§ 16-3.24.110 — Waste/recycling material enclosures
Victorville, California, Municipal Code (Supp. No. 57: codified through Ordinance No. 2466, passed April 7, 2026) · Victorville Municipal Code § 16-3.24.110
Corpus is an independent public-information project, not the official City of Victorville website. Stable reference: corpuslaw.us/code/7cd490fa-e3b3-414d-83c1-6bea2f110281
16-3.24.110: - Waste/recycling material enclosures.
(a) Applicability. The requirements of this section shall apply to all buildings or development permits for: (1) New commercial development projects. (2) New multi-family residential development projects that will utilize shared waste and recycling enclosures. (3) Existing commercial development projects, including but not limited to tenant improvements, that require a planning entitlement (such as a site plan review or conditional use permit) or as otherwise noted within this section. (b) Definitions. The terms used in this Chapter have the meanings set forth below: "Collection" means the removal and transportation of solid waste, recycling and organics by the collector from the place of delivery to a disposal facility approved under the collector's agreement with the city or by a nonexclusive franchise agreement. "Collector" means that person or business having an exclusive franchise agreement with the city granting to him/her or it the exclusive privilege of collecting or causing to be collected or transported for a fee any solid waste within the city or any portion thereof. "Commercial development" means the construction of or existing sites and buildings consisting of retail, professional, wholesale, or industrial facilities. "Compactor" means any roll-off container or bin which has a compaction mechanism, whether stationary or mobile. "Discharge" means any addition of any pollutant that has potential to enter navigable waters from any point source. "Food service establishments" include restaurants, markets, bakeries, grocery stores and all other establishments that prepare and/or serve fresh food on the premises. "Multi-family residential development" includes the construction of or existing sites and buildings consisting of multiple dwelling units such as apartments, condominiums, duplexes, triplexes, mobile home parks, etc., and excluding single-family dwellings that include an accessory dwelling unit. "National Pollutant Discharge Elimination System (NPDES)" means a national program under Section 402 of the Clean Water Act for regulation of discharges of pollutants from point sources to waters of the United States. Discharges are illegal unless authorized by an NPDES permit. "Organics" means all types of plant debris including grass and weed clippings, shrub and tree pruning, branches (less than four (4) feet in length and four (4) inches in diameter), leaves, plants, flowers, food scraps and food-soiled paper products. "Owner" means the owner or owners of real property having fee title to the property as identified in the most recent equalized assessment roll of the San Bernardino County Assessor. "Park" means and includes all grounds, trails, buildings, improvements and areas dedicated for use by property residents and their quests for park, recreation or open space purposes, and any part, portion or area thereof, whether developed or undeveloped or over which the property owner has acquired right of use for such purposes. "Pollutant" means dredged soil, solid waste, incinerator residue, sewage, sewage sludge, munitions, chemical wastes, biological materials, radioactive materials, heat, wrecked or discarded equipment, rock, sand, dirt and industrial, municipal and agricultural waste discharge into water. "Public Litter Container" means a permanent or semi-permanent (e.g. secured in placed and not easily removed) solid waste, recycling, and/or organics waste collection container(s) utilized for intermediary refuse collection prior to transport to the waste enclosure by the property owner or their designee. "Recycling" consists of any clean, dry paper, cardboard, plastic and glass (bottles, jars and jugs only), and metal cans (tin and aluminum) placed in a single container. Cardboard is accepted in recycling bins and carts; however, cardboard-only dumpsters are also available. "Roll-off container" means a metal container that is normally loaded onto a motor vehicle and transported to an appropriate facility. "Solid waste" means all putrescible and nonputrescible solid waste (garbage), including paper, ashes, industrial or commercial wastes, demolition and construction wastes, discarded home and industrial appliances, animal solid and semi-solid wastes other than fecal matter, vegetable wastes, and other discarded solid and semi-solid wastes, but does not include hazardous waste, as herein defined, sewage, or abandoned automobiles. "Stormwater" means rainwater runoff, snow melt runoff, surface runoff and drainage. "Tenant" means any person or persons other than the owner occupying or in possession of the residence or commercial space. "Waste enclosure" means a structure intended to serve collection and storage needs for solid waste, recycling, and organics waste. (c) General construction, design, and maintenance standards. (1) General waste enclosure requirements. The location, design and construction of waste enclosures for the set out and collection of garbage, recycling, organics or other discarded materials shall