IBC BUILDING CODE AMENDMENT, SECTION 1804.6, COMPACTED FILL MATERIAL
Boise City Code § 9-1A-58
in effect9-1A-58: IBC BUILDING CODE AMENDMENT, SECTION 1804.6, COMPACTED FILL MATERIAL:
1804.6 Compacted fill material. Where foundations will bear on compacted fill material, the compacted fill shall comply with the provisions of an approved geotechnical report, as set forth in Section 1803.
Exception: Compacted fill material 12 inches in depth or less need not comply with an approved report, provided the in-place dry density is not less than 95 percent of the maximum dry density at optimum moisture content determined in accordance with ASTM D 1557. The compaction shall be verified by special inspection in accordance with Section 1705.6.
(Ord. 44-17, 12-19-2017, eff. 1-1-2018; amd. Ord. 39-20, 12-1-2020, eff. 1-1-2021)
Source: Boise City, Idaho, City Code and City Charter (American Legal Publishing, codelibrary.amlegal.com)URL: https://codelibrary.amlegal.com/codes/boise_id/latest/boise/0-0-0-36936Fetched: 11/1/2026