§ 28-86 — Deletions and amendments to the 2021 International Energy Conservation Code
Code of Ordinances, City of Denton, Texas (Supp. No. 37, Update 1: codified through Ordinance No. 26-296 adopted March 24, 2026) · Denton City Code § 28-86
Corpus is an independent public-information project, not the official City of Denton website. Stable reference: corpuslaw.us/code/7731e510-294f-4dd0-9599-b2d138084c63
Section 28-86. - Deletions and amendments to the 2021 International Energy Conservation Code.
1. Section C101.1. is deleted in its entirety and replaced with the following: C101.1 Title. These regulations shall be known as the Energy Conservation Code of the City of Denton, hereinafter referred to as "this code." 2. A new Section C102.1.2 is added, to read as follows: C102.1.2 Alternative compliance. A building certified by a national, state, or local accredited energy efficiency program and determined by the Energy Systems Laboratory to be in compliance with the energy efficiency requirements of this section may, at the option of the Code Official, be considered in compliance. The United States Environmental Protection Agency's Energy Star Program Certification of energy code equivalency shall be considered in compliance. 3. Section C110 Board of Appeals, is deleted in its entirety and replaced by the following: C110. General. In order to hear and decide appeals of orders, decisions or determinations made by the building official, code official, or fire marshal relative to the application and interpretation of the requirements of this Code and all other applicable codes of the City of Denton, there shall be a health and building standards commission. 4. Section C402.5.2 is deleted in its entirety and replaced by the following: C402.5.2 Dwelling and sleeping unit enclosure testing. The building thermal envelope shall be tested in accordance with ASTM E779. ANSI/RESNET/ICC 380, ASTM E1827 or an equivalent method approved by the code official. The measured air leakage shall not exceed 0.30 cfm/ft 2 (1.5 L/s m 2 ) of the testing unit enclosure area at a pressure differential of 0.2 inch water gauge (50 Pa). Where multiple dwelling units or sleeping units or other occupiable conditioned spaces are contained within one building thermal envelope, each unit shall be considered an individual testing unit, and the building air leakage shall be the weighted average of all testing unit results, weighted by each testing unit's enclosure area. Units shall be tested separately with an unguarded blower door test as follows: 1. Where buildings have fewer than eight testing units, each testing unit shall be tested. 2. For buildings with eight or more testing units, the greater of seven units or 20 percent of the testing units in the building shall be tested, including a top floor unit, a ground floor unit, a middle floor unit, and a unit with the largest testing unit enclosure area. For each tested unit that exceeds the maximum air leakage rate, an additional three units shall be tested, including a mixture of testing unit types and locations. 5. Section R101.1. is deleted in its entirety and replaced with the following: R101.1 Title. These regulations shall be known as the Energy Conservation Code of the City of Denton, hereinafter referred to as "this code." 6. A new Section R102.1.2 (N1101.4.1) is added, to read as follows: R102.1.2 (NHO1.4.1) Alternative compliance. A building certified by a national, state, or local accredited energy efficiency program and determined by the Energy Systems Laboratory to be in compliance with the energy efficiency requirements of this section may, at the option of the Code Official, be considered in compliance. The United States Environmental Protection Agency's Energy Star Program certification of energy code equivalency shall be considered in compliance. Regardless of the program or the path to compliance, each 1- and 2-family dwelling shall be tested for air and duct leakage as prescribed in Section R402.4.1.2 (N1102.4.1.2) and R403.3.3 (N1103.3.3) respectively. 7. Section R110 Means of Appeals, is deleted in its entirety and replaced by the following: R110. General. In order to hear and decide appeals of orders, decisions or determinations made by the building official, code official, or fire marshal relative to the application and interpretation of the requirements of this Code and all other applicable codes of the City of Denton, there shall be a health and building standards commission. 8. Section R202 (N1101.6) Definitions; add the following definitions: DYNAMIC GLAZING. Any fenestration product that has the fully reversible ability to change it performance properties, including U-factor, solar heat gain coefficient (SHGC), or visible transmittance (VT). PROJECTION FACTOR. The ratio of the horizontal depth of the overhang, eave or permanently attached shading device, divided by the distance measured vertically from the bottom of the fenestration glazing to the underside of the overhang, eave or permanently attached shading device. 9. Section R401.2.5 (NI 101.13.5) Additional Energy efficiency; deleted in its entirety. 