For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 25.06.100 — General standards in A Zones including Zones A, AE, and AO

Seattle Municipal Code (Supp. No. 44: codified through Ordinance No. 127459, passed June 30, 2026) · Seattle Mun. Code § 25.06.100

Corpus is an independent public-information project, not the official City of Seattle website. Stable reference: corpuslaw.us/code/751ae187-b141-4cac-a809-66b82415773b

25.06.100 - General standards in A Zones including Zones A, AE, and AO

The following standards are required in all A zoned areas: A. Accessory structures (detached garages and small storage structures) 1. Accessory structures limited to 500 square feet and used solely for parking of vehicles or limited storage may be constructed such that the floor is below the flood protection elevation, provided the structure is designed and constructed in accordance with the following requirements: a. Use of the accessory structure must be limited to parking of vehicles or limited storage; b. The portions of the accessory structure located below the BFE must be built using flood resistant materials; c. The accessory structure must be adequately anchored to prevent flotation, collapse, and lateral movement. Accessory structures designed to float (e.g., boat sheds, covered moorage, and floating piers with structures on top) shall be securely anchored to an adequately anchored foundation system that resists flotation, collapse, and lateral movement; d. The accessory structure must comply with floodway encroachment provisions in subsection 25.06.120.A; e. The accessory structure must be designed to allow for the automatic entry and exit of floodwaters in accordance with subsection 25.06.110.A.3.b; f. The structure shall have low damage potential; g. If the structure is converted to another use, it must be brought into full compliance with the standards governing such use; and h. The structure shall not be used for human habitation. 2. Detached garages, storage structures, and other accessory structures not meeting the above standards must be constructed in accordance with all applicable standards in subsections 25.06.110.A and 25.06.110.B and Section 25.06.130. B. Anchoring 1. All new construction, substantial improvements, and manufactured homes shall be anchored to prevent flotation, collapse, or lateral movement of the structure resulting from hydrodynamic and hydrostatic loads including the effects of buoyancy. Anchoring methods may include, but are not limited to, use of over-the-top or frame ties to ground anchors. 2. All new construction and substantial improvement of structures designed to float as part of their function (e.g., boat sheds, covered moorage, and floating piers with structures on top) shall be securely attached to an adequately anchored foundation system that resists flotation, collapse, and lateral movement. C. Construction materials and methods 1. All new construction and substantial improvements shall be constructed with materials and attendant utilities and equipment resistant to flood damage. 2. All new construction and substantial improvements shall be constructed using methods and practices that minimize flood damage. 3. Electrical, heating, ventilation, plumbing, air-conditioning equipment, and other service facilities shall be designed and/or otherwise elevated or located, to prevent water from entering or accumulating within the components during conditions of flooding. D. Processing and storage of materials and equipment 1. Processing. As part of new construction and substantial improvements, the processing of hazardous materials and the process of using one or more operations that transforms a material into hazardous material is prohibited in special flood hazard areas. 2. Storage of materials and equipment a. Structures that store materials and equipment shall adhere to applicable flood code requirements for substantial improvement, new construction or accessory structures. b. The storage of materials or equipment outside a structure is prohibited in special flood hazard areas unless stored in a manner that is reasonably safe from flooding. E. Attendant utilities and equipment 1. All new and replacement water supply systems shall be designed to eliminate or minimize infiltration of floodwaters into the system. 2. Water wells shall be located on high ground outside the floodway. 3. New and replacement sanitary sewage systems shall be designed to eliminate or minimize infiltration of floodwaters into the systems and discharge from the systems into floodwaters. 4. On-site waste disposal systems shall be located to avoid impairment to them or contamination from them during flooding. 5. New or replacement attendant utilities and equipment shall be: a. Located at or above the flood protection elevation, or as required by ASCE 24, whichever is greater; or b. Designed and installed to prevent water from entering or accumulating within the components and to resist hydrostatic and hydrodynamic loads and stresses, including the effects of buoyancy, during the occurrence of flooding to the design flood elevation in accordance with ASCE 24; and c. Electrical wiring systems are permitted to be located below the flood protection elevation provided that they conform to the provisions of the electrical part of this code for wet locations and shall be anchored following the provisions of subsection 25.06.100.B. F. Subdivision, short plat, other platting actions, and other new development proposals: 1. Shall be consistent with the need to minimize flood damage. 2. Shall have public utilities and facilities, such as sewer, gas, electrical, and water systems, located and constructed to minimize flood damage. 3. Shall have adequate drainage to reduce exposure to flood damage. 4. Shall include base flood elevation data as part of the application for proposed development that contains at least 50 lots or 5 acres, whichever is less. G. Where elevation data is not available, whether from the FIS, the FIRM, or another authoritative source as listed in subsection 25.06.090.C, applications for floodplain development shall be reviewed to assure that proposed construction shall be made reasonably safe from flooding. The evaluation of reasonableness shall include consideration of historical data, high water marks, photographs of past flooding, and similar information if available.

(Ord. 127410, § 2, 2026; Ord. 126113, § 2, 2020; Ord. 125292, § 1, 2017 [amended effective date of Ord. 125248]; Ord. 125248, § 60, 2017 [cross-reference update]; Ord. 124447, § 6, 2014; Ord. 114395, § 1, 1989.)

Ask a question about Seattle law

Corpus searches the Seattle sections it holds and shows the ones that match, with their citations. Free, no sign-in.