Sec. 27-183. - General district development standards.
TABLE 183. BUILDING PLACEMENT, HEIGHT, AND STREET ORDER STANDARDS
[image omitted; see the official code] | [image omitted; see the official code] | [image omitted; see the official code] | [image omitted; see the official code] | [image omitted; see the official code]
BUILDING PLACEMENT | BUILDING STREETWALL % WITHIN BTZ, BY STREET ORDER [5, 6, 7]
BUILD-TO ZONE (BTZ) | PRIMARY STREET FRONTAGE [PF] [8]
Build-to Zone [BTZ] | 0' min - 6' max [1] | Special Pedestrian Street ('A'-Street) | 85% min
SETBACK [2] | Transit & Mobility Priority Street ('B'-Street) | 60% min
Side Interior [SI] | 0' min | Standard Pedestrian & Service Street ('C'-Street) | 50% min
SECONDARY STREET FRONTAGE [SF] [8]
Rear [R] | 0' min | Special Pedestrian Street ('A'-Street) | 75% min
Transit & Mobility Priority Street ('B'-Street) | 50% min
Rear Alley [RA] | 3' min | Standard Pedestrian & Service Street ('C'-Street) | 25% min
TERTIARY/LOWER STREET FRONTAGE [TLF] [8]
Waterfront [W] [3,4] | 23' min | Transit & Mobility Priority Street ('B'-Street) | 30% min
Standard Pedestrian & Service Street ('C'-Street) | 20% min
MAXIMUM HEIGHT
CBD-1 or CBD-2 | [9]
Parapet wall | 5' above principal or accessory building height [10]
Elevator/mechanical housing, steeples, flag poles, widow's walk, cupolas, other architecturally integrated features | Exempt, except shall occupy no more than 30% of roof area [10]
PUBLIC OPEN AND GENERAL OPEN SPACE REQUIREMENTS
Total Open Space to be Provided | Public Open Space Provided at Grade [11] | Conditions for Open Space not at Grade
Minimum area required (SF): 10% of development parcel | Minimum 30% of Total Open Space must be placed at Grade and meet the definition of "Public Open Space" in sec. 27-43. | Areas provided on the building podium, open to the sky, shall be counted towards the overall open space requirement, but not towards the "public open space"
RIVERWALK (Also refer to sec. 27-181.5)
Within Waterfront [W] Setback | Emergency Vehicle Access
17' paved (includes 2' for bulkhead wall) Remaining area: landscape, appropriate furniture, etc. | Min clearance: 12' wide for pedestrians (i.e. sidewalk) at all times Min clearance: Increased to 20' wide for emergency vehicles [12]
PUBLIC ART (Also refer to sec. 27-181.4)
Required Contribution Rate | Maximum Fee | Benchmark to Pay Fee | Public Art Fund
Required for New Construction Only: 0.75% x total project development cost | $200,000.00 | Prior to issuance of certificate of occupancy | Fund consists of all payments for public art requirements within the Center City (CBD)
NOTES FOR TABLE 183 (continued)
BUILDING PLACEMENT NOTES:
[1] Build-to Zone (BTZ). The ground floor streetwall/facade of each building shall be placed within the Build-to-Zone (BTZ) for the percentage of the parcel frontage shown in this table. BTZ is measured from edge of required Public Realm Zone, or from parcel/property line if required Public Realm Zone is wholly accommodated within the right-of-way (public or private).
[2] Setback. The line/location that sets the minimum distance at which the building wall may be placed.
[3] Waterfront building setback shall be measured from the water's edge, as measured from the waterside face of the bulkhead.
[4] Refer to additional Waterfront Overlay and Riverwalk Standards set forth in sec. 27-181.5.
BUILDING STREETWALL NOTES:
[5] Building streetwall is that building façade designed for, placed within, and oriented to the BTZ.
[6] Minimum % of building streetwall/façade (ground floor) shall be built within the BTZ.
[7] All new building streetwalls/facades, including structured parking (freestanding or attached) shall be designed consistent with the streetwall standards and frontage types, set forth in Table 183.1, Tables 183.1A-E.
