§ 171.11.06. - Plumbing standards and regulations.
(a) Water efficient fixtures required. Water efficient plumbing fixtures or other water use mechanicals shall be installed in new construction or remodeling projects which begin after June 1, 1990. The maximum design water usage of plumbing fixtures shall be as follows: (1) All water closets, both tank and flushometer, operated by 3.5 gallons per flush or less. (2) All shower heads three gallons per minute or less. (3) All kitchen sink faucets and replacement aerators 2.5 gallons per minute or less. (4) All lavatory faucets and replacement aerators two gallons per minute or less. (b) Examples of water service fixture load calculations based on the Illinois State Plumbing Code, section 890.1210, Design of Building Water Distribution Systems. (1) Apartment, single bath and kitchen No. | Fixture | Load 1 | W.C. | 3 = | 3 1 | Lav. | 1 = | 1 1 | Kit. sink | 2 = | 2 1 | Tub. | 2= | 2 Total | 8 (2) 8 WSFU on Table N = ¾" Supply + ⅝" meter (3) Single-family residence, two bath with kitchen and dishwasher No. | Fixture | Load 2 | W.C. | 3 = | 6 2 | Lav. | 1 = | 2 1 | Kit. sink | 2 = | 2 1 | Dishwasher | 1 = | 1 2 | Tubs. | 2 = | 4 1 | Laundry | 2 = | 2 Total | 17 (4) (5) 17 WSFU on Table N = ¾" supply + ¾" meter (6) Single-family residence, 2½ bath with kitchen and dishwasher and washer/dryer hook up No. | Fixture | Load 3 | W.C. | 3 = | 9 3 | Lav. | 1 = | 3 1 | Kit. sink | 2 = | 2 1 | Dishwasher | 1 = | 1 2 | Tubs | 2 = | 4 1 | Washer hookup | 2 = | 2 Total | 21 (7) 21 WSU on Table N = 1" supply + ¾" meter (8) Single-family residence, 2½ bath with kitchen and dishwasher and wash/dryer hookup and ½ bath rough-in in basement No. | Fixture | Load 4 | W.C. | 3 = | 12 4 | Lav. | 1 = | 4 1 | Kit. sink | 2 = | 2 1 | Dishwasher | 1 = | 1 2 | Tubs | 2 = | 4 1 | Washer hookup | 2 = | 2 Total | 25 (9) 25 WSFU on Table N = 1" supply + ¾" meter (10) Single-family residence, 3½ bath with kitchen and dishwasher and washer/dryer hook up and ½ bath rough-in in basement No. | Fixture | Load 5 | W.C. | 3 = | 15 5 | Lav. | 1 = | 5 1 | Kit. sink | 2 = | 2 1 | Dishwasher | 1 = | 1 3 | Tubs | 2 = | 6 1 | Washer hookup | 2 = | 2 Total | 31 (11) 31 WSFU on table N=1" supply + 1" meter (12) Single-family residence - 4½ bath with kitchen and dishwasher and washer/dryer hook up and ½ bath rough-in in basement. No. | Fixture | Load 6 | W.C. | 3 = | 18 6 | Lav. | 1 = | 6 1 | Kit. sink | 2 = | 2 1 | Dishwasher | 1 = | 1 4 | Tubs | 2 = | 8 1 | Washer hookup | 2 = | 2 Total | 37 (13) 37 WSFU on table N - 1¼" supply + 1" meter (c) Grease interceptors. (1) Grease interceptors must be located in an exterior location for all newly constructed food service and food preparation establishments. Grease interceptors must be sized in accordance with the Illinois Plumbing Code, but must also be a minimum of 500 gallons in size, unless a variance is applied for and granted in writing by the Springfield Metro Sanitary District. (2) During remodeling of existing structures for food service and food preparation, or for a "light" duty kitchen such as could occur in an office break room, the grease trap or separator may be located within the building if an exterior location is not possible, as determined by the building department. All interior located grease traps or separators must be sized in accordance with the Illinois State Plumbing Code, but must also be a minimum of 35 gallons in size. (d) Sillcocks or frostproof wall hydrants. All exterior sillcocks must be of the antifreeze type with integral vacuum breakers. (e) Exposed piping. No exposed piping, such as waste, water supply, or fire protection, may be located above food storage, food handling, and food processing areas. (f) Elevator pit drains and sumps. All floor drains and sump pit ejector pipes must be indirectly connected to the sanitary waste system (in accordance with the current edition of the ANSI, A-17.1, Elevator Code). (g) Sanitary ejector sump discharge pipe. All sanitary ejector sump discharge pipe must discharge into a sanitary building drain or a branch of the building drain at least one pipe size larger than the ejector pipe size. The ejector sump discharge pipe may not have any other fixture drain discharging into it, and must enter the building drain or branch of the building drain at an angle of 45 degrees or greater from the horizontal. (h) Drilling holes, cutting or notching wood members. Must be in accordance with either the International Building Code, Chapter 23; International Residential Code; Chapter 6, Wall Construction; Chapter 5, Floors; Chapter 8, Roof Ceiling; and Section P2603, Plumbing. (i) Installation and maintenance of backflow preventors. All devices installed in a plumbing piping system to protect against backflow, back pressure, and back siphonage, must be installed in an accessible location, and documentation as to the size, type, locations, and date of installation and inspection or test must be presented to the owner. A copy of this documentation must be available at the building location and a copy must be sent to the plumbing inspector's office for verification of installation, inspection, and testing. (j) In all buildings in which plumbing is installed, and which have a concrete floor slab, a basement concrete floor slab or a crawl space with a concrete floor slab, at least one trapped and vented floor drain shall be installed in each concrete floor, and shall be connected to the building drain. Garages and other unheated areas must comply with the current edition of the Illinois State Plumbing Code. (k) Installation of roof overflow drains. When roof overflow drains are required by the adopted building code (generally required for flat roofs without overflow scuppers), the roof overflow drain system shall be installed as follows: The overflow drain shall be installed two inches higher than the adjacent roof drain. The overflow roof drainage system shall have roof drains, piping, and point of discharge separate from the primary roof drain system. Discharge shall occur approximately 12" above grade through an exterior wall of the building, in a location that would normally be observed by the building occupants or maintenance personnel.
(Ord. No. 826-12-06, § 1(Exh. A), 12-19-06; Ord. No. 409-11-13, § 1(Exh. A), 11-19-13)
Ask a question about Springfield law
Corpus searches the Springfield sections it holds and shows the ones that match, with their citations. Free, no sign-in.