For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 7-82 — Specific standards for riverine/shallow flooding zones

Code of Ordinances, City of Batesville, Mississippi (Supp. No. 54: codified through Ordinance No. 2023-08-914, adopted August 15, 2023) · Batesville Code of Ordinances § 7-82

Corpus is an independent public-information project, not the official City of Batesville website. Stable reference: corpuslaw.us/code/7cabfc9d-bffa-4aa7-845c-5e6c4a831fa3

Sec. 7-82. - Specific standards for riverine/shallow flooding zones.

In all areas of special flood hazard designated on the community's FIRM, where base flood elevation data have been provided, as set forth in article III, section 7-37, the following provisions, in addition to the standards of article V, section 7-81, are required: (1) Residential construction. New construction and substantial improvement of any residential building (including manufactured home) shall have the lowest floor, including basement, elevated to or no lower than eighteen (18) inches above the base flood elevation. Should solid foundation perimeter walls be used to elevate a structure, flood openings sufficient to automatically equalize hydrostatic flood forces on exterior walls of enclosures that are subject to flooding, shall be provided in accordance with standards of article V, section 7-82(4). a. All new construction and substantial improvements of residential structures within AO zone shall have the lowest floor (including basement) elevated to or above the highest adjacent grade at least as high as one (1) foot above the depth number specified in feet on the FIRM (at least three (3) feet if no depth number is specified). (2) Nonresidential construction. New construction and substantial improvement of any commercial, industrial, or nonresidential building (including manufactured building) shall have the lowest floor, including basement, elevated to eighteen (18) inches above the base flood elevation. Buildings located in all A zones may, together with attendant utility and sanitary facilities, be floodproofed in lieu of being elevated provided that all areas of the building below the base flood elevation eighteen (18) inches plus a minimum of one (1) foot of freeboard are water tight with walls substantially impermeable to the passage of water, and use structural components having the capability of resisting hydrostatic and hydrodynamic loads and the effect of buoyancy. Dry floodproofing is allowed only where flood velocities are less than or equal to five (5) feet per second. A registered professional engineer or architect shall certify that the standards of this subsection are satisfied. A flood emergency operation plan and an inspection and maintenance plan must be provided by the design professional for the building. Such certification shall be provided to the floodplain administrator. a. All new construction and substantial improvements of nonresidential structures within AO zone shall: 1. Have the lowest floor (including basement) elevated above the highest adjacent grade at least one (1) foot higher than the depth number specified in feet on the FIRM (at least three (3) feet if no depth number is specified), or 2. Together with attendant utility and sanitary facilities be completely floodproofed to that level to meet the floodproofing standard specified in article V, section 7-82(2). (3) In special flood hazard areas with base flood elevations (AE zones) but without floodways, no encroachments, including fill material or structures, shall be permitted unless certification by a registered professional engineer is provided demonstrating that the cumulative effect of the proposed development, when combined with all other existing and anticipated development, will not increase the water surface elevation of the base flood more than one (1) foot at any point within the community. The engineering certification must be supported by technical data that conforms to standard hydraulic engineering principles. a. Within AH and AO zones on the FIRM, adequate drainage paths around structures on slopes shall be provided to guide floodwaters around and away from proposed structures. (4) Enclosures. New construction and substantial improvements that include fully enclosed areas formed by foundation and other exterior walls below the lowest floor shall be designed to preclude finished living space and designed to allow for the entry and exit of floodwaters to automatically equalize hydrostatic flood forces on exterior walls. Enclosed areas, including crawl spaces, shall be used solely for parking of vehicles, building access, and storage. a. Designs for complying with this requirement must either be certified by a professional engineer or architect or meet or exceed the following criteria: 1. Provide a minimum of two (2) openings, on different sides of each enclosed area; if a structure has more than one (1) enclosed area below the base flood elevation, each shall have openings on exterior walls; 2. The total net area of all openings shall be at least one (1) square inch for each square foot of enclosed area, or the openings shall be designed and the construction documents shall include a statement that the design and installation will provide for equalization of hydrostatic flood forces on