conform to all applicable regulations set out in this section and to all other provisions of the Victorville Municipal Code. A commercial or multi-family residential development may be required to have multiple waste enclosures to meet the required amount of capacity. The Zoning Administrator shall review the design of all waste enclosures. All new waste enclosures are subject to a building permit and shall be shown on the respective site plan. (2) Commercial development waste enclosure standards. All commercial uses within the city shall at a minimum provide adequate space for separate garbage bins, recycling bins, and organics bins within a waste enclosure. If a food service establishment will generate fat, oil, grease, or associated by-products (e.g. lard and tallow), adequate space for those containers is required within the waste enclosure if the fat, oil, grease, or associated by-product containers are not collected and stored inside the commercial building within a designated and established area. The types and sizes of bins shall be based on the volume of tonnage generated by the planned commercial activity, and with the aim of reducing, as much as possible, the number of service trips per week by the collector. (3) Waste enclosure design standards: Enclosure Element | Requirements Location | Shall not be located along frontage roadways, in front of fire hydrants, behind parking spaces, or within 5' of combustible building wall, opening, or combustible roof eave line User Access | • Multifamily properties shall observe California Building Code and California Code of Regulations Title 24 part 2 requirements regarding accessibility for persons with disabilities • Shall provide pedestrian entrance with outward opening door • An accessible path of travel shall be provided from the main building to the pedestrian entrance door Service Provider Access | • Enclosure shall be directly accessible to service provider during normal collection days and hours • Provide a turnaround or separate exit that allows the truck to move forward rather than backwards • Minimum outer turning radius must be at least 42' • Minimum inside turning radius must be at least 28' Standard Enclosure Floor Area | Determined by the number of bins (refuse collection containers) required plus 6" protective concrete edge buffer Bin Spacing | • Minimum 1' between the wall and container • Minimum 1'6" between 2 containers • Minimum 3' wide pathway along the front or rear side of the enclosure Protective Buffer on Interior Enclosure Walls | Minimum 6" concrete curbs Enclosure Wall Height | Minimum 6' Maximum Openings Between Wall/Gates and Ceiling | Maximum 4", preferably the opening between the wall and ceiling is secured with wrought iron fencing with no openings greater than 4" Ceiling Height | Minimum 8' Height Clearance in front of Enclosure | Minimum 26' of height clearance is required within a 50'×20' area for safe bin serviceability Driveway Access | The minimum clearance along the entire route to the enclosure: Horizontal - 12 feet; Vertical - 15 feet Driveway Weight Handling Requirements | 62,000 lbs. Apron Elevation | • Apron surface shall be the same elevation as the enclosure pad threshold and the surrounding surfaces • Maximum 2% slope. Apron Size | The area between the enclosure and the service pick-up area shall be a paved concrete area, minimum 4" in depth, and shall span the width of the enclosure. Pad Interior Elevation | • Pad surface elevation shall equal that of the apron threshold • A slope of 1—1.5% toward the center of the enclosure • For food service establishments, a sanitary sewer drain shall be installed flush with the enclosure pad Enclosure and Apron Pad Weight Handling Requirements | 20,000 lbs. of direct force Enclosure Gates | • Double gates (e.g. 2 free hanging gates with side posts and no center post) with a maximum length of 12' per gate panel • Single set of double gates required for openings of 24' and under • Shall have a mechanism to secure doors in both an open and closed position, including a cane bolt with a sleeve double the size of the bolt. There must be accompanying drilled holes in the enclosure pad and outside the pad to allow for cane bolts to drop at least 4" into the ground. Cane bolt holes must be placed in two locations to secure the gate when closed and when opened. • Shall be lockable using a standard padlock or keypad lock • All gates are to be solid non-transparent metal construction Pedestrian Gate | • Shall be solid non-transparent metal construction • Shall have a minimum width of 3' and height of 6'8" • Shall connect with the accessible pathway to the building and with the interior pathway along the front or rear side of the enclosure • Shall be lockable using a standard padlock Enclosure Opening | Minimum of 12' Roof | • Minimum 8' high at its lowest point • Shall extend over any side or the rear of enclosure by at least 6" Material | • Design of enclosure shall incorporate the same materials and style as the primary building • The walls of enclosure shall be masonry construction • Graffiti-resistant coating should be used on exterior walls • Roofs shall be painted with rust-inhibitive paint Identification | Commercial or multi-family residential development providing 3 or more waste enclosures shall provide numerical identification as follows: i. Numbers shall be installed in sequential order beginning with the waste enclosure