(B) - Sustainable Development Point Requirement

(1) All applications for approval of a Site Plan for nonresidential, mixed-use, and multifamily residential development shall incorporate a sufficient number of sustainable design options from Table 23-6-12(C), Sustainable Development Options and Points, to demonstrate achievement of the minimum number of points required below for the specific type of development. a. Nonresidential development and mixed-use development in the CB, RB, DT, and WF districts shall achieve at least 18 points. b. Nonresidential development and mixed-use development in all other districts shall achieve at least 12 points. c. Multifamily residential development shall achieve at least ten points. (2) Table 23-6-12(B), Sustainable Development Options and Points, sets forth a range of sustainable site and building design features and the number of points achieved by incorporating each design feature (or specified levels of the design feature). TABLE 23-6-12(B): SUSTAINABLE DEVELOPMENT OPTIONS AND POINTS co;normal;normal GREEN DESIGN FEATURE co;normal;normal | FEATURE DESCRIPTION co;normal;normal | POINTS co;normal;normal Efficient Cooling | All air conditioners are Energy Star qualified. | 2 Efficient Water Heating | At least 75 percent of hot water on premises is heated via tankless water heaters or solar water heaters. | 2 Gray Water Reuse | Water used for dish, shower, sink, and/or laundry purposes is reused for landscape or golf course irrigation. | 2 Green Building | The principal building meets or exceeds LEED certification for new construction. For sites with more than one principal building, points may be awarded for each. | LEED Bronze | 2 LEED Silver | 4 LEED Gold | 6 LEED Platinum | 8 Green Roof | At least 50 percent of the total surface area of the principal building's roof is a green roof. | 4 Herb or Vegetable Garden | At least one-fourth acre on the site consists of an edible herb or vegetable garden (which may be open to the public). | 2 Hurricane Resistant Structures | The principal building is constructed to meet increased wind loads. | 150 mph load minimum | 4 200 mph load minimum | 8 Infill or Mixed Use Development | The development constitutes infill development and/or mixed use development. | 4 Landscaped and Tree-Lined Street Median | Ingress and egress lanes of all non-service drives are separated by a landscaped median at least 5 feet wide and containing magnolia, pine, river birch, and/or oak trees that are spaced no more than 50 feet apart. | 2 Nature Trail | Public pedestrian and/or bicycle access to natural elements is provided by a trail that is at least one-fourth mile long per every 150,000 square feet of building floor area and does not intrude on or unduly harm existing natural features. | 1 Overhangs | Overhangs are present on all south windows for energy efficiency purposes. | 2 Permeable Parking Surfaces | Permeable surfacing materials are used for some or all of surface parking areas. | 25 percent minimum | 2 59 percent minimum | 4 Permeable Sidewalk Surfaces | Permeable or natural surfacing materials are used for all sidewalks. | 2 Permeable Trail Surfaces | Permeable or natural surfacing materials are used for all trails. | 1 Public Parking Facility | At least 75 percent of the development's total number of off-street parking spaces is contained in a public parking deck or garage. | 2 Public Parking Facility, Green | At least 50 percent of the total surface area of the top of the public parking facility is a green roof. | 4 Rain Gardens [Bioretention System] | The development includes rain gardens where each has an area of at least 100 square feet, is sized to hold stormwater runoff from between 5 and 10 percent of the impervious area draining to it, and consists of native plants planted in a sand/soil matrix soil bed with a mulch cover layer. | 1 rain garden | 1 2 rain gardens | 2 3 rain gardens | 3 4 or more rain gardens | 4 Rain Water Reuse | Rain water is captured and recycled for landscape or golf course irrigation. | 2 Skylights | The primary building is constructed with skylights that provide at least 10 percent of the light necessary for daily use on the story on which the skylights are located. | 1 Solar Panels | A portion of the energy used by the primary building is generated using solar panels located onsite. | 15 percent minimum | 4 30 percent minimum | 8 45 percent minimum | 12 Trawler Dock | The development includes an area, accessible through sufficiently deep water, for shrimp/oyster boats to dock and provide fresh, local seafood to casino/resort patrons. | 2 White Roof | All roof surfaces are painted white. | 2 Wind Turbines | A portion of the energy used by the primary building is generated using wind turbines located onsite. | 15 percent minimum | 4 30 percent minimum | 8 45 percent minimum | 12 Other | The development includes other green features that conserve energy, promote a healthy landscape, support public health and safety, or increase sustainability—points to be awarded at the discretion of the Director of Community Development. | Up to 6

Ask a question about Biloxi law

Corpus searches the Biloxi sections it holds and shows the ones that match, with their citations. Free, no sign-in.