§ 6-316 — Universal design and construction requirements
San Antonio City Code (Supp. No. 147: codified through Ordinance No. 2026-09-10-547, adopted Sept. 10, 2026) · San Antonio City Code § 6-316
Corpus is an independent public-information project, not the official City of San Antonio website. Stable reference: corpuslaw.us/code/74bca83a-38bc-4b32-9986-89e6094b1693
Sec. 6-316. - Universal design and construction requirements.
If a person receives financial assistance from city, state, or federal funds administered by the city for the construction of new single family homes, duplexes, or triplexes, that person shall construct the units in accordance with all other city codes and the following requirements. (1) At least one entrance shall have a 36-inch door and be on an accessible route. (An accessible route is a continuous, unobstructed path at least thirty-six (36) inches wide connecting all interior and exterior elements and spaces of a house and site including corridors, parking, curb ramps, crosswalks and sidewalks and served by a no-step, flat entrance with a beveled threshold of one-half-inch or less). (2) All interior door openings shall provide an unobstructed path no less than that provided by a 32-inches wide door, except for a door opening that provides access to a closet of fewer than fifteen (15) square feet in area. (3) Each hallway shall have a width of at least thirty-six (36) inches and shall be level or with ramped or beveled changes at each door threshold. (4) All bathrooms shall have the walls reinforced around the toilet for potential installation of grab bars. Walls around the shower and tub shall be reinforced for potential installation of grab bars or a pre-manufactured tub and shower surround may be used which includes grab bar(s) certified to meet the ADA requirement to bear a 250-pound load. Wall reinforcements shall comply with the standards set forth in requirement 6, Reinforced Walls For Grab Bars of the Fair Housing Act Design and Construction Guidelines; Federal Register/Volume 56 No.44/Wednesday, March 6,1991/Rules and Regulations, a copy of which is available for inspection at the office of the City Clerk. (5) Each electrical panel, light switch or thermostat shall be mounted no higher than forty-eight (48) inches above the floor. Each electrical plug or other receptacle shall be at least fifteen (15) inches from the floor. (6) An electrical panel located outside the dwelling unit must be between eighteen (18) inches and forty-two (42) inches above the finished grade and served by an accessible route. (7) All hardware installed to open/close doors and operate plumbing fixtures shall be lever handles.
(Ord. No. 95641, § 1, 4-18-02)
Ask a question about San Antonio law
Corpus searches the San Antonio sections it holds and shows the ones that match, with their citations. Free, no sign-in.
