Springfield, Ill., City Code § 94.80 Requirements for basement dwelling units in existence prior to 1989.
§ 94.80. - Requirements for basement dwelling units in existence prior to 1989.
Basement dwelling units in existence prior to 1989 shall be allowed if they comply with one of the following requirements:
(1) Existing basement dwelling units that have one approved means of egress and have windows in the sleeping room meeting the requirements of section 1030 of the 2018 International Fire Code and any future amendments thereto, and have one-hour rated construction between each dwelling unit both vertically and horizontally;
(2) Existing basement dwelling units meeting all the requirements of subsection (1) except for the sill height requirement of not more than 44 inches from the floor, provided that a permanent platform is built under the bedroom window which platform:
a. Is four inches greater in width on each side of the window opening;
b. Extends 18 inches from the wall;
(3) Is constructed in accordance with the 2018 International Building Code and any future amendments thereto; and
(4) Has steps meeting the 2018 International Building Code and any future amendments thereto, if the platform is over eight inches in height.
(Ord. No. 190-04-06, § 1(Exh. A), 4-4-06; Ord. No. 489-07-07, § 1(Exh. A), 7-17-07; Ord. No. 056-02-23, § 1(Exh. A), 2-21-23)