Section 17F.070.220 Doors and Openings

A. The requirements of IBC Sections 1014, 1015, 1016, 1017, 1018, 1019, and 1020 apply, except that: 1. an existing, solid, bonded wood core door, one and three-eighths inch thick, or an equivalent, may be kept; and 2. a door or other opening protected on both sides by an approved thermal detection or sprinkler system may open on an exit, so long as the opening does not lead to a special area to be protected, as defined in SMC 17F.080.090. B. Transoms and openings (except doors from corridors to rooms) must be fixed closed and covered with material equivalent to the surrounding separation. C. A door, when open, must not reduce the minimum required width of an exit way more than seven inches.

Date Passed: Monday, June 7, 2010 Effective Date: Thursday, July 1, 2010 ORD C34600 Section 11