STREET ORDER NOTES:
[8] The Street Types A-C are in order from highest pedestrian-oriented design to lowest. Street Type A, when adjacent to development parcel, is always Primary Order Street. When Street Type A is adjacent and Street Type B is also adjacent, Street Type B is Secondary Order Street. Street Type B may also be Tertiary or Lower, when more than one (1) Type B is adjacent to the parcel. Street Type C is always a lower order street than Street Type A and/or B. Street Type C shall only be set as the Primary Order Street where Type C is the only street type adjacent to the development parcel.
MAXIMUM HEIGHTS NOTES:
[9] Structure heights shall be controlled by Airport Zoning Regulations and Airport Height Zoning Map as adopted and administered by the Hillsborough County Aviation Authority under the provisions of Chapter 333, Florida Statutes and Chapter 2012-234, Laws of Florida, as amended.
[10] Also refer to sec. 27-43 for specific definitions.
PUBLIC OPEN AND GENERAL OPEN SPACE NOTES:
[11] All area(s) provided on private property to meet the Public Realm Zone standards shall be counted towards the 30% "public open space" requirement. For properties in the Waterfront Overlay, a portion of the "public open space" provided must be located to create a pedestrian connection from the Public Realm Zone to the Waterfront Setback/Riverwalk.
RIVERWALK NOTES:
[12] Increased to 20' for emergency vehicles, where fire protection systems not provided for adjacent building (expanded zone is integrated with Riverwalk).
TABLE 183.1 GENERAL BUILDING STREETWALL DESIGN, FRONTAGE TYPES, BUILDING SIGNS
BUILDING SIGN STANDARDS
Category | Building Type | Sign Placement by Building Floor [1] | Maximum Area (SF) [3,4]
1-S | All Buildings | 1 st Floor [2] | 2 SF per 1 LF
2-S | 5 Floors or less | On face of highest Floor | 1.25 SF per 1 LF
3-S | 6 to 15 Floors | On face of highest Floor | 2 SF per 1 LF
4-S | 16 to 30 Floors | On face of highest Floor | 3 SF per 1 LF
5-S | 31 Floors and up | On face of highest Floor | 4 SF per 1 LF
Sign Notes: [LF] Linear feet; [SF] Square feet
[1] For multi-level buildings, sign area allowed for floors above 1 st floor, those signs shall be placed on the wall face of the highest floor of the building.
[2] Includes all allowed signs set forth in division 6 'signs' of this chapter.
[3] The maximum sign SF ratios are available for use based on the overall number of floors/levels of the building and may be oriented towards any frontage. All buildings are allowed the maximum under 1-S. Use the 'Category' column to identify allowable sign area ratio by total building floor/level count; ratios are not to be aggregated by segments or portions of floors (i.e. a 40-floor building is permitted to use max SF for 1-S and 5-S only, with the total from 5-S placed on the face of the 40 th floor). Example: 3 story building = 1-S (placed on allowable building surfaces for 1 st Floor) and 2-S placed on the face of the 3 rd floor.
[4] Sign area leftover from 1-S can be redistricted to the upper level building sign total.
[5] Projecting signs shall be allowed, providing the following specific regulations are met:
a. Projecting signs shall not project more than four (4) feet from the building wall to which the projecting sign is attached.
b. Projecting signs shall not be located above the roofline of the building.
c. The supporting hardware, unless incorporated as a decorative component of a projecting sign shall not be visible from the street or sidewalk.
d. Projecting signs shall not be constructed in violation of the public space encroachment limitations specified in this chapter or other applicable City Code.
e. Projecting signs shall not be erected closer than ten (10) feet from another projecting or marquee sign, except where two projecting signs are located on different frontages of the same building.
f. Projecting signs, when specifically allowed by this Code, which project over any public or private pedestrian way shall be elevated a minimum of nine (9) feet above such pedestrian way. Projecting signs, when specifically allowed by this Code, which project over any public or private street shall be elevated a minimum of sixteen (16) feet above such street.
[6] Subject to the maximum area requirements section above, each establishment with a main door entrance which faces a public street in a multiple-occupancy parcel shall be allowed the following:
i. One (1) building sign for each side of the establishment which faces a public street;
ii. One (1) marquee or canopy sign, as set forth in subsection (b)(7) below, may be substituted for each permitted building sign;
iii. One (1) awning sign per awning;
iv. One (1) hanging awning/canopy sign or projecting sign per establishment frontage; and
v. Signs displayed on a multi-occupancy parcel may be uniquely designed per tenant.
