For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 22.41.020 — Site Design & Layout

Long Beach Municipal Code (Supp. No. 53, Update 1: codified through Ordinance No. ORD-26-0027, enacted October 13, 2026) · Long Beach Municipal Code § 22.41.020

Corpus is an independent public-information project, not the official City of Long Beach website. Stable reference: corpuslaw.us/code/7b16f03b-9950-426b-bc98-6295811a396a

22.41.020 - Site Design & Layout.

1. Blank Walls. a. A blank wall is a continuous blank wall, without windows, doors, or any other architectural articulation. b. All blank walls over 20 feet shall be screened with landscaping appropriate to the height of the wall. The landscaping shall have a minimum landscape strip of 5 feet in depth. c. Buildings with ground-floor above 15 feet shall have landscaping to grow to a height of maturity of 10 feet to provide sufficient screening. d. Required landscaping areas required by section 22.41.040 must include trees or shrubs of a spacing of 20 feet or less. The landscaping must achieve a height of 10 feet at maturity. e. Interruptions in landscaping screening are permitted at building entrances and plazas to accommodate employee amenities. 2. Modulation. a. Modulation refers to creating variations in the facade (outer wall) of a building as a means of breaking up the apparent bulk of the continuous exterior walls. Modulation includes, but is not limited to, projections or recessions in the façade of at least 2 feet in depth. b. Building facades over 80 feet in length and over 2 stories in height shall provide modulation at a minimum of 15% of the Primary Façade Plane. c. The Primary Façade Plane is defined as the vertical plane with the greatest surface area above the ground floor. d. Modulation is not required to be continuous or open to the sky and may be recessed or projected. e. Additional façade breaks beyond the minimum required may count towards the modulation requirement. 3. Transparency. At least 15% of each façade facing a public street should be comprised of transparent openings unless otherwise prohibited by use-specific regulations. a. Transparent openings may include windows and doors with clear glass or façade openings with a minimum depth of 4 feet. b. Windows shall be recessed by at least 2 inches from the façade; flush windows may be allowed subject to the discretion of the Site Plan Review Committee. c. The use of mirrored or highly reflective glazing is prohibited. d. Semi-transparent or frosted treatments are permitted to shield up to 50% of the transparent opening to manage private or security needs. 4. Light Design for Safety a. In addition to the following standards, all lighting shall be consistent with the latest Illuminating Engineering Society of North America (IES) and International Dark Sky Association (IDA) standards to prevent over-lighting of structures and spaces. b. Glare The following glare standard shall generally apply: i. Glare standard. Glare is illumination that is caused by all types of lighting and from high temperature processes such as welding or metallurgical refining. Glare may not directly, or indirectly from reflection, cause illumination on other properties that is in excess of a measurement of 0.5 foot-candles of light; ii. Strobe lights. Strobe lights that are visible from another property are not allowed. c. Building and/or site design shall include public realm pedestrian lighting to supplement streetlights, contribute to the pedestrian scale of the street, and enhance safety. (i) Integrate pedestrian lighting along the length of the street and within public realm areas to facilitate visibility for "eyes on the street." (ii) Light areas to be usable and safe at night and encourage nighttime pedestrian activity. This includes, but is not limited to, curb ramps, crosswalks, bus stops, plazas, paseos, mid-block connections, open spaces, parking lots and structures, seating areas, and pedestrian linkages between these areas. d. Building design shall integrate building-mounted lighting, consistent with the design and character of the structure, to aid in lighting the following areas: 1. The pedestrian way, including areas along primary or side streets. 2. Pedestrian paths, including mid-block connections, from parking lot areas to the building or street. 3. Parking structure entryways and lobbies. 5. Fences, Walls and Screening. Fences, walls and screening for NI zones shall be permitted subject to the following standards: a. Fences, walls, and screening within required setback. Fences enclosing permitted outdoor activities, storage, parking, or for security purposes within the street setback are permitted subject to the following conditions: i. Minimum setback. Minimum setback of 12 inches is required for fences located within the required street setback. ii. Minimum landscaping. The minimum setback area must provide landscaping with vertical vines or tall shrubs between the fence and the minimum sidewalk width. iii. Minimum required visibility. Portions of fences greater than 42 inches in height within the street setback shall be at least 75% open; portions 42 inches in height or lower are permitted to be walls. iv. Fences and/or walls used for required screening shall be a minimum of 6 feet in height. b. Height Limits. The height of Fences and/or walls shall be subject to the limitations specified in Table 41-3. Table 41-3 Fence Maximum Height Regulations1 *See Chapter 21.43 for Fences and Garden Wall Regulations Zones | Notes and Exceptions Code section numbers reference the Long Beach Municipal Code NI-1 (Neo-Industrial Focused) | NI-2 (Flexible Designation: Neo-Industrial + Commercial) A Within required street setback - solid fence/wall | 3 feet | 3 feet | Section 21.43.030 Within required street frontage setback - open fence/wall | 12 