Sec. 49-1014. - Receiving fixtures and openings.
The following provisions shall be observed regarding plumbing fixtures and openings approved for receiving the discharge of indirect waste (floor drains, floor sinks, mop sinks, service sinks or a stand pipe connected to a p-trap) see Table 49-1014 below for allowable flow rates: (a) The fixture or opening shall be of a shape and capacity to prevent splashing or flooding and shall be located where readily accessible for inspection and cleaning. (b) When used as a receiving fixture, a floor drain rim shall be flush with the floor and the strainer recessed one inch below the finished floor. (c) In rooms where human food or drink are stored, processed or prepared, receiving fixtures shall be floor sinks that can be easily cleaned and inspected. Hub drains are not permitted in these areas. (d) An indirect waste shall not discharge into fixtures used for culinary purposes. (e) Fixtures, appliances, devices or appurtenances shall be piped independently to the receiving fixture. (Exception: air conditioning/air distribution equipment units) (f) The receiving fixture or opening shall be located in the same room as the fixtures, appliances, devices or apparatuses served. Table 49-1014 Receiving Fixture Type | Drain Connection Diameter (inches) | Maximum Allowable Acceptance Flow Rate Floor drain with top strainer. (1) | 2 | 13.6 3 | 30.6 4 | 54.4 6 | 122.3 8 | 217.5 Floor drain/floor sink without top strainer with standard depth sump. (1) | 2 | 19.2 3 | 43.2 4 | 76.9 6 | 173.0 8 | 307.5 Floor drain/floor sink without top strainer with minimum four-inch deep sump. (1) | 2 | 23.5 3 | 53.0 4 | 94.2 6 | 211.9 8 | 376.7 Standpipe with P-trap and minimum six-inch riser. | 2 | 23.5 3 | 53.0 4 | 94.2 6 | 211.9 8 | 376.7 Mop sink with drop front. | 2 | 25.0 (2) 3 | 59.0 (2) Mop sink without drop front. | 2 | 40.8 (2) 3 | 94.5 (2) (1) For trench drains with multiple connections, flow rate listed is for each connection. Example: standard trench drain with top strainer and two 4" diameter drain connections has a maximum allowable acceptance flow rate of 108.8 (54.4+54.4) GPM. (2) Flow rate has been reduced by 2.2 GPM to account for faucet flow rate. _____
(Ord. No. 40524, § 1, 10-20-15)
Ask a question about Omaha law
Corpus searches the Omaha sections it holds and shows the ones that match, with their citations. Free, no sign-in.