closest to the site entrance; ii. Numbers shall be no less than twelve inches in height with a corresponding width; iii. Number and background colors must be of contrasting shades; and iv. Numbers must be visible and identifiable from the abutting driveway access. Lighting | Minimum 1 foot-candle with motion sensor in area around and inside the enclosure Landscaping | 5' landscape strip on non-gated walls if visible from roadways or other public spaces (4) Waste enclosure maintenance. Enclosures and ground surface areas must remain functional as designed and free of debris, accumulated grime, fat, oil or grease and must be pressure washed and cleaned periodically with wash water collected and discharged to the sanitary sewer only. (d) Multi-family residential development requirements. (1) Multi-family residential development waste enclosures in the City of Victorville are required to contain space for separate collection of garbage, recycling and organics. (2) Shared service within a multi-family residential development shall include a minimum of 50 gallons of service for every 3 residents. Required service shall provide space for 40% as trash, 40% as recycling, and 20% as organics (excluding any plant debris from facility maintenance). Adequate enclosure space shall be provided to store estimated solid waste generation. Estimated occupancy shall be based on the number of bedrooms with an assumed 2 people per bedroom. (3) Waste enclosures for collection of garbage, recycling and organics provided for multi-family residential development shall observe the requirements of the California Building Code and the requirements of California Code of Regulations Title 24, regarding accessibility to solid waste and recycling collection containers for persons with disabilities. (e) Compactors. (1) Outdoor compactors are generally not permitted unless preapproved by the Planning Commission as part of a Site Plan application review. Inclusion of a compactor shall not supplant the requirements that a site provide adequate enclosure space for recycling and organics collection. (2) Compactors may require additional space and electrical connections, as well as separate building permits. (3) Compactors are required to be screened from public view, covered, and shall include plumbing directed to the sanitary sewer system to capture possible leaks and spills. (4) Adequate room for service access, including back up and turning area, shall be provided on-site and shall not require use of the public right-of-way. (f) Roll-off boxes. Unless reviewed and approved in conjunction with a Site Plan entitlement that includes access in accordance with the California Building Code, screening via masonry wall and landscaping, solid metal access gates, and stormwater pollution prevention measures, roll-off boxes are permitted only as a temporary use. The temporary use of roll-off boxes is allowable during construction in conjunction with an active building permit or as approved by a Temporary Use Permit for a period not to exceed three months per calendar year, in connection with a principal use on the property, pursuant to Section 16-3.07.050 of the Municipal Code. (g) Permits. All necessary entitlements and/or building permits, as determined by the Zoning Administrator and City Building Official, shall be obtained prior to the construction of any enclosures within the City of Victorville. (h) Exceptions. The Planning Commission shall have the authority to grant exceptions to the requirements of this section. The Planning Commission shall review any exception request as part of a Site Plan application review and shall only approve exceptions in accordance with Section 16-3.01.030 of the Victorville Municipal Code. (i) Stormwater pollution prevention. (1) All properties shall comply with the Federal Clean Water Act. (2) Waste enclosures within the city that are subject to the standards in this Chapter shall have a roof to comply with the City of Victorville's National Pollution Discharge Elimination System (NPDES) stormwater permit. (3) Ongoing Waste Enclosure Use and Maintenance. At a minimum, the following best management practices shall be adhered to: i. The enclosure shall only be used for storage of garbage, recycling, cardboard, organics and used cooking oil/grease containers. Storage of hazardous waste or any other items inside the enclosure is strictly prohibited. ii. Storage of garbage, recycling, cardboard only, or organics containers outside of the enclosure is strictly prohibited. All containers shall be stored inside of the enclosure. Exceptions to this requirement may be approved by the Zoning Administrator due to lack of enclosure or lack of enclosure space. iii. All solid waste and used cooking oil/grease shall always be contained within appropriate water-tight, covered containers including secondary containment. A supply of spill response materials designed to absorb leaking fluids and/or cooking oil/grease spills shall be kept near the enclosure. iv. Overfilling garbage, recycling and/or organics containers is prohibited. Solid waste shall not protrude above the top rim of the container and shall allow for the lid(s) to close fully. Establishments that have more than three (3) instances of overflowing containers within six (6) months will be required to increase their service level(s). v. Solid waste enclosures shall be maintained in good working condition and in the