TABLE 183.1A "SHOPFRONT" FRONTAGE
Description and General Standards. A shopfront frontage is typical for single- or mixed-use commercial or office frontage. The façade is located within the Build-to-Zone pursuant to Table 183, with the pedestrian entrance at sidewalk grade. The façade may include an awning, shed roof, or gallery (structural canopy with no habitable building area above it) that covers the sidewalk. The facade has a substantial amount of glazing (transparency) at the sidewalk level. Recessed entrances are acceptable. All shopfront frontages shall comply with development standards set forth below:
[image omitted; see the official code] | "SHOPFRONT" FRONTAGE BY STREET TYPE
STREET TYPES | STATUS
A | Permitted; Preferred
B | Permitted
C | Permitted
REQUIREMENTS [3-6] | MINIMUM | MAXIMUM
Distance between Openings [A] [2] | 10' | 30'
Door Recess [B] | - | 10'
Height to Bottom of Window [C] | - | 2'
Transparency [1] | 70% | -
OPTIONAL ELEMENTS | MINIMUM | MAXIMUM
Awning or Marquee Depth [D] | 4' | 10'
Gallery Depth (clear) [D] | 8' | 10'
Awning, Marquee, Gallery Height (clear) [E] | 14' | -
NOTES:
[1] Transparency measured horizontally from edge to edge of wall plane and vertically between 2' and 15' above finished grade.
[2] Streetwall design shall include door openings at no more than 125' between openings along all street fronts. This shall include a minimum of one (1) door opening per property, to the primary street.
[3] Prohibit large expanses of opaque or blank walls. No blank walls of more than 25' in length are permitted without relief or protrusion of at least 6".
[4] Maintain the following: (i) the distinction between the upper and lower levels of the building with treatments such as cornice lines, changes in material, color, or fenestration pattern; and (ii) the cornice line of adjacent existing buildings, where applicable, to continue the definition of the public realm.
[5] Protect the integrity of the existing street grid by prohibiting connections that promote a continuous level of commercial uses above grade. This requirement shall not discourage tenant-serving commercial on any level of a building, so long as such commercial is placed at street level.
[6] Waterfront Overlay: A public entrance shall be oriented towards or placed on the Riverwalk. Rooftop mechanical equipment shall be screened from pedestrian view through the use of architectural enclosures designed as an integral part of the building architecture. To present an attractive roof-top/roof-deck, special consideration shall be given to the design treatment of all roof components, including terraces, or portions of the building.
TABLE 183.1B "ARCADE" FRONTAGE
Description and General Standards. This type is appropriate for single- or mixed-use commercial or office frontage. An arcade frontage is shopfront facade with an attached colonnade with habitable building space above, placed adjacent to the right-of-way. The shopfront and/or walkway is/are located within the Build-to-Zone pursuant to Table 183, to provide the required Public Realm Zone dimension. The facade has a substantial amount of glazing (transparency) at the sidewalk level. All arcade frontages shall comply with development standards set forth below:
[image omitted; see the official code] | "ARCADE" FRONTAGE BY STREET TYPE
STREET TYPES | STATUS
A | Permitted; Preferred
B | Permitted
C | Permitted
REQUIREMENTS [3-6] | MINIMUM | MAXIMUM
Distance between Openings [A] [2] | 10' | 30'
Door Recess [B] | - | 10'
Height to Bottom of Window [C] | - | 2'
Arcade Depth (clear) [D] | 10' | -
Arcade Height (clear) [E] | 15' | -
Spacing Between Columns (clear) [F] | 10' | -
Column Width (clear) [G] | - | 4'
Transparency [1] | 70% | -
NOTES:
[1] Transparency measured horizontally from edge to edge of wall plane and vertically between 2' and 15' above finished grade.
[2] Streetwall design shall include door openings at no more than 125' between openings along all street fronts. This shall include a minimum of one (1) door opening per property, to the primary street.
[3] Prohibit large expanses of opaque or blank walls. No blank walls of more than 25' in length are permitted without relief or protrusion of at least 6".
[4] Maintain the following: (i) the distinction between the upper and lower levels of the building with treatments such as cornice lines, changes in material, color, or fenestration pattern; and (ii) the cornice line of adjacent existing buildings, where applicable, to continue the definition of the public realm.
