For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 71.6 — PVA lighting requirements

Code of Ordinances of the City of Huntsville, Alabama (Supp. No. 30 (codified through Ord. No. 26-196, adopted March 12, 2026) with enacted ordinances through Ord. No. 26-837 (September 24, 2026) applied from official council minutes and ordinance copies) · Huntsville Code of Ordinances, App. A, art. 71, § 71.6

Corpus is an independent public-information project, not the official City of Huntsville website. Stable reference: corpuslaw.us/code/78c780df-b1fc-4588-acf5-2ca441fc3d42

71.6. - PVA lighting requirements.

A detailed lighting plan for all PVAs having 15 or more parking spaces or containing at least 5,000 square feet of PVA must be submitted with the construction and landscape plans. 71.6.1. The lighting plan shall be drawn on the border of the submitting professional and shall clearly define the property lines and the zoning classifications for all adjacent properties. The lighting plan shall provide the following information: (1) The type of lamp to be used in each fixture, including the manufacturer's name and part number, lamp wattage, lumen output, and a copy of the manufacturer's lamp specifications; (2) Pole heights and locations; (3) The type of fixtures, including the manufacturer's name and model number, wattage and light loss factor meeting the standards in section 71.6.3(2), a picture of the fixture, and the IES file name; (4) Point-to-point photometric calculations at intervals of not more than ten feet at ground level demonstrating that the plan will provide a uniform intensity of lighting on vehicular surfaces in conformance with the requirements of section 71.6.3 below; (5) The area of each photometric calculation, including an extra calculation to identify the light level produced at the property line, and all data used in each calculation; and (6) The stamp of the qualified registered Alabama professional. 71.6.2. All exterior lighting fixtures shall be: (1) Protected by a weather and vandal resistant covering; (2) Located and fitted with appropriate cutoffs, if necessary, to prevent the light level on any adjoining roadway or residential property line from exceeding one footcandle; (3) Aimed so that they do not exceed an angle of 45 degrees out from the base of the pole when using floodlights; (4) Installed on poles 30 feet or less in height, unless the PVA exceeds 25,000 square feet; in such cases, poles exceeding 30 feet, as measured from the finished grade to the bottom of the fixture, may be used if it is demonstrated that all the requirements of this section can be met; and (5) Shielded so as to prevent glare on adjacent properties and rights-of-way. 71.6.3. PVA lighting shall be designed and installed in compliance with the following standards: _____ (1) Illumination requirements for PVAs as measured at ground level: TYPE OF PVA | REQUIRED MINIMUM LIGHT LEVEL | MAXIMUM/MINIMUM UNIFORMITY RATIO* Nonresidential and Residential Surface PVAs | 1 footcandle | 10:1 Parking Garages and Underground Parking | 5 footcandles | 4:1 Parking Garages and Underground Parking using LED source | 3 footcandles | 4:1 Garage Stairwells | 10 footcandles | NA Garage Rooftop Surfaces | 1 footcandle | 10:1 Nonresidential and Residential Surface PVAs using LED source | 0.4 footcandles | 8:1 * The highest horizontal illuminance area, divided by the lowest horizontal illuminance point or area should not be greater than the ratio shown. The maximum/minimum ratio must be calculated only for the area within the PVA; maximum light level at the right of way and at property lines shall also be shown. (2) Standards for Light Loss Factors: | METAL HALIDE | HIGH PRESSURE SODIUM | MERCURY VAPOR | LED* Light Loss Factor | 0.6 to 0.8 | 0.8 to 0.9 | 0.7 to 0.8 | 1.00 to 0.96 * Light loss factor of 1.00 can only be substantiated when luminaires are designed with "fail-up" technology when a single lighting element fails the luminaire responds by auto increasing the output of the remaining LEDs or when luminaires have inter-changeable light engines making circuit boards replaceable or interchangeable upon group failure. _____ 71.6.4. All required lighting shall be installed and approved prior to issuance of a certificate of occupancy. The registered professional who stamped the plans shall certify by letter that the installation complies with the approved plans. The letter shall specify fixtures, wattages, pole heights, and any special requirements, such as rotation, angle, shielding or positioning of critical poles at property lines. For PVAs smaller than 6,000 square feet, a certification letter must be submitted only if requested by the city. 71.6.5. PVA lighting meeting the standards of [this] section 71.6. shall be utilized during all hours of operation between dusk and dawn.

(Ord. No. 99-206, § 6, 4-8-1999; Ord. No. 99-1020, § 16, 1-13-2000; Ord. No. 01-746, § 2, 10-25-2001; Ord. No. 11-897, § 1, 1-26-2012; Ord. No. 15-756, § 1, 11-19-2015)

Ask a question about Huntsville law

Corpus searches the Huntsville sections it holds and shows the ones that match, with their citations. Free, no sign-in.