§ 5-76 — General sprinkler requirements

Code of Ordinances, City of Southaven, Mississippi (Supp. No. 70: codified through Resolution of June 2, 2026) · Southaven Code of Ordinances § 5-76

Corpus is an independent public-information project, not the official City of Southaven website. Stable reference: corpuslaw.us/code/804d211c-16bf-4196-b332-264b45bf4468

Sec. 5-76. - General sprinkler requirements.

(a) An approved automatic fire protection sprinkler system, designed and installed to National Fire Protection Codes and Standards (NFPA), shall be provided for the following, new constructed buildings, major renovated buildings as defined in subsection (c), and existing structures due to a change in occupancy classification or requirement to comply with the city's nonconforming ordinance. (1) Places of assembly: All buildings as required by International Building Code and International Fire Code (as adopted) and assembly occupancies eight thousand (8,000) square feet or more of gross area under roof. 2 (2) Educational: All buildings, this includes residential occupancies used as day care for children. [4] (3) Institutional occupancies: All buildings; this includes any day care for children or adults that has more than five (5) patients/clients. (4) Residential: Single- and multifamily buildings as follows: a. Hotel/motel (NFPA 13). b. Lodging and rooming houses, board and care facilities, multifamily dwellings and townhouses shall comply with Section 903.3.1.2 of the International Fire Code (as adopted), and sprinklers shall be in accordance with NFPA Standards 13D and 13R, up to four (4) floors. Otherwise, such uses shall comply with Section 903.3.1.1 of the International Fire Code. c. One and two-family residential dwellings six thousand five hundred (6,500) square feet or more gross area under roof 2 shall comply with NPFA 13D. One and two-family residential dwellings under six thousand five hundred (6,500) square feet of gross area under roof 2 and not used as a child day care are exempt. These structures shall comply with the International Residential Building Code (as adopted). (5) Mercantile: All buildings eight thousand (8,000) square feet or more gross area under roof. 2 (6) Business: All buildings eight thousand (8,000) square feet or more gross area under roof. 2 (7) Industrial: All buildings eight thousand (8,000) square feet or more gross area under roof. 2 (8) Storage: All buildings eight thousand (8,000) square feet or more gross area under roof. 2 (9) Mixed occupancies: All buildings eight thousand (8,000) square feet or more gross area under roof. 2 (10) H-1, H-2 and H-3, H-4 hazardous occupancies: All buildings regardless of size shall be sprinklered. (b) For the purpose of this section, occupancies shall be classified in accordance with the International Building Code, as adopted by the city. Any change of occupancy or change of hazard or hazard class of hazard will require compliance with this code. (c) For the purpose of this section, major renovation shall be defined as construction to the building that is greater than fifty (50) percent of the estimated cost of reconstructing the entire structure or considered to be major by the building official and the appropriate fire official. (d) Any addition to an existing building which brings the gross area under roof [5] above the applicable square footage listed in the above articles shall cause the entire building to meet the requirement of that section. (e) Where these requirements conflict with the city building code, fire code, state, federal standards or local requirements, the most stringent shall apply. (f) Automatic extinguishing systems and appurtenances shall be designed, installed, tested, inspected and maintained in accordance with NFPA as referenced in the International Building Code (as adopted) and the International Fire Code (as adopted). (g) Any automatic fire protection sprinkler system provided as a requirement of this section or any other code requirement shall be adequately supervised as follows: (1) The extinguishing system shall be electrically monitored by an approved central station facility meeting the requirements of NFPA 71. (2) Where building fire alarms facilities are provided, actuation of the fire sprinkler system will cause the building alarm to sound in accordance with NFPA 72. All Fire Alarm Control Panels (FACP) and the components of which they consist, including any ancillary components that provide support to the system such as any type of initiating device, heat sensor, smoke detector, horn strobe etc., shall be listed by Underwriters Laboratories (UL), and/or Factory Mutual (FM), or other certifying laboratory accepted by the fire marshal. Combination fire/security or coded systems will not be allowed. (3) Runner service; a runner or technician as defined by NFPA 72, must be dispatched to the protected premises so as to arrive within 1 hour after receipt of a signal, when required to respond. (h) For the purpose of this section, only approved four-hour rated fire walls separate buildings, in occupancies specified in the above section. [6] A fire wall is defined as a four-hour, fire-resistant wall which restricts the spread of fire and extends continuously from the foundation to or through the roof, with sufficient structural stability under fire conditions to allow collapse of construction on either side without collapse of the wall. In existing buildings when it is not practical to accomplish construction of this type fire wall, approved alternate methods of construction meeting the intent of the code may be considered and approved by the fire official. (i) Where automatic sprinkler protection is determined to increase the hazard to an area of the property or occupants to be protected, other automatic extinguishing systems appropriate for the hazard shall be provided. (j) Owners or occupants that wish to appeal the enforcement of this chapter by the fire prevention division shall be able to file such appeal under the provisions as provided for in section 5-31 of this title. (k) In all multi-tenant buildings with sprinkler systems, where a fire alarm system is required by the Code, a minimum of one (1) notification device must be provided in each tenant space. (l) In all multi-tenant buildings, an isolation valve and flow switch must be provided so that firefighters might identify a water flow condition in a timely manner during an emergency event. Test connections must be provided to verify operation of initiating devices. (m) A contractor licensed to install an automatic extinguishing system must install all piping within a building and to a point five (5) feet outside the building. Only contractors approved to install public utilities and/or fire protection sprinkler systems/ fire main loop shall install piping from a point five (5) feet outside a building to the water provider's connection. Maintenance of piping and fire hydrants shall be performed by the contractor in compliance with the regulations of the Mississippi State Board of Contractors, for the duration of the building project. Loop systems for yard piping are required for increased reliability and improved hydraulics. Loop systems should be sectionalized by placing valves at branches and at strategic locations to minimize the extent of impairments.

(Ord. No. 84, 9-1-98; Amd. of 9-4-07, § 6; Res. of 6-16-15; Res. of 9-15-20(1), eff. 1-1-21)

Ask a question about Southaven law

Corpus searches the Southaven sections it holds and shows the ones that match, with their citations. Free, no sign-in.