Sec. 74-282. - Specific standards.
In all areas of the special flood hazard where base flood elevation data has been provided, the following provisions are required: (a) Non-residential construction. The elevation of new construction or substantial improvement of any non-residential building installed as a part of any water control features shall have the lowest floor, including basement, elevated to the greater of either; three feet above the base flood elevation or two feet above the highest observed flood. Should solid foundation perimeter walls be used to elevate a structure, openings sufficient to facilitate the unimpeded movements of floodwaters shall be provided. (b) Ancillary structures. Ancillary structures are allowed if designed and constructed to minimize and mitigate impact on the floodplain in a manner that will not result in a net loss in flood storage volume or otherwise violate the provisions of this article or the MRPA cerfiticate. (c) Elevated buildings. All new construction or substantial improvements of existing structures that include any fully enclosed area located below the lowest floor formed by foundation and other exterior walls shall be designed so as to be an unfinished or flood resistant enclosure. The enclosure shall be designed to equalize hydrostatic flood forces on exterior walls by allowing for the automatic entry and exit of floodwater. (1) Basic requirements for elevating structures. The following requirements apply to the elevation of any structure within the redevelopment area: a. Design and construction of elevated structures shall utilize methods and practices that minimize flood damage and current and future encroachment into the floodway and any historically modified floodplain; b. The elevation of the structure's lowest floor shall be the greater of either; three feet above the base flood elevation or two feet above the highest observed flood; c. Elevated structures shall be constructed with materials and utility equipment resistant to flood damage in accordance with FEMA Technical Bulletin "Flood Damage-Resistant Materials Requirements" August 2008, or as amended; d. The area below the lowest floor of an elevated structure shall be flood resistant, unfinished, and designed with piers or wall openings to facilitate the natural flow of floodwaters under the structure; e. The unfinished and flood-resistant area below the lowest floor shall remain unoccupied and shall only be used for parking vehicles, limited storage of maintenance equipment used in connection with the premises, or entry to the elevated area; f. Stormwater management facilities and grease traps with backflow prevention devices that are properly designed to be isolated from flood waters may be allowed; g. The interior portion of the area below the lowest floor shall not be partitioned or finished into separate rooms; provided however, the minimum area necessary for access to upper floors may be finished with flood damage-resistant materials in accordance with FEMA Technical Bulletin "Flood Damage-Resistant Materials Requirements" August 2008, or as amended; h. Elevated structures shall be anchored to prevent flotation, collapse or lateral movement of the structure; i. Heating and air conditioning equipment and components (including ductwork), electrical, ventilation, plumbing equipment (including water heater), and other service facilities shall be located at least three feet above the base flood elevation or two feet above the highest observed flood (whichever is greater) to prevent water from entering or accumulating within the components during conditions of flooding; j. Designs for complying with the requirements of this article shall be certified by either a professional engineer or architect; k. Landings and stairs that allow for the natural flow of floodwaters will be allowed for minimum entry access; l. If the proposed elevated structure is located in multiple flood zones or if multiple base flood elevations cross the site, the higher or most protective base flood elevation shall take precedence; m. The design shall provide for the drainage of floodwaters in not less than 72 hours pursuant to FEMA Technical Bulletin 1 (August 2008); and n. A file-stamped copy of an elevation certificate filed in the land records of the county in which the property is located shall be submitted to the commissioner prior to the issuance of a certificate of occupancy. This elevation certificate shall be prepared by a licensed surveyor and shall document the elevation of the lowest floor relative to mean sea level and compliance with the ordinance.
(Ord. No. 2021-61(21-O-0719), § 1, 12-15-21)
Ask a question about Atlanta law
Corpus searches the Atlanta sections it holds and shows the ones that match, with their citations. Free, no sign-in.