Sec. 4-312. - Manufactured homes.

1. Manufactured homes shall have listed, enclosed-type service entrance equipment located inside the manufactured home, with proper rated over-current protection for each branch circuit. Over-current protection for circuits of twenty (20) amperes or less may be either circuit breakers, or plug fuses and fuse holders of Type "S", and shall be of the time-delay type. The manufactured home disconnecting means located inside shall be fed from an outside location with a feeder from the main service entrance for such manufactured home. If the supply or feeder from the main service to the disconnecting means located inside does not have a grounding conductor as required by Article 550 of the 2008 National Electric Code, one will be installed. 2. Prior to the release of utility power connection, a State of Tennessee decal shall be adhered to the inside electrical panel, signifying that the manufactured home has been inspected by a state inspector.

(Ord. No. 12-2011-12, § 1, 9-1-11)