Effluent limitations attainable by the application of the best practicable control technology currently available (BPT).
40 C.F.R. § 432.82
in effectExcept as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the following effluent limitations representing the application of BPT:
(a) Facilities that generate no more than 50 million pounds per year of finished products must achieve the following effluent limitations:
Effluent Limitations
[BPT]
Regulated
parameter
Maximum daily
1
Maximum monthly avg.
1
BOD50.620.31
Fecal Coliform(
2)(
3)
O&G
40.220.11
TSS0.740.37
1 Pounds per 1000 lbs (or g/kg) of finished product.
2 Maximum of 400 MPN or CFU per 100 mL at any time.
3 No maximum monthly average limitation.
4 May be measured as hexane extractable material (HEM).
(b) Facilities that generate more than 50 million pounds per year of finished products must achieve the limitations for BOD5, fecal coliform, O&G, and TSS specified in paragraph (a) of this section.