Sec. 78-122. - Specific standards.

(a) In all areas within Orleans Parish, the following provisions are required to ensure the required minimum elevation as established by this article are met: (1) Residential construction. New construction and substantial improvement of any residential structure shall have the lowest floor (including basement) elevated to the required minimum elevation as established by this article. A registered professional engineer, architect, or land surveyor shall submit a certification to the director that the standard of this subsection is satisfied prior to issuance of a certificate of occupancy. (2) Nonresidential construction. New construction and substantial improvements of any commercial, industrial or other nonresidential structure shall either have the lowest floor (including basement) elevated to or above the required minimum elevation or, together with attendant utility and sanitary facilities, be designed so that any area below the required minimum elevation of this article is flood-proofed, with walls substantially impermeable to the passage of water and with structural components having the capability of resisting hydrostatic and hydrodynamic loads and the effect of buoyancy. A registered professional engineer or architect shall develop and/or review structural design, specifications and plans for the construction, and shall certify that the design and methods of construction are in accordance with accepted standards of practice as outlined in this subsection prior to issuance of a certificate of occupancy. A record of such certification which includes the specific elevation (in relation to mean sea level) to which such structures are flood-proofed shall be maintained by the director. (3) Enclosure. New construction and substantial improvements with fully enclosed areas below the lowest floor that are subject to flooding shall be designed to automatically equalize hydrostatic flood forces on exterior walls by allowing for the entry and exit of floodwaters. Designs for meeting this requirement must either be certified by a registered professional engineer or architect or meet or exceed the following minimum criteria: i. A minimum of two openings having a total net area of not less than one square inch for every square foot of enclosed area subject to flooding shall be provided. ii. The bottom of all openings shall be no higher than one foot above grade. iii. Openings may be equipped with screens, louvers, valves or other coverings or devices provided that they permit the automatic entry and exit of floodwaters.

(M.C.S., Ord. No. 26906, § 1, 5-5-16, eff. 6-1-16)

Ask a question about New Orleans law

Corpus searches the New Orleans sections it holds and shows the ones that match, with their citations. Free, no sign-in.