in an attic space.
Section G2413.6 (402.6) is hereby amended as follows:
G2413.6 (402.6) Allowable pressure drop. The design pressure loss in any piping system under maximum demand, from the point of delivery to the inlet connection of all appliances served, shall be such that the supply pressure at each appliance inlet is greater than or equal to the minimum pressure required by the appliance, but such pressure loss shall not be greater than .5 inch water column for gas pipe systems operating at less than 2 psi.
Section G2417.4.1 (406.4.1) is hereby amended to read as follows:
G2417.4.1 (406.4.1) Test pressure. The test pressure to be used shall be not less than 1 ½ times the proposed maximum working pressure, but not less than 25 psig (20 kPa gauge). Where the test pressure exceeds 125 psig (862 kPa gauge), the test pressure shall not exceed a value that produces a hoop stress in the piping greater than 50 percent of the specified minimum yield strength of the pipe.
Section G2425.12 (501.12) is hereby amended to read as follows:
G2425.12 (501.12) Residential and low-heat appliances flue lining systems. Flue lining systems for use with residential-type and low-heat appliances shall be limited to the following:
1. Clay flue lining complying with the requirements of ASTM C315 or equivalent when each appliance connected into the masonry chimney has a minimum input rating greater than 400,000 Btu/h. Clay flue lining shall be installed in accordance with Chapter 10.
2. Listed chimney lining systems complying with UL 1777.
3. Other approved materials that will resist, without cracking, softening or corrosion, flue gases and condensate at temperatures up to 1,800°F (982°C).
a. Aluminum (1100 or 3003 alloy or equivalent) not less than 0.032 inches thick up to 8 inches in diameter.
b. Stainless steel (304 or 430 alloy or equivalent) not less than 26 gauge (0.018 inches thick) to 8 inches in diameter or not less than 24 gauge (0.024 inches thick) 8 inches in diameter and larger.
c. When a metal liner other than a listed chimney liner is used, a condensation drip tee shall be installed and supported in an approved manner.
Section G2427.5.2 (503.5.3) is hereby amended to read as follows:
G2427.5.2 (503.5.3) Masonry chimneys. Masonry chimneys shall be built and installed in accordance with NFPA 211 and shall be lined in accordance with G2425.12.
Section G2439.7.2 (614.9.2) is hereby amended to read as follows:
G2439.7.2 (614.9.2) Duct installation. Exhaust ducts shall be supported at 4-foot (1219 mm) intervals and secured in place. The insert end of the duct shall extend into the adjoining duct or fitting in the direction of airflow. Ducts shall not be joined with screws. Where dryer exhaust ducts are enclosed in wall or ceiling cavities, such cavities shall allow the installation of the duct without deformation.
Section G2442.4 (618.4) is hereby amended to read as follows:
G2442.4 (618.4) Screen. Required outdoor air inlets shall be covered with a screen having ¼ -inch (6.4 mm) openings. Required outdoor air inlets serving a nonresidential portion of a building shall be covered with screen having openings larger than ¼ inch (6.4mm) and not larger than ½ inch.
Chapters 25 through 43 are hereby deleted in their entirety.
* * * *
APPENDIX BE - Radon Control Methods is hereby adopted in its entirety and incorporated herein by reference, subject to the following amendments:
BE101.1 General. This appendix contains requirements for new construction in jurisdictions where radon-resistant construction is required.
Figure BE101.1 and Table BE101.1 are hereby deleted in their entirety.
* * * *
BE103.1 General. The following construction techniques are intended to resist radon entry and prepare the building for post-construction radon mitigation, if necessary (see Figure BE103.1). These techniques are required in areas where designated by the jurisdiction. All potential entry routes, including but not limited to joints, penetrations, gaps, cracks, and openings, shall be cleared of debris and sealed.
* * * *
The Exception in BE103.2(2) Subfloor preparation is hereby deleted in its entirety.
* * * *
Section BE103.3 Soil-gas-retarder is hereby deleted in its entirety.
Section BE103.4 Entry routes is hereby deleted in its entirety.
Section BE103.4.1 Floor openings is hereby deleted in its entirety.
Section BE103.4.2 Concrete joints is hereby deleted in its entirety.
Section BE103.4.3 Condensate drains is hereby deleted in its entirety.
Section BE103.4.4 Sumps is hereby deleted in its entirety.
Section BE103.4.5 Foundation walls is hereby deleted in its entirety.
Section BE103.4.6 Dampproofing is hereby deleted in its entirety.
Section BE103.4.7 Air handling units is hereby deleted in its entirety.
Section BE103.4.8 Ducts is hereby deleted in its entirety.
Section BE103.4.9 Crawl space floors is hereby deleted in its entirety.
Section BE103.4.10 Crawl space access is hereby deleted in its entirety.
* * * *
Section BE104.1 Testing is hereby deleted in its entirety.
Source: 5348 (2022), 5390 (2023), 5493 (2025), 5514 (2025), 5533 (2025), 5550 (2026).