Sec. 34-608. - Plumbing and mechanical.

(a) Installation and maintenance of plumbing supply lines and equipment shall be in compliance with local codes and the Uniform Plumbing Code. At no time shall plumbing be arranged in a manner that may allow pollution or contamination of potable water supplies. General requirements are as follows: (1) Hot and cold running water shall be available at all times. (2) Restrooms shall be provided with adequate ventilation to prevent excessive condensation, mold or algae growth, or odors. (3) The drainage system shall be adequately vented to extend above the roof. (4) All fixtures shall be adequately and properly trapped. (5) Openings for the passage of plumbing shall be pest proof. (6) No fitting, connection, device or method of installation shall obstruct or constrict the flow of water, wastes, sewage or air in the drainage or venting system. (b) Inspected mechanical devices. Certification of inspection by the fire department shall be required for the following water heaters, boilers and pressure vessels: (1) Water heaters with heat input greater than 200,000 British Thermal Units per hour or 57.6 kilowatts if electric; (2) All boilers; and (3) Hot water storage tanks greater than 120-gallon capacity, and water temperatures exceeding 210 degrees Fahrenheit, and heat input greater than 200,000 BTU/hr. or 57.6 kW if electric; (4) Evidence of inspection and approval shall be posted on the premises. (c) Non-inspected mechanical devices. Water heaters and pressure vessels not required to be inspected and approved by the fire department: (1) Shall be rated for a minimum working pressure of 125 pounds per square inch. The maximum pressure allowed shall be permanently marked on all water heating units and holding tanks. (2) A separate valve or switch shall be provided to shut the fuel supply off to water heating units. (d) Safety devices. Devices to prevent the excessive buildup of heat and/or pressure in the vessel must be provided on water heaters and other pressure vessels. (1) Temperature and pressure (T&P) relief valves are required on or adjacent to hot water holding tanks but cannot be separated from the tank by a check valve or shutoff valve. (2) Temperature and pressure (T&P) relief valves are required on water heaters and must be installed so that the sensing element extends into the tank and monitors the temperatures in the top six inches of the tank. a. Relief valves shall bear imprints, plates or tags to indicate the specifications of the valve; b. BTU rating of the temperature component of the T&P relief valve must be equal to or greater than the input BTU of the vessel it serves; c. Pressure rating of the pressure component of the T&P relief valve must be equal to or less than the pressure rating of the vessel it serves. (e) Relief valve discharge pipes shall be made of rigid pipe approved for water distribution with a temperature rating of 210 degrees Fahrenheit or other materials approved by the manufacturer to be used for this purpose and: (1) Be the same diameter, or larger, as the relief valve outlet; (2) Be installed so as to drain by gravity flow and shall have no more than one elbow or be installed according to manufacturer's specifications; (3) Valves shall not be connected to the relief valve discharge pipe; and; (4) Shall not discharge so as to be a hazard or a potential cause of damage. (f) Backflow devices. All backflow devices used must meet local, state and federal codes. Potable water supplies shall be protected from sources of potential contamination. (1) The following shall be protected by reduced pressure zone (RPZ) backflow prevention assembly: boiler units, fire sprinkler systems with chemical additives, lawn sprinklers with facilities for injection of pesticides, herbicides or other chemicals, and pumped or re-pressurized cooling or heating systems. (2) The following shall be protected by a double-check valve assembly: establishment wide fire sprinklers not using chemical additives and lawn sprinklers without facilities for injection of pesticides, herbicides or other chemicals. (3) The following shall be protected by vacuum breakers: threaded faucets, flush valves and shower spray hoses. Commercial dishwashers and commercial laundry machines shall be protected by either a vacuum breaker or an air gap. (4) The following shall be protected by air gaps: relief valve discharge pipes from water heaters and water holding tanks, make-up waterlines for cooling towers, potable water inlets to all plumbing fixtures, water softeners, condensation waterlines and discharge lines from commercial laundry machines. Swimming pool feed lines shall be protected by either an air gap or double-check valve assembly. (5) The following shall be protected by air breaks: ice containers and ice machines. (6) Fire sprinklers plumbed into a potable water line over gas water heaters and/or furnaces shall not be required to install a backflow device unless required by local ordinance. (g) Propane systems. Liquid propane (LP) gas systems shall be tested for leaks on a yearly basis.

(Ord. No. 140032, § 4, 1-23-14)

Ask a question about Kansas City law

Corpus searches the Kansas City sections it holds and shows the ones that match, with their citations. Free, no sign-in.