A. Character and Image.
1. Entryway Monumentation Feature. Provide at least one (1) entryway monumentation feature at the primary entryway into a development. The primary entryway shall be the entrance accessing the street with the highest functional classification. Where multiple entrances access streets of the same highest functional classification, the Planning Director shall determine which entrance shall be the primary entryway for the purposes of this section. The entryway monumentation feature shall include at least three (3) of the following:
a. Monument signage.
b. Specialty pavement delineating the primary entryway, such as stamped asphalt, brick, stone, pavers, or colored concrete. Specialty pavement within the public right-of-way shall be approved by the City Transportation Department.
c. Enhanced perimeter wall details, such as but not limited to, decorative panels, lighting, architectural tower or arch feature, or a decorative gate.
d. Enhanced landscape treatment with a defined landscaped area of at least 200 square feet that includes a minimum of three (3) trees with a minimum 36-inch box size and decorative shrubs, perennials, ornamental grasses, or specimen plants. At least 60% of this landscaped area must contain live plant material.
e. Public art elements, such as but not limited to, a sculptural features or thematic elements that reflect neighborhood history, culture, or surrounding natural features.
f. Landscaped median or entry island.
g. Monument or gateway lighting features, such as but not limited to, uplighting, halo lighting, illuminated columns.
h. Neighborhood identity markers, such as but not limited to, branded poles, pylons, or similar vertical elements.
i. Decorative landscape wall or seat wall integrated with planting, in lieu of a perimeter wall.
j. Water feature.
k. Additional entryway monumentation feature approved by the Planning Director.
2. Architectural Variation. Where adjacent to existing multiple residence dwellings, unique massing and architectural design shall be provided to avoid the appearance of large contiguous developments.
B. Massing and Scale. Buildings shall contain varied massing and architectural elements and techniques shall be utilized to reduce the apparent massing and scale of buildings, provide shading, and define different uses and activities in the building.
1. Façade Articulation. Exterior building walls shall be subdivided and proportioned to human scale, using projections, overhangs and recesses in order to add architectural interest and variety and to avoid long, uninterrupted wall planes.
a. Publicly Visible Façades. All street-facing and publicly visible façades shall have at least one (1) horizontal projection or recess of at least four (4) feet in depth, or two (2) projections or recesses of at least 2.5 feet in depth, for every 25 horizontal feet of wall.
b. Two or More Story Buildings. If located on a building with two (2) or more stories, the articulated elements must be greater than one (1) story in height and may be grouped rather than evenly spaced in 25-foot modules so long as the total amount of articulation meets or exceeds that which would be required if no grouping occurred.
c. Building entrances, front porches, and projections such as stoops, bays, overhangs, fireplaces, and trellises count towards this requirement.
2. Varied Roof Form. Roof forms shall be integrated into the building design and varied within a development through the use of offsets; changes in slope, angle, or direction; and elements such as dormers, towers, or parapets.
3. Roof Articulation. Roof articulation is required to provide architectural interest at the skyline and accentuate appropriate building elements.
a. No more than two (2) side-by-side units may be covered by one (1) unarticulated roof.
b. Flat roofs in excess of 100 feet shall provide vertical modulation of two (2) or one-tenth ( 1/10 ) of the wall height, whichever is greater.
4. Balconies, Bay Windows, and Other Projections or Recesses. Buildings shall incorporate balconies, bay windows, entry porches or other projections and recesses across 30% of the length per floor of the façade.
a. Windows. Windows shall either:
i. Contain window trim on at least two (2) sides of all windows that is at least two (2) inches in depth; or
ii. Be recessed at least four (4) inches from the outside plane of the surrounding exterior wall.
b. Balconies. Balconies shall be at least four (4) feet wide and three (3) feet deep if not used to meet private open space requirements.
5. Façade Detailing and Materials. Each side of a building that is visible from a public right-of-way, private street, parking lot, or common open space shall be designed with a complementary level of detailing and quality of materials.
C. Materials. Buildings and structures shall be constructed of durable, high-quality materials appropriate for the Arizona climate
1. Primary Exterior Building Materials.
a. Primary exterior building materials are brick, stone, integrally tinted and textured masonry block, precast concrete, siding, synthetic wood, natural and synthetic stone, stucco and synthetic stucco, or other material approved by the Planning Director.
b. Variations in the color, finish, or texture of a material (e.g., form-board concrete, smooth stucco vs sand stucco, etc.) shall not be considered separate or distinct materials for the purpose of meeting the material requirements of this section.
c. Glazing may be considered as a primary exterior building material only when it is installed as an architectural glazing system (e.g., curtainwall, structural glass wall) and comprises more than 30% of an individual building façade. Standard window systems, storefront glazing, and other non-architectural fenestration shall not qualify as a primary exterior building material for the purposes of this requirement.
