§ 5-6-8 — Inspections
Code of Ordinances, City of Biloxi, Mississippi (Supp. No. 63, Update 1: codified through Ordinance No. 2607, enacted July 28, 2026) · Biloxi Code of Ordinances § 5-6-8
Corpus is an independent public-information project, not the official City of Biloxi website. Stable reference: corpuslaw.us/code/849fd658-46e9-4039-9a47-f3491f657d87
Sec. 5-6-8. - Inspections.
(a) Rough piping inspection. Rough piping inspection shall be made after all new piping authorized by the permit issued under this article has been installed, and before any such piping has been covered or concealed or any fixtures or gas appliances have been attached thereto. (b) Final piping inspection. Final piping inspection shall be made after all piping authorized by the permit has been installed and after all portions thereof which are to be concealed by plastering or otherwise have been so concealed, and before any fixtures or gas appliances have been attached thereto. This inspection shall include a pressure test, at which time the piping shall stand an air pressure equal to not less than the pressure of a column of mercury 12 inches in height, and the piping shall hold this air pressure for a period of 15 minutes without any perceptible drop. A mercury column gauge shall be used for the test. All tools, apparatus, labor and assistance necessary for the tests shall be furnished by the installer of such piping.
(Code 1959, § 6-87)