Sec. 4-801. - International Residential Code.
(a) Pursuant to the authority granted by Tennessee Code Annotated, Section 6-54-501 et. seq., the 2018 International Residential Code (for one and two family dwellings), together with all revisions associated therewith and forthcoming, including appendix G thereto, but excluding all other appendices thereto, and are hereby adopted by reference, effective January 1, 2021, with the following modifications: Section R101.1: Insert "City of Clarksville" Section R 101.2: Scope: Detached one- and two-family dwellings and multiple single family dwellings (townhouses) not more than three stories above grade plane in height with a separate means of egress and their accessory structures shall comply with the International Residential Code. Section (EB) R102.7: Delete "International Property Maintenance Code or the International Fire Code" and substitute "The City of Clarksville Property Maintenance Code." Section R113.4 Delete entirely and insert instead: R113.4 Violation penalties. Persons who shall violate a provision of this code or shall fail to comply with any of the requirements thereof or who shall erect, install, alter or repair mechanical work in violation of the approved construction documents or directive of the code official, or of a permit or certificate issued under the provisions of this code, shall be subject to a civil fine of FIFTY DOLLARS ($50.00), in addition to any other remedies or penalties provided by law or court order. Each day that a violation continues after due notice has been served regarding any violation shall be deemed a separate offense. Delete Section R301.2 (1): Insert the following words and figures in the chart: Subject To Damage From Ground Snow Load | Wind Speed (mph) | Seismic Design Category | Weathering | Frost Line depth: | Termite | Decay | Winter Design Temp: | Ice Shield Under-Layment Requirement | Flood Hazards | Air Freezing Index | Mean Annual Temp: 10 | 90 | C | Severe | 12" | Moderate to Heavy | Slight to Moderate | 14 deg. | No | 6-15-84 6-29-01 | 500 per 100 yrs. | 59 deg. TABLE R301.2(1) CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA Ground Snow Load | Wind Design | Seismic Design Category | Subject to Damage From | Winter Design Temp e | Ice Barrier Underlayment Required h | Flood Hazards g | Air Freezing Index i | Mean Annual Temp j Speed (mph) d | Topographic effects k | Special wind region l | Wind-borne debris zone m | Weathering a | Frost line depth b | Termite c 10 | 115 | NO | NO | NO | C | Severe | 12" | Moderate to Heavy | 14 | No | 6-15-84 6-29-01 | 514 | 59 deg. Manual J Design Criteria n Elevation | Latitude | Winter heating | Summer cooling | Altitude correction factor | Indoor design temperature | Design temperature cooling | Heating temperature difference 550' | 36 | 12 | 93 | 70 | 75 | Note P Cooling temperature difference | Wind velocity heating | Wind velocity cooling | Coincident wet bulb | Daily range | Winter humidity | Summer humidity Note P | Note P | Note P | 74 | M | Note P | Note P For SI: 1 pound per square foot = 0.0479 kPa, 1 mile per hour = 0.447 m/s a. Where weathering required a higher strength concrete or grade of masonry than necessary to satisfy the structural requirements of this code, the frost line depth strength required for weathering shall govern. The weathering column shall be filled in with the weathering index, "negligible," "moderate" or "severe" for concrete as determined from Figure R301.2(4). The grade of masonry units shall be determined from ASTM C34, C55, C62, C73, C90, C129, C145, C216 or C652. b. Where the frost line depth required deeper footings than indicated in Figure R403.1(1), the frost line depth strength required for weathering shall govern. The jurisdiction shall fill in the frost line depth column with the minimum depth of footing below finish grade. c. The jurisdiction shall fill in this part of the table to indicate the need for protection depending on whether there has been a history of local subterranean termite damage. d. The jurisdiction shall fill in this part of the table with the wind speed from the basic wind speed map (Figure R301.2(5)A). Wind exposure category shall be determined on a site-specific basis in accordance with Section R301.2.1.4. e. The outdoor design dry-bulb temperature shall be selected from the columns of 97½ percent values for winter from Appendix D of the International Plumbing Code. Deviations from the Appendix D temperatures shall be permitted to reflect local climates or local weather experience as determined by the building official. [Also see Figure R301.2(1).