Sec. 18-78. International Fuel Gas Code - Adopted and Amended.

(A) A certain document, one copy of which is on file in the City Clerk's Office of the City of Peoria, being marked and designated as "International Fuel Gas Code, 2018 Edition," published by the International Code Council is hereby adopted, as amended herein, as the Fuel Gas Code of the City of Peoria. (B) The International Fuel Gas Code, 2018 Edition, is amended as follows: (1) Chapter 1, "Scope and Administration" is hereby amended as follows: Note: For reserved sections herein, refer to the Building Code of the City of Peoria Administrative Provisions for these code requirements. 101.1 Title. Insert the words "City of Peoria" in the name of jurisdiction. Amend Section A101.3 Appendices to read as follows: [A] 101.3 Appendices. The following appendices are adopted: Appendix A - Sizing and Capacities of Gas Piping; Appendix B - sizing of Venting Systems Serving Appliances Equipped With Draft Hoods, Category 1 Appliances and Appliances Listed for Use With Type B Vents; Appendix C - Exit Terminals of Mechanical Draft and Direct-Vent Venting Systems. Delete Chapter 1, Part 2-Administration and Enforcement in its entirety and replace with the following: Part 2 - Administration and Enforcement Section 103 (IFGC) Department of Inspection. RESERVED. Section 104 (IFGC) Duties and Powers of the Code Official. RESERVED. Section 105 (IFGC) Approval. RESERVED. Section 106 (IFGC) Permits. RESERVED. Section 107 (IFGC) Inspections and Testing. RESERVED. Section 108 (IFGC) Violations. RESERVED. Section 109 (IFGC) Means of Appeal. RESERVED. Section 110 (IFGC) Temporary Equipment, Systems and Uses. RESERVED. (2) Chapter 4, "Gas Piping Installations" is hereby amended as follows: Amend Section 403 (IFGC) "Piping Materials" to read as follows: 403.12 Flanges. Flanges and flange gaskets shall comply with Sections 403.12.1 through 403.12.7. 403.12.1 Cast iron. Cast-iron flanges shall be in accordance with ASME 816.1. 403.12.2 Steel. Steel flanges shall be in accordance with ASME 816.5 or ASME 816.47. 403.12.3 Nonferrous. Nonferrous flanges shall be in accordance with ASME 816.24. 403.12.4 Ductile iron. Ductile-iron flanges shall be in accordance with ASME 816.42. 403.12.5 Raised face. Raised Face flanges shall not be joined to flat faced cast-iron, ductile-iron or nonferrous material flanges. 403.12.6 403.12.7 Lapped flanges. Lapped flanges shall be used only above ground or in exposed locations accessible for inspection. Amend SECTION 404 (IFGC) PIPING SYSTEM INSTALLATION to read as follows: Amend Section 404.12 Minimum burial depth to read as follows: 404.12 Minimum burial depth. "Underground metallic piping systems shall be installed a minimum depth of 12 inches (305 mm) below grade. Underground plastic piping systems shall be installed a minimum depth of 18 inches (457 mm) below grade." 404.12.1 Individual outside appliances. Delete in its entirety. (Ord. 07-32, 10/02/07, Enacted Sec 05-78 (SUPP 2007-4); Ord. 2012-08, 5/1/2012, Adopted 2012 Edition (SUPP 2012-2); Ord. No. 2017-31, § 27, 6-13-17; Ord. No. 2019-12, § 8, 5-21-19)

Ask a question about Peoria law

Corpus searches the Peoria sections it holds and shows the ones that match, with their citations. Free, no sign-in.