§ 56-52 — Crossings
Denver Revised Municipal Code (Supp. No. 147, Update 3: codified through Ordinance No. 0852-26, enacted July 13, 2026) · Denver Revised Municipal Code § 56-52
Corpus is an independent public-information project, not the official City of Denver website. Stable reference: corpuslaw.us/code/80e90dfb-f8af-4406-9a2b-5784449702d7
Sec. 56-52. - Crossings.
(a) Water service pipe on top. Where crossings are necessary, in such instances that the water service pipe can be placed above the building sewer or private sewer, a vertical distance of eighteen (18) inches, measured from the perimeters of the pipes, shall separate the two (2) pipes, and the crossings shall preferably be made at right angles. (b) Sewer on top. Where crossings are necessary and the water service pipe must pass below the building sewer or private sewer, the water service pipe shall be protected by one (1) of the following alternative methods: (1) The water service pipe shall be at least three (3) feet below the building sewer or private sewer, measured from the perimeters of the pipes, and an impermeable curved asphalt mat shall be laid over the water service pipe. Such mat shall be six (6) feet in width and shall protect every portion of the water service pipe within a horizontal distance of ten (10) feet of any point of the building sewer or private sewer. (2) The water service pipe shall be at least three (3) feet below the building sewer or private sewer, measured from the perimeters of the pipes, and every portion of the building sewer or private sewer within a horizontal distance of ten (10) feet from any point on the water service pipe shall be ductile iron or cast iron.
(Code 1950, § 338.22; Ord. No. 78-87, §§ 10, 11, 2-9-87)
Ask a question about Denver law
Corpus searches the Denver sections it holds and shows the ones that match, with their citations. Free, no sign-in.