} f. The jurisdiction shall fill in this part of the table with the seismic design category determined from Section R301.2.2.1. g. The jurisdiction shall fill in this part of the table with (a) the date of the jurisdiction's entry into the National Flood Insurance Program (date of adoption of the first code or ordinance for management of flood hazard areas), (b) the date(s) of the Floor Insurance Study and (c) the panel numbers and dates of the currently effective FIRMs and FBFMs or other flood hazard map adopted by the authority having jurisdiction, as amended. h. In accordance with Sections R905.1.2, R905.4.3.1, R905.5.3.1, R905.6.3.1, R905.7.3.1, and R905.8.3.1, where there has been a history of local damage from the effects of ice damming, the jurisdiction shall fill in this part of the table with "YES." Otherwise, the jurisdiction shall indicate "NO" in this part of the table. i. The jurisdiction shall fill in this part of the table with the 100-year return period air freezing index (BF-days) from Figure R403.3(2) or from the 100-year (99 percent) value on the National Climate Data Center data table "Air Freezing Index-USA Method (Base 32°F)." j. The jurisdiction shall fill in this part of the table with the mean annual temperature from the National Climatic Data Center data table "Air Freezing Index-USA Method (Base 32°F)." k. In accordance with Section R301.2.1.5, where there is local historical data documenting structural damage to buildings due to topographic wind speed-up effects, the jurisdiction shall fill in this part of the table with "YES." Otherwise, the jurisdiction shall indicate "NO" in this part of the table. l. In accordance with Figure R301.2(5)A, where there is local historical data documenting unusual wind conditions, the jurisdiction shall fill in this part of the table with "YES" and identify any specific requirements. Otherwise, the jurisdiction shall indicate "NO" in this part of the table. m. In accordance with Section R301.2.1.2 the jurisdiction shall indicate the wind-borne debris wind zone(s). Otherwise, the jurisdiction shall indicate "NO" in this part of the table. n. The jurisdiction shall fill in these sections of the table to establish the design criteria using Table 1a or 1b from ACCA Manual J or established criteria determined by the jurisdiction. o. The jurisdiction shall fill in this section of the table using the Ground Snow Loads in Figure R301.2(6). p. This shall be determined using "Manual J Design Criteria." Delete Section R313 in its entirety: Automatic Fire Sprinkler Systems Delete Section R313.1: Automatic Sprinkler Systems in Townhouses. "An automatic residential fire sprinkler system shall not be required if a 2 hour fire resistance rated wall exists between units, if such walls do not contain plumbing and/or mechanical equipment, ducts, or vents in the common wall. Delete Section R313.2: Automatic Sprinkler systems in 1&2 Family Dwellings. This shall not apply to stacked duplexes and the automatic sprinkler requirements set forth in City Code Sec. 7-210. Delete entirely Chapter 11: Energy Conservation Section P2603.5.1: Insert "18 inches" Section 2904: Dwelling Unit Fire Sprinkler Systems: Delete entirely Amend Section 2905.4.2: Insert new Section 2906.4.1: Delete "Water-service piping is permitted to be located in the same trench with a building sewer provided such sewer is constructed of materials listed for underground use within a building in Section P3002.1(2), if the building sewer is not constructed of materials listed in Section P3002.1(2)." Section P3103.1 Insert "12 inches" Delete "or (number) inches above the anticipated snow accumulation," Delete entirely Chapters 34 through 43 (Electrical) (b) Three (3) copies of the code shall be filed in the office of the building official.
(Ord. No. 46-2005-06, 12-1-05; Ord. No. 99-2010-11, 7-7-11; Ord. No. 11-2011-12, 9-1-11; Ord. No. 13-2013-14, 10-3-13; Ord. No. 64-2016-17, § 16, 6-1-17; Ord. No. 40-2020-21, § 16, 12-3-20; Ord. No. 64-2025-26, 5-7-26)
Ask a question about Clarksville law
Corpus searches the Clarksville sections it holds and shows the ones that match, with their citations. Free, no sign-in.