§ 59.160 — Ventilation requirements

Salem Revised Code, City of Salem, Oregon (Supp. No. 26: codified through Ordinance No. 10-26, adopted August 10, 2026) · Salem Revised Code § 59.160

Corpus is an independent public-information project, not the official City of Salem website. Stable reference: corpuslaw.us/code/82d9cdb8-ddd2-405f-881d-14fe2183e2f2

Sec. 59.160. - Ventilation requirements.

(a) Except where another approved ventilation device is provided, the total openable window area in every habitable room shall be equal to at least 2.5 percent of the area of the room. The glazed areas need not be openable where the opening is not required for emergency escape and an approved mechanical ventilation system is provided capable of producing 0.35 air changes per hour in the room. (b) Every bathroom or toilet room or compartment shall comply with the light and ventilation requirements for habitable rooms as required by this chapter, except that no window shall be required in bathrooms or toilet compartments equipped with an approved ventilation system. (c) All windows within ten feet of the exterior grade that open must be able to be securely latched from the inside as well as be openable from the inside without the use of a key or any special knowledge or effort. This same requirement shall apply to all openable windows that face other locations that are easily accessible from the outside, such as balconies or fire escapes, regardless of height from the exterior grade. (d) Every window shall be substantially weather-tight, shall be kept in sound condition and repair for its intended use, and shall comply with the following: (1) Every window sash shall be fully supplied with glass windowpanes or an approved substitute without open cracks and holes. (2) Every window sash shall be in good condition and fit weathertight within its frames. (3) Every window frame shall be constructed and maintained in relation to the adjacent wall construction so as to exclude rain as completely as possible and to substantially exclude wind from entering the dwelling unit. (4) Every window shall be capable of being easily opened and held open by window hardware alone. (e) Mechanical clothes drying shall be: (1) Properly installed, connected, and maintained in safe condition and good working order; (2) Exhaust hoses must be free from leaks and obstructions and kept functioning properly so as to be free from fire, health, and accident hazards.

(Prior Code, § 59.160; Ord. No. 30-13)

Ask a question about Salem law

Corpus searches the Salem sections it holds and shows the ones that match, with their citations. Free, no sign-in.