feet high wrought iron/metal tubing fence | 8 feet high wrought iron/metal tubing fence | Section 21.43.030 B Abutting residential front yard | 3 feet | 3 feet | Section 21.43.030 C Abutting residential side or rear yard | 10 feet | 8 feet | Section 21.43.030 D Other yard | 12 feet | 10 feet | Section 21.43.030 E Corner cutoff area | 3 feet | 3 feet | Section 21.43.030 Notes: 1) The limitations shall not apply in the following instances: Where a greater height is required by any other City ordinance; or Where a greater height is required by a conditional approval of a permit pursuant to this Title or is required by State or Federal law; or Where a wall return of greater height is allowed; In corner cutoff areas, chain link and wrought iron/metal tubing fences more than three feet (3′) in height are allowed if they do not obstruct visibility. c. Material (i) Materials. Fences and walls must be constructed of wood, vinyl, brick, masonry, textured concrete or aggregate concrete. (ii) Prohibited materials. Prohibited materials for fences and walls include barbed wire and those such as corrugated or sheet metal, tires, car doors, or other discarded materials. (iii) Chain link/wire mesh. A chain link or wire mesh may be used only in combination with plant material of sufficient density to create a year-round opaque screen. Chain link or similar wire fencing is prohibited between the front of a building and a public street but allowed on interior and rear yards. (iv) Security fencing. Electronic theft fences are allowed. d. Maintenance (i) All walls and fences shall be maintained in good condition at all times. e. Alternative Process (i) Alternative heights and materials may be permitted for fences or walls pursuant to the Adjustment Process in Section 22.13.104 of the Zoning Code. (ii) Alternative fence and wall heights and materials may also be approved pursuant to the Adjustment Process in Section 22.13.104 of the Zoning Code if proposed with a new development project. (iii) Alternatives for fence and/or walls must meet the following minimum criteria: A) The fence design shall be open wrought iron or other metal pickets; B) The fence shall allow emergency egress; C) The fence design shall provide visitor, meter reader and emergency personnel access; D) The front yard shall have approved landscaping; E) The applicant shall restore any missing street trees; and F) The fence shall have self-closing, self-locking gates. 6. Trash and Recycling. In addition to Chapter 8.60 Solid Waste, Recycling and Litter Prevention, these provisions prescribe standards for adequate, accessible and convenient locations for the collection and storage of trash and recyclable materials with containers and enclosures which are compatible with surrounding land uses and structures. a. Standards. Adequate receptacles shall be provided to accommodate the trash and recycling generated on a site. All required receptacles shall be developed according to the following standards: i. Minimum Size. Each receptacle area shall have adequate area to contain a size appropriate to the demands of the use and to accommodate separation of materials for trash and recycling. The minimum size of trash and recycling areas shall be as identified in Table 41-4 below. Table 41-4 Minimum Trash and Recycling Material Storage Areas Gross Floor Area Per Development (Square Feet) | Minimum Trash Area Per Development (Square Feet) | Minimum Recycling Area Per Development (Square Feet) | Total Minimum Area Per Development (Square Feet) 0—5,000 | 12 | 12 | 24 5,001—10,000 | 24 | 24 | 48 10,001—25,000 | 48 | 48 | 96 25,001—50,000 | 96 | 96 | 192 50,001—75,000 | 144 | 144 | 288 75,001—100,000 | 192 | 192 | 384 100,001+ | 192 plus 48 square feet for every 25,000 square feet of building area above 100,001 | 192 plus 48 square feet for every 25,000 square feet of building area above 100,001 | 384 plus 96 square feet for every 25,000 square feet of building area above 100,001 ii. Screening. All receptacles shall be enclosed on at least three (3) sides by a solid masonry wall of minimum height five feet, six inches (5'6"). The receptacle shall not be visible above the wall. A visually solid gate shall be provided. iii. Location. All trash and recycling areas must adhere to the following locational standards: A) Shall not be located in required street yards. B) Shall be located and arranged to be accessible to occupants and haulers. iv. Landscaping. All trash and recycling areas if visible from a street shall be further screened with a two foot (2') wide landscape strip. The strip shall be planted with shrubs of minimum five (5) gallon size which grow to a height of four feet (4'), with vines planted to the satisfaction of the Director of Community Development. v. Signage. One sign identifying the material storage area is required for each area and shall be posted on the exterior of the material storage area near the point of access. The maximum sign copy area permitted for each sign shall be one square foot. b. Review procedures. Plans indicating the proposed design, size and location of both new and existing recycling and trash enclosures shall be submitted to the Director of Community Development to be reviewed concurrently during the appropriate review procedure required for the proposed development. For those development projects not requiring planning applications but for which building permits are required, plans indicating the design, size and location of recycling and trash enclosures shall be submitted to the Building Official, to be included with the building permit plan check submittal for the proposed development project.

(ORD-24-0015 § 1(Exh. A), 2024)

Ask a question about Long Beach law

Corpus searches the Long Beach sections it holds and shows the ones that match, with their citations. Free, no sign-in.