Sec. 19-74. - Special requirements for manufactured homes.

Each manufactured home placed in, and any substantial improvement to a manufactured home site within a Houston special flood hazard area shall be secured as follows: (1) Anchors: Each manufactured home shall be elevated and anchored to resist flotation, collapse, or lateral movement in the presence of floodwaters by providing over-the-top or frame ties to ground anchors. Each ground anchor shall be set in concrete poured to a depth resistant to natural erosion caused by floodwater. In addition, each anchoring system shall comply with all applicable provisions of state law or regulations. Each component of the anchoring system for a manufactured home shall be capable of carrying a force of 4,800 pounds. (2) Tie-downs: a. Over-the-top ties shall be provided at each of the four corners of the manufactured home. b. A manufactured home in excess of 50 feet in length shall have two side ties in addition to the above-described corner ties, that shall be placed at intermediate locations; manufactured homes less than 50 feet in length shall have one additional tie per side. (3) Frame ties: a. A frame tie shall be placed at each corner of the manufactured home. b. A manufactured home in excess of 50 feet in length shall have five additional ties placed on each side at intermediate locations; manufactured homes less than 50 feet in length shall have four additional ties per side placed at intermediate locations. (4) Additions to manufactured homes: Each addition to a manufactured home shall be anchored in the same manner as a manufactured home. (5) Flood elevation of manufactured home: a. The stand or lot on which a manufactured home is placed shall be elevated on a permanent foundation so that the lowest floor of the manufactured home is at least at the minimum flood protection elevation. b. Adequate surface drainage and access for a hauler shall be provided at each manufactured home lot or stand and at the entrance of a manufactured home park or subdivision. c. A manufactured home placed on pilings shall be placed on a lot large enough to permit steps wholly on the manufactured home lot. d. Pilings shall be placed in stable soil not more than ten feet apart, center to center, and shall be reinforced if they extend more than six feet above ground level. A registered professional engineer licensed in the State of Texas must certify in writing that the size, strength, and treatment processes for wooden pilings and methods of reinforcement for those pilings are sufficient to prevent flotation, collapse or lateral movement of the manufactured home in the presence of floodwaters.

(Ord. No. 2018-258, § 2(Exh. A), 4-4-2018)

Ask a question about Houston law

Corpus searches the Houston sections it holds and shows the ones that match, with their citations. Free, no sign-in.