§ 33.140.265 — Residential Development
Portland City Code (non-zoning titles; Title 33 separately); partial · Portland Zoning Code § 33.140.265
Corpus is an independent public-information project, not the official City of Portland website. Stable reference: corpuslaw.us/code/6ea78148-add0-4a47-a4a9-49c27cb90150
33.140.265 Residential Development
When allowed, residential development is subject to the following development standards: A. Generally. Except as specified in this section, base zone development standards continue to apply; B. Existing buildings. Residential uses in existing buildings have no density limit within the building; C. New development. Residential uses in new development are subject to the development standards of the EX zone, except as specified in this section; D. Residential main entrance. 1. Purpose. The main entrance standards serve several purposes: • The main entrance standards, together with the window and garage standards ensure that there is a physical and visual connection between the living area of the residence and the street; • They enhance public safety for residents and visitors and provide opportunities for community interaction; • They ensure that the pedestrian entrance is visible or clearly identifiable from the street by its orientation or articulation; and • They ensure that pedestrians can easily find the main entrance, and so establish how to enter the residence. • Ensure a connection to the public realm for development on lots fronting both private and public streets by making the pedestrian entrance visible or clearly identifiable from the public street. 2. Where these standards apply. a. The standards of this subsection apply to houses, attached houses, manufactured homes, duplexes, attached duplexes, triplexes, and fourplexes in the employment and industrial zones. b. Where a proposal is for an alteration or addition to existing development, the standards of this section apply only to the portion being altered or added. c. On sites with frontage on both a private street and a public street, the standards apply to the site frontage on the public street. On all other sites with more than one street frontage, the applicant may choose on which frontage to meet the standards. d. Development on flag lots or on lots which slope up or down from the street with an average slope of 20 percent or more are exempt from these standards. 3. Location. At least one main entrance for each structure must: a. Be within 8 feet of the longest street-facing wall of the structure; and b. Either: (1) Face the street. See Figure 140-7; (2) Be at an angle of up to 45 degrees from the street; or (3) Open onto a porch. See Figure 140-8. The porch must: • Be at least 25 square feet in area; • Have at least one entrance facing the street; and • Have a roof that is: − No more than 12 feet above the floor of the porch; and − At least 30 percent solid. This standard may be met by having 30 percent of the porch area covered with a solid roof, or by having the entire area covered with lattice or other open material if no more than 70 percent of the area of the material is open. 4. Duplexes on corner lots. Where a duplex is on a corner lot, the requirements of Paragraph C.3, above, must be met for both dwelling units. Both main entrances may face the same street. E. Street-facing facades. 1. Purpose. The standard: • Together with the main entrance and garage standards, ensures that there is a visual connection between the living area of the residence and the street; • Enhances public safety by allowing people to survey their neighborhood from inside their residences; and • Provides a more pleasant pedestrian environment by preventing large expanses of blank facades along streets. 2. Where this standard applies. The standard of this subsection applies to houses, attached houses, manufactured homes, duplexes, attached duplexes, triplexes, and fourplexes in the Employment and Industrial zones. Where a proposal is for an alteration or addition to existing development, the applicant may choose to apply the standard either to the portion being altered or added, or to the entire street-facing facade. Development on flag lots or on lots that slope up or down from the street with an average slope of 20 percent or more are exempt from this standard. 3. The standard. At least 15 percent of the area of each facade that faces a street lot line must be windows or main entrance doors. Windows used to meet this standard must allow views from the building to the street. Glass block does not meet this standard. Windows in garage doors do not count toward meeting this standard, but windows in garage walls do count toward meeting this standard. To count toward meeting this standard, a door must be at the main entrance and facing a street lot line. Figure 140-7 Main Entrance Facing the Street


Figure 140-8 Main Entrance Opening Onto a Porch


F. Garages. 1. Purpose. These standards: • Together with the window and main entrance standards, ensure that there is a physical and visual connection between the living area of the residence and the street; • Ensure that the location and amount of the living area of the residence, as seen from the street, is more prominent than the garage; • Prevent garages from obscuring the main entrance from the street and ensure that the main entrance for pedestrians, rather than automobiles, is the prominent entrance; • Provide for a more pleasant pedestrian environment by preventing garages and vehicle areas from dominating the views of the neighborhood from the sidewalk; and • Enhance public safety by preventing garages from blocking views of the street from inside the residence. 2. Where these standards apply. The requirements of Paragraphs F.3 and F.4, below, apply to houses, attached houses, manufactured homes, duplexes, attached duplexes, triplexes, and fourplexes. When a proposal is for an alteration or addition to existing development, the standards of this section apply only to the portion being altered or added. Development on flag lots or on lots which slope up or down from the street with an average slope of 20 percent or more are exempt from these standards. 3. Length of street-facing garage wall. The length of the garage wall facing the street may be up to 50 percent of the length of the street-facing building facade. See Figure 140- 9. For attached houses and attached duplexes, the standard applies to the combined length of the street-facing facades of the attached units. 4. Street lot line setbacks. a. Generally. A garage wall that faces a street may be no closer to the street lot line than the longest street-facing wall of the dwelling unit. See Figure 140-11. b. Exception. A street-facing garage wall may be up to 6 feet in front of the longest street-facing wall of the dwelling unit, if: (1) The street-facing garage wall is 40 percent or less of the length of the building facade; and (2) There is a porch at the main entrance. The garage wall may not be closer to the street lot line than the front of the porch. See Figure 140-12. The porch must meet the following: • The porch must be at least 48 square feet in area and have minimum dimensions of 6 feet by 6 feet; • The porch must have a solid roof; and • The roof may not be more than 12 feet above the floor of the porch. c. Exemption. Where a lot has more than one street lot line, and there is an existing dwelling unit on the lot, this standard must be met only on the street-facing facade on which the main entrance is located.
Ask a question about Portland law
Corpus searches the Portland sections it holds and shows the ones that match, with their citations. Free, no sign-in.