[5] Protect the integrity of the existing street grid by prohibiting connections that promote a continuous level of commercial uses above grade. This requirement shall not discourage tenant-serving commercial on any level of a building, so long as such commercial is placed at street level.
[6] Waterfront Overlay: A public entrance shall be oriented towards or placed on the Riverwalk. Rooftop mechanical equipment shall be screened from pedestrian view through the use of architectural enclosures designed as an integral part of the building architecture. To present an attractive roof-top/roof-deck, special consideration shall be given to the design treatment of all roof components, including terraces, or portions of the building.
TABLE 183.1C "FORECOURT" FRONTAGE
Description and General Standards. This type is appropriate for single- or mixed-use commercial, office, or residential frontage. A forecourt is a recessed courtyard with street-facing edges providing additional transparency. For this frontage, the 'streetwall(s)' is(are) located within the Build-to Zone, pursuant to Table 183. The 'interior forecourt wall' is recessed to form an open-air court (typically uncovered). The forecourt is suitable for passive seating/gathering, outdoor dining, public art, gardens, formal entries, etc. All forecourt frontages shall comply with development standards set forth below:
[image omitted; see the official code] | "FORECOURT" FRONTAGE BY STREET TYPE
STREET TYPES | STATUS
A | Permitted; Preferred
B | Permitted; Preferred
C | Permitted
REQUIREMENTS [3-10] | MINIMUM | MAXIMUM
Height to Bottom of Window [A] | - | 2'
Forecourt Width (clear) [B] | 12' | ⅓ of building length
Forecourt Depth (clear) [C] | 12' | 50'
Seating Wall Height [D] [2] | 2' | 3'
Streetwall Transparency [1,6] | 30% | -
Interior Forecourt Wall Transparency [1,6] | 50% | -
NOTES:
[1] Transparency measured horizontally from edge to edge of wall plane and vertically between 2' and 15' above finished grade.
[2] Seat-wall(s) within forecourt area limited to heights above. A seat-wall may be placed at the edge of the Public Realm Zone to define the forecourt space.
[3] The forecourt space is counted as frontage.
[4] The forecourt may be elevated behind a retaining wall at or near the front lot line with entry steps to the court.
[5] ADA access is required to the forecourt from the Public Realm Zone, regardless of final design.
[6] Streetwall and Interior Forecourt Wall shall include at least one (1) door opening each, for each development.
[7] Prohibit large expanses of opaque or blank walls. No blank walls of more than 15' in length are permitted without relief or protrusion of at least 6".
[8] Maintain the following: (i) the distinction between the upper and lower levels of the building with treatments such as cornice lines, changes in material, color, or fenestration pattern; and (ii) the cornice line of adjacent existing buildings, where applicable, to continue the definition of the public realm.
[9] Protect the integrity of the existing street grid by prohibiting connections that promote a continuous level of commercial uses above grade. This requirement shall not discourage tenant-serving commercial on any level of a building, so long as such commercial is placed at street level.
[10] Waterfront Overlay: A public entrance shall be oriented towards or placed on the Riverwalk. Rooftop mechanical equipment shall be screened from pedestrian view through the use of architectural enclosures designed as an integral part of the building architecture. To present an attractive roof-top/roof-deck, special consideration shall be given to the design treatment of all roof components, including terraces, or portions of the building.
TABLE 183.1D "STOOP" FRONTAGE
Description and General Standards. This type is appropriate for single- or mixed-use office or residential frontage. A stoop is an elevated entry placed close to the Public Realm Zone with small front yards. For a stoop, the façade is located within the Build-to Zone, subject to applicable requirements. The façade includes an elevated landing with stairs, (with appropriate ADA accessibility for non-residential uses), that is placed at or near the edge of the sidewalk. The stoop may include a cover for weather protection (i.e. roof, awning). All stoop frontages shall comply with development standards set forth below:
[image omitted; see the official code] | "STOOP" FRONTAGE BY STREET TYPE
STREET TYPES | STATUS
A | Permitted; Preferred
B | Permitted
C | Permitted
REQUIREMENTS [3-6] | MINIMUM | MAXIMUM
Stoop Width (clear) [A] | 6' | 12'
Stoop Landing Depth (clear) [B] | 4' | 10'
Stoop Height (clearance above landing) [C] | 8' | -
Stoop Landing Elevation [2] [D] | 1.5' | -
Front Separator Wall Height [E] | 2' | 4'
Distance between Openings/Stoops [F] [2] | 10' | 40'
Transparency [1] | 30% | -
NOTES:
[1] Transparency measured horizontally from edge to edge of unit wall plane and vertically between [D] and 15' above [D]. ([D] as designed for development)
[2] Streetwall design shall include door openings at no more than 125' between openings along all street fronts. This shall include a minimum of one (1) door opening per property, to the primary street.