2. Minimum Use of Primary Materials.
a. Each building façade shall incorporate at least two (2) different primary exterior materials.
b. Primary exterior materials shall cover no less than 75% of each building façade.
c. Each primary building material used to satisfy Subsection (2)(a) above shall cover at least 25% of that façade.
d. Primary Material Calculation.
i. Primary building material coverage shall be calculated by measuring the area of each façade, excluding non-architectural fenestration, storefront systems, pedestrian and vehicular openings, mechanical equipment, and signage.
ii. The percentage of each primary building material shall be calculated by dividing the area covered by that material by the resulting façade area.
3. Architectural Metals. Architectural metals, such as bronze, brass, copper, aluminum, metal-composite material (MCM), and steel shall not cover more than 25% of a building façade.
4. Change in Materials.
a. Where material changes are horizontal (i.e., different materials side by side) the transition between materials shall occur at a change in wall plane, preferably at inside corners or where architectural elements intersect (e.g., pilasters, bays, projections), and shall not occur mid-field on a flat wall surface.
b. Where material changes are vertical (i.e., different materials stacked one above another), the transition between materials shall include a belt course, trim band, sill, cap, frame, or similar element to separate the two (2) materials.
D. Building Entrances. Primary building entrances shall be clearly defined, shaded, and inviting. The architectural details of building entrances shall be integrated with the overall building design in terms of materials, scale, proportion, and design elements and are appropriately scaled for people.
1. Dwelling Unit Access.
a. Ground Floor Access. Exterior entrances to units shall be in the form of individual or shared entrances at the ground floor of the building.
b. Upper Story Access. Individual entrances for units above the ground floor shall be provided via an interior corridor.
2. Orientation. All units located along public rights-of-way shall have the primary entrance to the building, or individual unit entrances, facing this right-of-way. Exceptions to this requirement may be approved for projects where multiple-residence housing is located on four (4) or six (6) lane streets carrying high traffic volumes. In such cases, the project may be oriented around courtyards or open space.
3. Projection or Recess. Building entrances and individual exterior unit entrances shall have a roofed projection (such as a porch) or recess with a minimum depth of at least five (5) feet and minimum horizontal area of 50 square feet.
[image omitted; see the official code]
FIGURE 11-5-6.D(1): BUILDING ENTRANCE PROJECTION OR RECESS
E. Access, Circulation, and Parking. The parking and circulation system within each development shall accommodate the movement of vehicles, bicycles, pedestrians and transit, throughout the proposed development and to and from surrounding areas, safely and conveniently, and shall contribute to the attractiveness of the development.
1. Directness and Continuity. Walkways within the site shall be located and aligned to provide continuous connection between buildings, and various site amenities such as play areas, club houses, pools, mailboxes, etc. Walkways shall not be located and aligned solely based on the outline of a parking lot configuration that does not provide such direct pedestrian access.
2. Off-site Access.
a. Walkways shall provide direct connections to trails, parks, schools, transit stops or other public amenities adjacent to the development.
b. Drive aisles leading to main entrances shall have walkways on both sides of the drive aisle.
3. Parking Area Design.
a. Parking areas shall be located to the side or rear of buildings, except visitor parking may be located between a building and the adjacent street.
b. The total frontage of parking areas visible from the street, including visitor parking, shall not exceed 30% of the lot frontage.
[image omitted; see the official code]
FIGURE 11-5-6.E(1): PARKING AND
GARAGE FRONTAGE LIMITATION
4. Location of Parking Spaces.
a. Tenant Parking. Required parking spaces shall be arranged to provide at least one (1) parking space per unit within 200 feet of the dwelling units they are intended to serve.
b. Guest Parking. Guest parking spaces shall be distributed proportionally to the dwelling unit locations that they are intended to serve.
5. Attached Garages.
a. In one (1) story buildings that include livable floor area, walls containing garage doors shall be set back a minimum of three (3) feet from the front façade of the building.
b. In multi-story buildings that include livable floor area, garage doors located below upper-story living space shall be recessed at least three (3) feet from the upper story facade.
c. When multiple garage doors are located within one (1) building, the maximum number of garage doors adjacent to one another shall be limited to three (3), unless there is a break in the building façade between garage doors consisting of a projected building entrance or a recess at least six (6) feet wide and three (3) feet deep.
6. Detached Garages.
a. Detached garages shall use exterior materials, colors, roof forms, roof materials, and architectural details that are the same as the principal buildings on the lot or within the development.
b. Perimeter garages that face public right-of-way or private property shall be designed in accordance with Subsections B and C above.
(Ord. No. 5996, § 1, 3-9-26)