condition that they were approved. Maintenance and cleaning of the solid waste enclosure is the day-to-day responsibility of the occupant or owner of the premises. vi. Washing out the solid waste enclosure to the storm drain system is prohibited. Wash water shall be collected and discharged to the sanitary sewer only. (j) Non-conforming sites with substandard or no on-site waste enclosure. (1) Existing development. If an existing development lacks a waste enclosure or includes a substandard waste enclosure, the development may be required to install a waste enclosure that meets the requirements of this Chapter. The Zoning Administrator shall determine the requirement for a waste enclosure based upon any of the following: i. Section 16-3.05.060 of the Victorville Municipal Code, titled "Nonconforming sites"; ii. Compliance with California Green Building Code standards; or iii. Recommendation by the City Manager or their designee, the City Code Enforcement Official, or the City Director of Public Works with evidence of the development's missing waste enclosure causing a public nuisance or being injurious to the public health, safety and welfare. (2) Code compliance. Where waste is not being fully contained and secured within a dumpster where no or substandard on-site waste enclosure exists, the Code Enforcement Official shall: i. Issue a Notice of Violation to the property owner and the business owner. ii. Upon the issuance of the third Notice of Violation within a 12-month period, the Code Enforcement Official may require the replacement of the dumpster with a tamper proof dumpster. iii. After four documented instances of waste not being fully contained and secured within a dumpster where no on-site waste enclosure exists, and after utilizing a tamper proof dumpster, the Code Enforcement Official shall require the installation of a fully conforming waste enclosure that complies with this Section for any multifamily or commercial property. Such instances may include but are not limited to overflowing containers, scattered waste located near a container or other litter-related or theft incidences causing a disturbance to the health, comfort or welfare of the community. (3) New dumpsters. Additional dumpsters shall not be added to non-conforming sites, unless located within a waste enclosure that meets the requirements of this section. New or modified waste enclosures shall require a building permit and a site plan entitlement based upon the scope of the proposal, as determined by the Zoning Administrator and City Building Official. (k) Public litter containers for commercial and multifamily properties. It shall be the responsibility of the property owner to install, maintain, and empty the public litter containers for all new developments. (1) Location of Public Litter Containers. i. Install public litter containers within ten (10) feet of any food-generating or food-selling store planned for the property. ii. Include containers along internal, on-site walkways at intervals of three hundred (300) to three hundred fifty (350) feet. iii. Locate containers at pedestrian entrance(s) and exit(s) of property. iv. The final location of public litter containers are subject to Zoning Administrator review and shall be placed based on existing or anticipated pedestrian traffic specific to the site. (2) Properties that Involve Outdoor Eating Area. i. Include three (3) compartment discard waste cans that are central and visible to the eating area. ii. Label the three (3) compartment discard waste cans with clear signage describing organics. recycling and garbage. (3) Design of Public Litter Containers. i. When selecting public litter containers, they should be considered as a design element and the design should reflect aesthetic as well as functional concerns. ii. Public litter containers should be selected from the same or a similar design family as other site furnishings (such as benches, bollards, bike racks, etc.) and should be finished or painted to complement other site furnishings. iii. Public litter container construction should use durable, high quality materials, such as galvanized or stainless steel. iv. Materials should be painted to reflect colors similar to nearby elements. Material and paint selection should be graffiti resistant. v. Public litter containers should include recycling containers and should be able to open from the side to allow easy access for removal of waste. (4) Maintenance of Public Litter Containers. i. It is the responsibility of the property manager or owner to empty the contents of the public litter containers at least once a week or more frequently as use dictates to prevent overflow of any litter containers. ii. Public litter containers should be kept clean and free of graffiti. (5) The Code Enforcement Official, at his or her discretion, may also require installation of public litter containers that comply with this section for any multi-family or commercial property having repeated litter issues. Such issues may include but are not limited to overflowing garbage, recycling and organics containers, litter on the ground in common areas, or other litter-related incidences causing a disturbance to the health, comfort or welfare of the community.
(Ord. No. 2415, § 3, 3-2-21)
Ask a question about Victorville law
Corpus searches the Victorville sections it holds and shows the ones that match, with their citations. Free, no sign-in.