Pretreatment standards for existing sources (PSES).
40 C.F.R. § 415.654
in effectExcept as provided in 40 CFR 403.7 and 403.13, any existing source subject to this subpart which introduces pollutants into a publicly owned treatment works must comply with 40 CFR part 403 and achieve the following pretreatment standards for existing sources (PSES):
Subpart BM—Cobalt Salts
Pollutant or pollutant property
PSES effluent limitations
Maximum for any 1 day
Average of daily values for 30 consecutive days
Milligrams per liter (mg/l)
Cobalt (T)3.61.4
Copper (T)3.31.0
Nickel (T)3.31.0
In cases where POTWs find it necessary to impose mass limitations, the following equivalent mass limitations are provided as an alternate: The limitations for cobalt (T), copper (T), and nickel (T), are the same as specified in § 415.652.