§ 14-554 — Standards for areas of shallow flooding (AO/AH zones)

Code of Ordinances, City of Corpus Christi, Texas (Supp. No. 44: codified through Ordinance No. 033940, enacted June 2, 2026) · Corpus Christi Code of Ordinances § 14-554

Corpus is an independent public-information project, not the official City of Corpus Christi website. Stable reference: corpuslaw.us/code/6f1abc3f-3cc8-4230-9d19-1441f0643a46

Sec. 14-554. - Standards for areas of shallow flooding (AO/AH zones).

Locations within the areas of special flood hazard established in section 14-522 are designated as shallow flooding areas. These areas have special flood hazards associated with base flood depths of one (1) to three (3) feet, where a clearly defined channel does not exist and where the path of flooding is unpredictable and where velocity flow may be evident. Such flooding is characterized by ponding or sheet flow; therefore, the following provisions apply: (1) All new construction, of residential structures must have the lowest floor (including basement) and machinery or equipment elevated above the highest adjacent grade at least as high as the depth number specified in feet on the city's FIRM (at least two (2) feet if no depth number is specified) plus one (1) foot. Substantial damage and substantial improvement must have the lowest floor (including basement) and machinery or equipment, elevated above the highest adjacent grade at least as high as the depth number specified in feet on the city's FIRM (at least two (2) feet if no depth number is specified) plus one (1) foot. Attached garages and enclosures below elevated buildings must meet the minimum NFIP requirements (elevated to the base flood elevation or have proper openings). (2) All new construction of nonresidential structures: a. Must have the lowest floor (including basement) elevated above the highest adjacent grade at least as high as the depth number specified in feet on the city's FIRM (at least two (2)) feet plus one (1) foot, if no depth number is specified; or b. Substantial damage and substantial improvements must have the lowest floor (including basement) elevated above the highest adjacent grade at least as high as the depth number specified in feet on the city's FIRM (at least two (2)) feet, if no depth number is specified; or c. Together with attendant utility and sanitary facilities must be designed so that below the base flood level the structure is watertight with walls substantially impermeable to the passage of water and with structural components having the capability of resisting hydrostatic and hydrodynamic loads of effects of buoyancy. (3) A registered professional engineer or architect shall submit a certification to the floodplain administrator that the standards of this section, as proposed in subsection 14-533(b)(1), are satisfied. (4) Structures within zones AH or AO must have adequate drainage paths around structures on slopes, to guide floodwaters around and away from proposed structures.

(Ord. No. 25467, § 1, 9-9-2003; Ord. No. 031740, § 2, 4-16-2019; Ord. No. 032888, § 1, 10-11-2022)

Ask a question about Corpus Christi law

Corpus searches the Corpus Christi sections it holds and shows the ones that match, with their citations. Free, no sign-in.