§ 31-703.1 — Specific physical standards for residential condominium conversions

Salinas Municipal Code (Supp. No. 110, 9-26: codified through Ordinance No. 2696(NCS), passed June 16, 2026) · Salinas City Code § 31-703.1

Corpus is an independent public-information project, not the official City of Salinas website. Stable reference: corpuslaw.us/code/725fed5e-3bc3-4dad-be68-73311a99cfe7

Sec. 31-703.1. - Specific physical standards for residential condominium conversions.

(a) Building regulations. The project shall conform to the applicable currently adopted building codes and shall be found to be in compliance with the building regulations in Chapter 9 of this Code in effect on the date that the last building permit was issued for the subject structure or structures except as herein provided. Prior to final map or parcel map approval, the city shall receive a physical inspection report, by a qualified person(s), as determined by the building official, of every unit to verify compliance with this condition. (b) Health and safety—ground-fault circuit interrupters. In accordance with currently adopted building codes, ground-fault circuit interrupters shall be provided. (c) Fire prevention. (1) Smoke and carbon monoxide detectors. Each living unit shall be provided with the required number and location(s) of approved smoke and carbon monoxide detectors conforming to the latest California Building and Fire Code (as contained in Chapter 9 of this Code); (2) Maintenance of fire protection systems. All fire hydrants, fire alarm systems, portable fire extinguishers, exiting signs, panic hardware, and other fire protective appliances shall be retained in an operable condition at all times. (d) Sound transmission. (1) Shock mounting of mechanical equipment. All permanent mechanical equipment such as motors, compressors, pumps, and compactors which is determined by the building official to be a source of structural vibration or structure-borne noise shall be shock mounted with inertia blocks or bases and/or vibration isolators in a manner approved by the building official; (2) Noise standards. a. The structure shall conform to all interior sound-transmission standards of the California Building Code in a manner approved by the building official, b. The structure and site shall conform to all exterior noise standards prescribed by the general plan, c. In cases where present standards cannot reasonably be met by conditions of subdivision approval, the subdivider shall be required to notify potential buyers of the noise deficiency currently existing within these units. (e) Utility metering. Each dwelling unit shall be separately metered for gas, water, and electricity. A plan for equitable sharing of common area utility metering shall be developed prior to final map or parcel map approval and included in the covenants, conditions, and restrictions (CC&R's) prepared for the condominium conversion. (f) Private storage space. Each unit shall have at least two hundred cubic feet of enclosed, weather-proofed, and lockable private storage space in addition to guest, linen, pantry, and clothes closets customarily provided. Such space may be provided in any location approved by the city planner, but shall not be divided into two or more locations. In such cases where the subdivider can demonstrate that this standard cannot or should not reasonably be met, this standard may be modified by the city council or city planner upon approval of the tentative map or parcel map. (g) Laundry facilities. A laundry area shall be provided in each unit; or if common laundry areas are provided, such facilities shall consist of at least one automatic washer and one dryer of equivalent capacity for every five units of three or more bedrooms; for every seven two-bedroom units, and for every ten one-bedroom units. In such cases where the subdivider can demonstrate that this standard cannot or should not reasonably be met, this standard may be modified by the city council or city planner upon approval of the tentative map or parcel map. (h) Landscape maintenance. All landscaping shall be restored as necessary and maintained to achieve a high degree of appearance and quality. If a significant amount of new landscaping is required, the landscape plan shall be subject to the city planner's and city engineer's approval conforming to water conservation ordinance and water efficient landscape ordinance. (i) Condition of equipment and appliances. The subdivider shall provide a warranty to the buyer of each unit at the close of escrow that any dishwashers, garbage disposals, stoves, refrigerators, hot water tanks, and air conditioners that are provided have a useful life of one year. At such time as the homeowner's association takes over management of the development, the subdivider shall provide a warranty to the association that any pool and pool equipment (filter, pumps, and chlorinator) and any appliances and mechanical equipment to be owned in common by the association have a useful life of one year. Prior to final map or parcel map approval, the subdivider shall provide the city with a copy of warranty insurance covering equipment and appliances pursuant to this subsection. (j) Refurbishing and restoration. As a condition of the tentative map or parcel map approval, all main buildings, structures, fences, patio enclosures, carports, accessory buildings, sidewalks, driveways, landscaped areas, and additional elements, as required, shall be refurbished and restored as necessary to achieve a high level of design quality, appearance, and safety. These improvements shall occur prior to the approval of the final map. The subdivider shall provide to the homeowners' association and/or purchaser a one-year warranty on all physical improvements required under this section. If substantial restoration is required, the design plans shall be subject to the city planner's approval. (k) Conformance with the zoning code. As part of the review of the planned development permit required by Section 37.50-050, condominium conversions, the city shall determine conformance of the site and structures with the zoning code.

(Ord. No. 2585 (NCS), § 1, 12-13-2016)

Ask a question about Salinas law

Corpus searches the Salinas sections it holds and shows the ones that match, with their citations. Free, no sign-in.