[3] Prohibit large expanses of opaque or blank walls. No blank walls of more than 25 feet in length are permitted without relief or protrusion of at least 6 inches.
[4] Maintain the following: (i) the distinction between the upper and lower levels of the building with treatments such as cornice lines, changes in material, color, or fenestration pattern; and (ii) the cornice line of adjacent existing buildings, where applicable, to continue the definition of the public realm.
[5] Protect the integrity of the existing street grid by prohibiting connections that promote a continuous level of commercial uses above grade. This requirement shall not discourage tenant-serving commercial on any level of a building, so long as such commercial is placed at street level.
[6] Waterfront Overlay: A public entrance shall be oriented towards or placed on the Riverwalk. Rooftop mechanical equipment shall be screened from pedestrian view through the use of architectural enclosures designed as an integral part of the building architecture. To present an attractive roof-top/roof-deck, special consideration shall be given to the design treatment of all roof components, including terraces, or portions of the building.
TABLE 183.1E "GARAGE" FRONTAGE
Description and General Standards. This type is appropriate for vehicle parking and must include single- or mixed-use commercial, office, or residential uses at the street level. All of the frontage types set forth in Tables 183.1A-D may be incorporated at the ground level. All garage frontages shall comply with development standards set forth below:
[image omitted; see the official code] | "GARAGE" FRONTAGE BY STREET TYPE
STREET TYPES | STATUS
A | Prohibited [1]
B | Permitted
C | Permitted; Preferred
REQUIREMENTS [1-6] | MINIMUM | MAXIMUM
Active Space Depth [A] | 25' | -
Active Space Width [B] | ½ of building length | -
Height to Bottom of Window [C] | - | 2'
Transparency [2] | 70% | -
WITHIN WATERFRONT OVERLAY (Refer to sec. 27-181.5)
PARKING STRUCTURES | SERVICE, LOADING AREAS; RELATED ACCESS DRIVES
VEHICLE ACCESS PROHIBITED: | From orienting towards the Riverwalk | PLACEMENT, DESIGN, SCREENING: | Located to minimize visibility of these components from Public Realm Zone and Riverwalk
From being located within the Waterfront Setback (Table 183)
STREETWALL & WATERFRONT-ORIENTED FACADE DESIGN: | Must be architecturally integrated with the principal structure
Conceal vehicles from grade-level views | Screened to provide a minimum 50% opacity at time pedestrian view
Utilize landscaping elements or other design features to soften the appearance of the exterior façade
NOTES:
[1] On Street Type A, structural parking garages are required to design to either the "Shopfront" (Table 183.1A) or "Arcade" (Table 183.1B) frontage. Vehicle access is prohibited on/to/from Street Type A, unless all other vehicle access option(s) is(are) prohibited and/or the development has no other street frontage.
[2] Transparency measured horizontally from edge to edge of wall plane and vertically between 2' and 15' above finished grade. Transparency may differ if an alternate frontage type is used at the ground level (refer to transparency requirement of the applicable frontage type proposed.)
[3] Streetwall design shall include a minimum of one (1) door opening per property, to the primary street.
[4] Prohibit large expanses of opaque or blank walls. No blank walls of more than 25' in length are permitted without relief or protrusion of at least 6 inches.
[5] Maintain the following: (i) the distinction between the upper and lower levels of the building with treatments such as cornice lines, changes in material, color, or fenestration pattern; and (ii) the cornice line of adjacent existing buildings, where applicable, to continue the definition of the public realm.
[6] Protect the integrity of the existing street grid by prohibiting connections that promote a continuous level of commercial uses above grade. This requirement shall not discourage tenant-serving commercial on any level of a building, so long as such commercial is placed at street level.
(Ord. No. 2016-79, § 1(Exh. A), 5-26-2016; Ord. No. 2022-155, § 4, 9-1-2022; Ord. No. 2022-170, § 1, 10-6-2022)