29-6. - International Residential Code adopted.

The City Council of Chandler adopts by reference the International Residential Code, 2024 edition, ("IRC") and incorporates it herein as if fully set out in this Article VI of Chapter 29 with the additions, insertions, deletions, and changes set forth herein. The term "code" or "IRC" without further description when used in the portions of the IRC which are not amended and in this Article VI of Chapter 29 shall mean the IRC as amended herein by the additions, insertions, deletions, and changes set forth and adopted herein. Whenever the code refers to other publications of the International Code Council, which have been adopted by the City, such references shall be to the version of the publications as amended by the City. 29-6.1. Subsection R101.1 "Title" is hereby amended by inserting The City of Chandler, Arizona as Name of Jurisdiction. 29-6.2. Subsection R102.2 "Other laws" is hereby amended by adding the following provisions to the end thereof: Additionally, the Building Official will enforce the provisions of such other laws when mandated by State or Federal law. 29-6.3. Subsection R102.6 "Existing structures" is hereby amended by deleting reference to the International Property Maintenance Code. 29-6.4. Subsection R103.1 "Creation of agency" is hereby amended by inserting Development Services Department as name of department. 29-6.5. Subsection R105.2 "Work exempt from permit" "Building" is hereby amended by deleting item 1 in its entirety and replacing it with a new item 1 as follows: 1. One-story detached accessory structures, provided that the floor area does not exceed 120 square feet (11.15 m2) and the height measured at the highest point does not exceed 7 feet (2134 mm) with option up to a maximum of 9 feet (2743 mm) with setbacks at a ratio of 2 additional feet of setback for each additional 1 foot of building height. 29-6.6. Subsection R105.2 "Work exempt from permit" "Building" is hereby amended by deleting item 7 in its entirety and replacing it with a new item 7 as follows: 7. Prefabricated swimming pools that are less than 18 inches (457 mm) deep. 29-6.7. Subsection R105.2 "Work exempt from permit" is hereby amended by adding items to each work category as follows: Building: 11. Replacement of a roof cover where the replacement roof covering classification is equal to or greater than the existing roof covering classification and does not increase the loads upon the structural frame. 12. Special cases allowed by the Building Official for work of a similar nature and complexity as those items listed above. Electrical: 6. Repair or replacement of motors, transformers, overcurrent devices or equipment affixed to a Group R-3 occupancy where the replaced or repaired equipment is of the same rating as the existing equipment, is placed in the same location as the existing equipment and is labeled as defined in this Code. 7. Special cases as allowed by the Building Official for work of a similar nature and complexity as those items listed above. Gas: 4. Replacement of gas water heating equipment where the replacement equipment is of equal or lesser BTU capacity and is placed in the same location as the existing equipment. 5. Replacement of gas pool or spa heating equipment where the replacement equipment is of equal or lesser BTU capacity and is placed in the same location as the existing equipment. 6. Replacement of gas air-conditioning equipment, direct vent equipment, furnaces, and log lighters where the replacement equipment is of equal or lesser BTU capacity and is placed in the same location as existing equipment. 7. Special cases as allowed by the Building Official for work of a similar nature and complexity as those items listed above. Mechanical: 9. Replacement of evaporative coolers where the replacement equipment is of equal or lesser airflow (cfm) and is placed in the same location as the existing evaporative cooler. 10. Special cases as allowed by the Building Official, for work of a similar nature and complexity as those items listed above. Plumbing: 3. Replacement of water conditioning or treating equipment where the replacement equipment is of equal or lesser treatment capacity and is placed in the same location as the existing equipment. 4. Replacement of solar pool and spa heating equipment where the replacement equipment is of equal or lesser heating capacity and is placed in the same location as the existing equipment. 5. Replacement of electric water heating equipment where the replacement equipment is of equal or lesser amperage rating and is placed in the same location as the existing equipment. 