22.930.040 - Exemptions and extensions
A. Buildings meeting one or more of the following conditions may apply for an exemption from complying with a single interval of tune-ups as required by this Chapter 22.930. Building owners shall demonstrate they meet a condition for exemption by submitting evidence of the condition to the OSE Director no later than 180 days before the tune-up compliance date as specified in Section 22.930.050, unless the Director determines otherwise. The OSE Director shall notify applicants within 45 days of receiving an exemption request on the determination of whether the exemption is granted. Conditions meeting an exemption include but are not limited to: 1. Buildings with a high certified ENERGY STAR score preceding the tune-up compliance date identified in Section 22.930.050, as determined by the Director; 2. Buildings that have received a green building certification that is equivalent to standards accepted in the industry for an efficiently operating building within the three years preceding the tune-up compliance date identified in Section 22.930.050. A green building certification could be equivalent to a Net-Zero Energy Certification from the International Living Future Institute or similar, as determined by the OSE Director; 3. Buildings that can show evidence of active monitoring and continuous commissioning, as determined by the Director; 4. Buildings that have participated in and successfully completed an approved utility retro-commissioning incentive program in the three years preceding the tune-up compliance date identified in Section 22.930.050; 5. Buildings that have completed a full retro- or re-commissioning procedure within the three years preceding the tune-up compliance date identified in Section 22.930.050, with documentation that building performance was optimized; 6. Buildings that can demonstrate energy savings of at least 15 percent in the three years preceding the tune-up compliance date identified in Section 22.930.050; 7. Buildings that have undergone an energy audit no less stringent than the ASHRAE Level II standard and implemented all of the no-cost/low-cost energy efficiency measures, defined as providing a simple payback of three years or less, identified in the audit in the three years preceding the tune-up compliance date identified in Section 22.930.050; 8. Buildings that can demonstrate early adopter compliance with the Washington Clean Buildings Performance Standard as defined in chapter 194-50 WAC, with documentation and verification as determined by the OSE Director by the mandated schedule for tune-ups and reporting compliance dates identified in Section 22.930.050; 9. Buildings scheduled to be demolished within one year of the date the building tune-up is due pursuant to Section 22.930.050, per documentation determined by the OSE Director; 10. Buildings that demonstrate financial distress, such as being owned by a financial institution though default of the borrower, or other conditions as determined by the OSE Director; 11. Buildings receiving their initial certificate of occupancy less than three years before the tune-up compliance date identified in Section 22.930.050; or 12. Buildings receiving approval for a second one-year extension, during the second tune-up compliance interval of 2023—2026 and after January 1, 2024, as determined by the OSE Director. B. The OSE Director may prescribe rules for requesting an exemption under this Chapter 22.930.
(Ord. 126959, § 11, 2023; Ord. 125002, § 1, 2016.)
Ask a question about Seattle law
Corpus searches the Seattle sections it holds and shows the ones that match, with their citations. Free, no sign-in.