550.2040. - Development standards for all permitted skyways.
New skyways shall comply with the following standards and all other applicable regulations of this zoning ordinance:
(1) All skyways.
a. At least eighty (80) percent of the exterior sidewalls of the skyway shall be glazing that allows views into and out of the skyway, except as otherwise permitted for temporary on-premises signs, temporary art, or permanent art on skyway bridges under subsection (3). Glazing shall have clear or lightly tinted glass with a visible light transmittance ratio of six-tenths (0.6) or higher.
b. At least eighty-five (85) percent of the glazing area of the exterior sidewalls of a skyway shall meet the bird-safe glazing definition.
(2) Skyways that cross a public street or a public alley.
a. Skyways will only be considered for uses in downtown zoning districts; or hospital, college, or university uses outside of downtown zoning districts, subject to the standards of this article.
b. Skyways shall only be allowed on the second floor of a building.
c. Skyways shall run perpendicular to the public street or public alley that they cross.
d. Skyways shall be designed to be horizontally level with the street. Changes in grade shall be accommodated so that the skyway appears level from the exterior.
e. Skyways shall not be allowed within fifteen (15) feet of a street intersection. Skyways are encouraged to cross public streets and alleys in the middle portion of the block.
f. Skyways shall be a single story.
g. The bottom of skyways shall be a minimum of sixteen (16) feet six (6) inches above the public street or public alley.
h. Skyways shall comply with the requirements of subsections (1) and (3) of this section as applicable.
(3) Skyways within the downtown skyway system.
a. Skyway width shall be carefully considered in relation to each skyway's relative location within the system and the projected intensity of use for that skyway and shall be subject to the following conditions:
1. Skyways and connecting corridors shall have a minimum interior clear width of twelve (12) feet between handrails.
2. Skyways and connecting corridors within the core of the downtown skyway system are encouraged to have a minimum interior clear width of eighteen (18) feet.
3. The exterior width of skyways shall be no wider than thirty (30) feet.
b. Access to skyways shall be facilitated between street and skyway levels. Such access shall be subject to the following conditions:
1. A public entrance that is clearly defined and emphasized through the use of architectural features, such as an awning, glazing, or other details, shall provide street access to the skyway.
2. Exterior signage shall be provided at the street-level entrance noting the skyway entrance location.
3. Elevators, stairs and escalators linking the street and skyway level shall be clearly identified with directional signage. For new buildings, elevators, stairs and escalators linking the street and skyway level shall also be conveniently located.
4. Interior signage shall be provided at the skyway level, noting access to public streets.
c. Skyways shall remain open to the public Monday through Friday, from 6:30 a.m. to 10:00 p.m., Saturday, from 9:30 a.m. to 8:00 p.m., and Sunday, from 12:00 p.m. to 6:00 p.m. Property owners are encouraged to keep their skyways, connecting corridors, and vertical circulation elements open beyond standard hours of operation.
d. Skyway bridges shall be used principally for pedestrian movement. Skyway bridges may be utilized for permanent and temporary uses as listed below, subject to the city engineer's authority to deny or remove items to protect the public health, safety, and welfare, and prevent interference with the safety and convenience of ordinary travel over the right-of-way, in accordance with Chapters 95, 427, 429, and 430 of this Code, and the following standards:
1. Permanent retailing, seating, vending, and display shall be confined to spaces off the skyway bridge.
2. Temporary on-premises signs, temporary art, or permanent art shall be permitted on the exterior or interior of skyway bridges as intended to be read from the public right-of-way, provided such temporary on-premises signs, temporary art, or permanent art shall comply with the following:
i. Temporary on-premises signs, temporary art, or permanent art shall allow views into and out of the skyway on at least twenty-five (25) percent of the exterior sidewalls.
ii. Temporary on-premises signs, temporary art, or permanent art shall not extend below the physical exterior of the skyway bridge, except as reviewed and approved by the city engineer, but in no case shall extend below sixteen (16) feet six (6) inches above the public street or public alley.
iii. Building wrap signs shall be permitted.
3. Temporary uses within skyway bridges shall comply with Section 525.630 and Article IV, Temporary Uses, in Chapter 545 of this Code, and shall not block pedestrian movement.
e. Skyways shall comply with the requirements of subsections (1) and (2) of this section as applicable.
(Ord. No. 2025-054, § 2, 11-20-2025)