SEC. 10-511205.1. - SOLAR PHOTOVOLTAIC POWER SYSTEMS.
1205.1 General. Solar photovoltaic (PV) systems shall be installed in accordance with the California Building Code or California Residential Code, and the Fresno Municipal Code, including for Group R-3 and one- and two-family dwellings. The electrical portion of solar PV systems shall be installed in accordance with the California Electrical Code. Rooftop-mounted solar photovoltaic systems shall be installed in accordance with Sections 1205.2 through 1205.4.3. Ground-mounted solar photovoltaic systems shall comply with Section 1205.5 1205.2.1. Section deleted and reserved. 1205.2.1.1 Pathways to ridge. Not fewer than two 36-inch-wide (914 mm) pathways on separate roof planes, from lowest roof edge to ridge, shall be provided on all buildings. Not fewer than one pathway shall be provided on the street or driveway side of the roof. For each roof plane with a photovoltaic array, not fewer than one 36-inch-wide (914 mm) pathway from lowest roof edge to ridge shall be provided on the same roof plane as the photovoltaic array, on an adjacent roof plane. 1205.2.1.2 Setbacks at ridge. All photovoltaic arrays shall have a minimum 36 in. (914 mm) wide setback on both sides of a horizontal ridge. 1205.2.1.3 Section deleted and Reserved. 1205.2.3 Building-integrated photovoltaic (BIPV) systems. Where building-integrated photovoltaic (BIPV) systems are installed in a manner that creates areas with electrical hazards to be hidden from view, approved markings shall be provided to identify the hazardous areas to avoid for ladder placement. The markings shall be reflective and be visible from grade as required by the fire code official. Exception: BIPV systems listed in accordance with UL 3741, where the removal or cutting away of portions of the BIPV system during fire-fighting operations have been determined to not expose a firefighter to electrical shock hazards. 1205.4.1.3 Disconnecting Equipment. All photovoltaic solar power system disconnecting means, including rapid shutdown equipment, shall be indicating, of an approved size and type, and shall be placed in an approved position that is plainly visible to approaching fire department personnel. COMBUSTIBLE DUST-PRODUCING OPERATIONS
(Added Ord. 2025-039, § 3, eff. 10-31-25).
Ask a question about Fresno law
Corpus searches the Fresno sections it holds and shows the ones that match, with their citations. Free, no sign-in.