exterior walls by allowing for the automatic entry and exit of floodwaters; 3. The bottom of all openings shall be no higher than one (1) foot above interior grade (which must be equal to in elevation or higher than the exterior grade); 4. Openings may be equipped with screens, louvers, valves or other coverings or devices provided they permit the automatic flow of floodwaters in both directions and automatically equalize hydrostatic flood loads on exterior walls, and; b. Access to the enclosed area shall be minimum necessary to allow for parking of vehicles (garage door) or limited storage of maintenance equipment used in connection with the premises (standard exterior door) or entry to the living area (stairway or elevator); and, c. The interior portion of such enclosed area shall not be finished or partitioned into separate rooms. (5) Detached storage buildings, sheds, or other like accessory improvements, excluding detached garages, carports, and boat houses, shall solely be used for parking of vehicles and storage. Such storage space shall not be used for human habitation and shall be limited to storage of items that can withstand exposure to the elements and have low flood damage potential. The storage space shall be constructed of flood resistant or breakaway materials, and equipment and service utilities, such as electrical outlets, shall be limited to essential lighting and other incidental uses, and must be elevated or floodproofed. Flood openings in accordance with the standards of article V, section 7-82(4) shall also be required. These accessory structures shall be constructed and placed on the building site so as to offer the minimum resistance to the flow of floodwaters. Accessory improvements and other appurtenant structures shall be firmly anchored to prevent flotation that may result in damage to other structures. (6) Standards for manufactured homes and recreational vehicles. a. All manufactured homes placed, or substantially improved, on individual lots or parcels, in existing manufactured home parks or subdivisions, in expansions to existing manufactured home parks or subdivisions, in new manufactured home parks or subdivisions or in substantially improved manufactured home parks or subdivisions, must meet all the requirements for new construction, including elevation and anchoring and the flood openings requirements of article V, section 7-82(4). Manufactured homes must be: 1. Elevated on a permanent foundation to have its lowest floor elevated to no lower than eighteen (18) inches above the base flood elevation, and; 2. Securely anchored to an adequately anchored foundation system to resist flotation, collapse, and lateral movement, and; 3. Require that all manufactured homes be placed or installed using methods and practices which minimize flood damage. Manufactured homes must be elevated and anchored to resist flotation, collapse, or lateral movement. Dry stacked blocks (stacked without the use of mortar or cement to bond them together) are not allowed within the special flood hazard area. b. All recreational vehicles placed on sites must either: 1. Be on site for fewer than one hundred eighty (180) consecutive days and shall leave the site and obtain a new permit before returning to the same site, and; 2. Be fully licensed and ready for highway use, or; 3. Must meet all the requirements for new construction, including anchoring and elevation requirements of this article V, section 7-82(7)a. above. A recreational vehicle is ready for highway use if it is licensed and insured in accordance with the State of Mississippi motor vehicle regulations, is on its wheels or jacking system, is attached to the site only by quick disconnect type utilities and security devices and has no permanently attached additions. (7) Floodways. Located within areas of special flood hazard adopted by reference in article III, section 7-37, are areas designated as floodways. Since the floodway is an extremely hazardous area due to the velocity of flood waters which carry debris, potential projectiles and has erosion potential, the following provisions shall apply: a. Prohibit encroachments, including fill, new construction, substantial improvements, and other developments unless certification (with supporting technical data) by a registered professional engineer is provided demonstrating that encroachments shall not result in any increase in flood levels during occurrence of the base flood discharge; b. If article V, section 7-82(8)a. above is satisfied, all new construction and substantial improvements shall comply with all applicable flood damage prevention standards of article V. c. Prohibit the placement of manufactured homes (mobile homes), except in an existing manufactured home (mobile homes) park or subdivision. A replacement manufactured home may be placed on a lot in an existing manufactured home park or subdivision provided the anchoring standards of article V, section 7-81(2), and the standards of Article V, section 7-82(1) through (3) and the encroachment standards of this article V, section 7-82(8)a., are met.

(Ord. No. 2021-01-884, art. 5, B., 1-21-21)

Ask a question about Batesville law

Corpus searches the Batesville sections it holds and shows the ones that match, with their citations. Free, no sign-in.