Section 406. Energy Rating Index Compliance Alternative
406.1 Scope. {As in IECC-R} 406.2 ERI Compliance. {As in IECC-R, subject to the following MBPS Modification} {Per MBPS Modification:} Exception 1: Supply and return ducts not completely inside the building thermal envelope must be insulated to an R-value of not less than R-6. Exception 2: The maximum of 5 air changes per hour tested in accordance with § 402.4.1.2 may be used to determine the Energy Rating index score with baseline of 3 air changes per hour in climate zones 4 and 5 maintained for ERI Reference Design.
(Ord. 24-341 Section 1.)