6. Special cases as allowed by the Building Official for work of a similar nature and complexity as those items listed above. 29-6.8. Subsection R105.3.1 "Action on application" is hereby amended by adding the following provisions to the end of the first paragraph thereof: A permit may be issued solely after applicant has satisfied all applicable City of Chandler ordinances and requirements. 29-6.9. Subsection R105.5 "Expiration" is hereby amended by adding a new Subsection R105.5.1 to read as follows: R105.5.1 Reinstatement. The Building Official is authorized to reinstate a permit that has expired upon payment of a reinstatement fee provided: 1. The permit has not been expired for more than one year and, 2. Code requirements that would affect the project have not changed. 29-6.10. Subsection R108.2 "Schedule of Permit Fees" is hereby deleted in its entirety and replaced with a new Subsection R108.2 to read as follows: R108.2. Schedule of Permit Fees. Permit fees, if any, shall be adopted by the City by resolution. 29-6.11. Subsection R309.2 "One- and two-family dwellings automatic sprinkler systems" is hereby deleted in its entirety. 29-6.12. Subsection N1101.4 (R104.1.1) "Above code programs" is hereby amended by adding a new Subsection N1101.4.1 as follows: N1101.4.1 RESNET testing & inspection protocol. The Residential Energy Services Network (RESNET) Mortgage Industry National Home Energy Rating System Standards Protocol for third party testing and inspections, shall be deemed to meet the requirements of sections N1102.5.1, N1102.5.1.2 and N1103.3.5 and shall meet the following conditions: 1. Third party testing and inspections shall be completed by RESNET certified raters or rating field inspectors and shall be subject to RESNET quality assurance field review procedures. 2. Sampling in accordance with chapter 6 of the RESNET standards shall be performed by raters or rating field inspectors working under a RESNET accredited sampling provider. 3. Third party testing is required for the following items: a. N1102.5.1 — Building Envelope - Thermal and air barrier checklist b. N1102.5.1.2 — Testing - Air leakage rate c. N1103.3.5 — Sealing - Duct tightness 4. The other requirements identified as "mandatory" in Chapter 11 shall be met. 5. Alternate testing and inspection programs and protocols shall be allowed when approved by the Building official. 29-6.13. Subsection N1103.3.7 (R403.3.7) "Duct system testing" is hereby amended by adding one new exception to read as follows: Exceptions: 4. A duct air-leakage test shall not be required where the ducts and air handlers are entirely within the building thermal envelope. 29-6.14. Subsection N1105.3 (R405.3) "Compliance documentation" is hereby amended by replacing "before a certificate of occupancy is issued" in the end of the item 2 with "to the building owner". 29-6.15. Table N1106.5 (R406.5) "Maximum Energy Rating Index" is hereby amended by replacing energy rating index of "51" with "57" in the climate zone 2. 29-6.16. Section N1108 (R408) "Additional Efficiency Requirements" is hereby deleted in its entirety and Section N1108 (R408) is hereby reserved. 29-6.17. Subsection N1110.2.5 (R502.2.5) "Additional efficiency credit requirements for additions" is hereby deleted in its entirety. 29-6.18. Subsection N1111.1.5 (R503.1.5) "Additional efficiency credit requirements for substantial improvements" is hereby deleted in its entirety. 29-6.19. Subsection E3902.2 "Garage and Accessory Building Receptacles" is hereby amended by adding an exception as follows: Exception: Receptacles that are not readily accessible. 29-6.20. Subsection E3902.3 "Outdoor receptacles" is hereby amended by adding an exception as follows: Exception: Plug receptacles that are designed to be used for powering listed air conditioning, heating or cooling equipment. 29-6.21. Subsection E3902.14 "Outdoor outlets" Exceptions: 3 is hereby amended to delete the second sentence and read as follows: Exceptions: 3. GFCI protection shall not be required for listed HVAC equipment.

(Ord. No. 3409, § 7, 1-23-03; Ord. No. 3610, 1-27-05; Ord. No. 4082, § 10, 8-28-08; Ord. No. 4303, § 7, 5-26-11, eff. 7-1-11; Ord. No. 4452, § 7, 6-27-13, eff. 8-1-13; Ord. No. 4700, § 6, 5-12-16, eff. 7-1-16; Ord. No. 4847, § 3(Exh.), 12-10-18, eff. 7-1-19; Ord. No. 4993, § 3(Exh.), 2-24-22, eff. 7-1-22; Ord. No. 5108, § 3(Exh.), 12-9-24, eff. 7-1-25)

Ask a question about Chandler law

Corpus searches the Chandler sections it holds and shows the ones that match, with their citations. Free, no sign-in.