10. Table R402.1.2 (N102.1.2) Maximum Assembly U-Factorsaand Fenestration Requirements, is deleted in its entirety (Footnotes to remain) and replaced by the following: Table R402.1.2 MAXIMUM ASSEMBLY U-F ACTORSaAND FENESTRATION REQUIREMENTS Climate Zone | Fenestration U-Factor f | Skylight U- Factor | Glazed Fenestration SHGC d, e | Ceiling U- Factor | Wood Frame Wall U-Factor | Mass Wall U- Factor b | Floor U-Factor | Basement Wall U-Factor | Crawl Space Wall U-Factor 3 | 0.32 | .55 | 0.25 | 0.029 | 0.060 | 0.098 | 0.047 | 0.091° | 0.136 For SI: 1 foot = 304.8 mm. (Footnotes to remain) 11. Table R402.1.3 (N 1102.1.3) Insulation Minimum R-Values and Fenestration Requirements by Componenta, is deleted in its entirety and replaced by the following: TABLE R402.1.3 INSULATION MINIMUM R-VALUES AND FENESTRATION REQUIREMENTS BY COMPONENT Climate Zone | Fenestration U-Factor f | Skylight U-Factor | Glazed Fenestration SHGC d, e | Ceiling R Value | Wood Frame Wall R Value | Mass Wall U-Value c, g | Floor R Value | Basement Wall R Value | Slab R-Value d & Depth | Crawl Space Wall R Value 3 | 0.32 | .55 | 0.25 | 42 | 19 or 13+3 ci or 0+15 | 8/13 | 19 | 5 ci or 13 f | 0 | 5 ci or 13 f For SI: 1 foot = 304.8 mm. (Footnotes to remain) 12. A new Section R402.4.1.4 is added, to read as follows: R402.4.1.4 Sampling options for R2 multifamily dwelling units. For buildings with eight or more testing units that must be tested as required by R402.4.1.2 or R402.4.1.3, the greater of seven units or 20 percent of the testing units in the building shall be tested, including a top floor unit, a ground floor unit, a middle floor unit, and a unit with the largest testing unit enclosure area. For each tested unit that exceeds the maximum air leakage rate, an additional three units shall be tested, including a mixture of testing unit types and locations. Where buildings have fewer than eight testing units, each testing unit shall be tested. 13. Section R402.4.6 Electrical and communication outlet boxes (air-sealed boxes), is deleted in its entirety and replaced by the following: R402.4.6 Electrical and communication outlet boxes (air-sealed boxes). Electrical and communication outlet boxes installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces. 14. A new Section R403.3.8 is added, to read as follows: R403.3.8 Sampling options for R2 multifamily dwelling units. For buildings with eight or more testing units that must be tested as required by R403.3.5, the greater of seven units or 20 percent of the testing units in the building shall be tested, including a top floor unit, a ground floor unit, a middle floor unit, and a unit with the largest testing unit floor area. For each tested unit that exceeds the maximum duct leakage rate, an additional three units shall be tested, including a mixture of testing unit types and locations. Where buildings have fewer than eight testing units, each testing unit shall be tested. 15. A new Section R403.6.4 is added, to read as follows: R403.6.4 Sampling options for R2 multifamily dwelling units. For buildings with eight or more testing units that must be tested as required by R403.6.3, the greater of seven units or 20 percent of the testing units in the building shall be tested, including a top floor unit, a ground floor unit, a middle floor unit, and a unit with the largest testing unit floor area. For each tested unit that does not meet the minimum ventilation rate, an additional three units shall be tested, including a mixture of testing unit types and locations. Where buildings have fewer than eight testing units, each testing unit shall be tested. 16. Section R404.2 Interior Lighting Controls; deleted in its entirety. 17. Section R405.2 Performance-based compliance., is deleted in its entirety and replaced by the following: R405.2 Performance-based compliance. Compliance based on total building performance requires that a proposed design meets all of the following: 1. The requirements of the sections indicated within Table R405.2. 2. The building thermal envelope greater than or equal to levels of efficiency and solar heat gain coefficients in Table R402.1.1 or R402.1.3 of the 2009 Inter national Energy Conservation Code. 3. An annual energy cost that is less than or equal to the annual energy cost of the 2021 standard reference design or 8% less than the annual energy cost of the 2018 standard reference design. Energy prices shall be taken from a source approved by the code official, such as the Department of Energy, Energy Information Administration's State Energy Data North Central Texas Council of 5 Governments Amendments Approved October 2021. System Prices and Expenditures reports. Code officials shall be permitted to require time-of-use pricing in energy cost calculations. Exception: The energy use based on source energy expressed in Btu or Btu per square foot of conditioned floor area shall be permitted to be substituted for the energy cost. The source energy multiplier for electricity shall be 3.16. The source energy multiplier for fuels other than electricity shall be 1.1. 18. Table R406.5 (NI 106.5) MAXIMUM ENERGY RATING INDEX; is deleted in its entirety and replaced by the following: TABLE R406.5 (N1106.5)1MAXIMUM ENERGY RATING INDEX CLIMATE ZONE | EFFECTIVE DATES | ENERGY RATING INDEX 3 | Until August 31, 2022 | 63 3 | September 1, 2022 to August 31, 2025 | 59 3 | September 1, 2025 to August 31, 2028 | 57 3 | September 1, 2028 | 55 19. Section R408 ADDITIONAL EFFICIENCY PACKAGE OPTIONS; deleted in its entirety.
(Ord. No. 22-661, § 1, 4-5-22)
Ask a question about Denton law
Corpus searches the Denton sections it holds and shows the ones that match, with their citations. Free, no sign-in.