§ 49-1141 — Type I interceptors for flammable waste
Omaha Municipal Code (Supp. No. 100, Update 2: codified through Ordinance No. 44760, enacted August 4, 2026) · Omaha Municipal Code § 49-1141
Corpus is an independent public-information project, not the official City of Omaha website. Stable reference: corpuslaw.us/code/7a06fdbf-3634-42b6-9845-33d9bb976e0e
Sec. 49-1141. - Type I interceptors for flammable waste.
There shall be a minimum of one floor drain or one trench drain for each 1,500 square feet of service and repair area or fraction thereof. For parking garages there shall be a minimum of one floor drain or one trench drain for each 3,000 square feet. Where the parking area is sloped as part of a ramp then one drain or one trench drain at the base of each ramp (see Figure 49-1141). Drains on the top level of the parking area shall be sized according to article XII. Type I sealed interceptors for flammable waste shall meet the following requirements (see Figure 49-1141): (a) Sizing: (1) Up to three, four-inch drains or 60 feet of trench drain shall be connected to an interceptor with a minimum 24 inches inside diameter and shall have a minimum depth below the water level of 24 inches. (2) Up to eight, four-inch drains or 160 feet of trench drain shall be connected to an interceptor with a minimum 30 inches inside diameter and shall have a minimum depth below the water level of 30 inches. (3) More than eight, four-inch drains or more than 160 feet of trench drain shall be connected to an interceptor with a minimum 36 inches inside diameter and shall have a minimum depth below the water level of 36 inches. (b) Shall be constructed of one of the following: (1) Cast iron. (2) Formed concrete 3,000 pound rated with a minimum reinforced wall thickness of four inches. (3) Reinforced concrete pipe meeting the requirements of section 49-828. (4) The board may approve interceptors constructed of fiberglass reinforced polyester or high density polyethylene provided the inlet and outlet shall permit the interceptors to be installed as shown in Figure 49-1140(c) and Figure 49-1141. (c) An airtight cover with a minimum clear opening of 22 inches securely attached to the top of the basin and designed to withstand traffic loads. (d) A minimum trap seal of eight inches with a full size cleanout. (e) A four-inch vent installed independently from the interceptor through the exterior wall no more than a maximum four feet above the interceptor and a minimum 18 inches from the ground to the opening. (f) The outlet shall be protected from infiltration by either an approved cover or a return bend at the wall penetration. (g) Have a minimum four-inch inlet and outlet waste.
(Ord. No. 40524, § 1, 10-20-15; Ord. No. 42654, § 39, 8-13-21)
Ask a question about Omaha law
Corpus searches the Omaha sections it holds and shows the ones that match, with their citations. Free, no sign-in.