Sec. 16-17. - Amendments to the 2024 International Fire Code.
The 2024 International Fire Code is amended in the following respect:
Section 101.1 is hereby amended to read as follows:
101.1 Title. This regulation shall be known as the Glendale Fire Code, may be cited as such and will be referred to herein as "this code".
Section 104.7.6 is hereby deleted and replaced with the following:
104.7.6 Fees. The fire chief is authorized to collect fees for all inspections or operational services authorized by the code for the city of Glendale or the Glendale fire code. Permit and inspection fees, and other operational fees of the fire department may be determined by the fire chief or their designee and established by resolution.
Section 105.5.34 is hereby amended as follows:
105.5.34 Mobile Food Unit. Mobile food units shall not be required to obtain a special permit that is not required for other mobile vending businesses. Mobile food units are required to be inspected by a city or town fire department before operation.
Exception: If the mobile food vendor provides evidence that the mobile food unit passed a fire inspection by another city or town fire department in this state within the preceding twelve months.
Section 113.4 is hereby amended to read as follows:
113.4 Violation Penalties. Persons who shall violate a provision of this Code or shall fail to comply with any of the requirements thereof or who shall erect, install, alter, repair or do work in violation of the approved construction documents or directive of the fire code official, or of a permit or certificate used under provisions of this Code, shall be guilty of a Class 1 misdemeanor and punishable as a Class 1 misdemeanor under state law.
Section 114.4 is hereby amended to read as follows:
114.4 Failure to Comply. Any person who shall continue any work after having been served with a stop work order, except such work as that person is directed to perform to remove a violation or unsafe condition, shall be assessed a fee in accordance with the fees established by council resolution for operating without a permit.
Section 903.2.13 is hereby added to read as follows:
903.2.13 New and Existing Building with Unknown Occupancy or Hazard Classification. Where new or existing buildings are constructed or remodeled with an interior ceiling/deck height exceeding 20 feet (6,096 mm) and the occupancy or hazard classification is unknown, the minimum fire sprinkler design density criteria shall be .495/2000 square feet.
Section 1103.5.3 is hereby amended to read as follows:
1103.5.3 Group I-2, Condition 2. In addition to the requirements of section 1103.5.2, existing buildings of I-2, Condition 2 occupancy shall be equipped throughout with an approved automatic fire sprinkler system in accordance with section 903.3.1.1. The automatic fire sprinkler system shall be installed within 12 months of written notification.
Example Group 2, Conditions 2 occupancies include: Facilities that provide nursing and medical care and could provide emergency care, surgery, obstetrics, or inpatient stabilization units for psychiatric or detoxification, including, but not limited to hospitals.
(Ord. No. O25-52, § 1, 12-9-25)