Sec. 49-708. - Unisex restrooms.
The minimum fixture requirement for unisex restrooms shall be one water closet, one lavatory, and one urinal. (Exception: As noted in subsections (e) and (f). A restroom labeled "Men" or "Women" shall not serve as a unisex restroom).
(a) Unisex restrooms shall not be installed in the following facilities:
(1) Swimming pools.
(2) Schools (Exception: As noted in subsection (f)).
(3) Malls (Exception: As noted in subsection (d)).
(4) Where food or drinks are prepared or served.
Exception: Business not exceeding 750 gross square feet, with no customer seating (serving food and/or drink from a drive up window, offering carry-out or for delivery only) and four or fewer employees are normally stationed.
(b) A single unisex restroom is allowed where at least one of the following conditions applies:
(1) The gross area of the space occupied by a business where four or fewer employees are normally stationed is less than 2,000 gross square feet.
(2) Existing fixtures meet requirements for business occupancy, but the existing restrooms cannot be enlarged to meet disability accessibility requirements.
(3) Existing fixtures meet requirements for business occupancy and one or more additional unisex restroom(s) is desired for the convenience of the occupants.
(c) General requirements for unisex restrooms:
(1) Shall have a lockable door.
(2) Shall meet all disability accessibility requirements.
(3) The door or room shall be labeled accordingly:
(i) "Unisex Restroom" in letters minimum two inches in height, or other international symbol.
(ii) A sign indicating whether the room is occupied or unoccupied.
(d) Family or assisted use restrooms.
(1) Optional: Buildings in which all handicapped and non-handicapped fixture requirements for occupancy have been satisfied, optional additional unisex restroom(s) for family or assisted use may be installed.
(2) Required: In occupancies of assembly and mercantile where all handicapped and non-handicapped fixture requirements for occupancy have been satisfied and where a total of six or more water closets and urinals are required for occupancy, there shall be an additional separate restroom for family use. For each additional 20 required water closets and urinals thereafter, one additional family use restroom shall be provided. This requirement only applies to the required water closets and urinals.
(3) In new buildings requiring installation of family use restroom(s), the restroom shall be located adjacent to the restrooms required for occupancy.
The necessary floor to floor travel to the required family use restroom(s) shall not exceed one floor, up or down. (Exception: as may be required in section 49-722).
(4) In recreational facilities containing a shower or showers that are not located in single use bathing rooms, there shall be a separate bathing room for "Family or Assisted Use Only". The fixture requirements shall be one shower, one water closet and one lavatory.
(5) Family use restrooms shall meet all handicap accessibility requirements and shall meet all of the requirements set forth in subsections 49-708(a), (b), [and] (c) above, except that the door or room label shall bear the words "Family Use Restroom" in letters not less than two inches in height, or it shall be labeled with other international symbols.
(e) Medical office facilities:
(1) In medical offices in which all handicapped and non-handicapped fixture requirements for occupancy have been met, an additional restroom(s) may be installed to collect medical specimens.
(2) Where a restroom in a medical facility is used specifically for drug screening, the room may contain only a water closet. Installation of a lavatory and urinal will not be required.
(f) Schools, preschool and nursery:
(1) For preschool and nursery where children are five years old or under, a unisex restroom may be used. A unisex restroom for preschool or nursery children is not required to contain a urinal.
(2) For schools, a unisex restroom may be used in the nurse's office. The fixtures shall not be included to satisfy the fixture requirements for the occupancy.
(Ord. No. 40524, § 1, 10-20-15; Ord. No. 42654, § 21, 8-13-21)